Search NASA⌕ Search

Engineering topics

Baker, K L

Publications and source records attributed to Baker, K L.

At least 19 records

Single line-of-sight dual energy backlighter for mix width experiments

We present a diagnostic technique used to spatially multiplex two x-ray radiographs of an object onto a detector along a single line-of-sight. This technique uses a thin, <2 μm, cosputtered backlighter target to simultaneously produce both Ni and Zn He{sub α} emission. A Ni picket fence filter, 500 μm wide bars and troughs, is then placed in front of the detector to pass only the Ni He{sub α} emission in the bar region and both energies in the trough region thereby spatially multiplexing the two radiographs on a single image. Initial experimental results testing the backlighter spectrum are presented along with simulated images showing the calculated radiographic images though the nickel picket fence filter which are used to measure the mix width in an accelerated nickel foam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-state framing camera with multiple time frames

A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.

36 MATERIALS SCIENCE↗

Ultrafast semiconductor x-ray detector

The National Ignition Campaign has the goal of developing a burning plasma platform producing up to {approx}10{sup 19} neutrons in {approx}20 picoseconds, ps. Diagnosis will require instruments operating with a time resolution of a few ps within this extremely large neutron flux environment. A diagnostic, which performs an ultrafast conversion of the x-ray signals into the optical regime, has been developed using a linearly chirped probe beam to measure the temporal history of the x-ray pulse. This diagnostic technique was tested on a laser-produced x-ray source and obtained a measurement of the full-width-at-half-maximum, FWHM, of the x-ray pulse of {approx}7.2 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray bang-time and fusion reaction history at ~ps resolution using RadOptic detection

We report recent progress in the development of RadOptic detectors, radiation to optical converters, that rely upon x-ray absorption induced modulation of the optical refractive index of a semiconductor sensor medium to amplitude modulate an optical probe beam. The sensor temporal response is determined by the dynamics of the electron-hole pair creation and subsequent relaxation in the sensor medium. Response times of a few ps have been demonstrated in a series of experiments conducted at the LLNL Jupiter Laser Facility. This technology will enable x-ray bang-time and fusion burn-history measurements with {approx} ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗