Baker, Stuart A.

Publications and source records attributed to Baker, Stuart A..

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Optical Relays for Imaging Scintillators

Presentation at the "Multi-Probe Radiography IV: Detectors and Image Analysis" workshop, to be held at LANL, in the Rosen Auditorium. Host is Bob Reinovsky, LANL, 505-699-1127. LANL Point of Contact: Mariana Alvarado Alvarez, LANL, 505-665-7994.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

New Optical Designs for Radiation Imaging Systems [Slides]

Presentation to be presented during the first annual Prompt Radiation Detection and Imaging Workshop, hosted by the NNSS Dynamic Instruments Team, April 25–28, 2022, at NLV C-01 Auditorium and via Webex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance

Often only a single physical process or component is investigated in the simulation of radiation detector systems. The results are then considered to be representative of what is expected in the correlating physical experiment. Although singular assessments may serve as a good estimate, the overall performance of a radiation detector system depends on several physical processes and the performance of all components within the system. Our Geant4-based multiphysics simulation toolkit couples radiation transport with optical photon processes, providing simulations of radiation detector systems components from the scintillator through the photocathode of the photodetector. Work to incorporate the back-end detector components, including the complete photodetector and subsequent electronics (e.g., amplifiers, digitizers), is underway. Geant4 is used to model the radiation transport and optical photon processes that occur in the front-end detector system components when exposed to a chosen source. These components include the scintillator, detector housing, optical coupling to the photodetector, and photocathode of the photodetector. Characteristics of several detector systems that have been studied include time response; pulse height spectra; number of photoelectrons per MeV; detector efficiency versus incident quanta energy; and effects on detector response due to change in geometries, materials, and reflectivity. Comparison of these characteristics by means of this toolkit enables the selection of the optimal individual components; thus, it is possible to specify the radiation detector system best suited to meet the requirements of any physical experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNP Estimate of ZLS Lens Sensitivity in an X-Ray Field

The telecentric zoom lens system (ZLS) has proven to be invaluable in flash x-ray field operations and recent successful experiments pertaining to stockpile stewardship. The ZLS contains 11 custom-manufactured lenses, a turning mirror (pellicle), and an x-ray-to-visible-light converting scintillator. Images are recorded on a fully characterized CCD. All hardware is supported by computerized, programmable, electro-mechanical mounts and alignment apparatus. Seven different glass material types varying in chemical stoichiometry comprise the 11 ZLS lenses. All lenses within the ZLS are out of the path of direct x-ray radiation during normal operation. However, any unshielded scattered x-ray radiation can result in energy deposition into the lenses, which may generate some scintillating light that can couple into the CCD. This extra light may contribute to a decrease in signal-to-noise ratio (SNR) and lower the overall fidelity of the radiograph images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNP Estimate of ZLS Lens Sensitivity in an X-Ray Field

The telecentric zoom lens system (ZLS) has proven to be invaluable in flash x-ray field operations and recent successful experiments pertaining to stockpile stewardship. The ZLS contains 11 custom-manufactured lenses, a turning mirror (pellicle), and an x-ray-to-visible-light converting scintillator. Images are recorded on a fully characterized CCD. All hardware is supported by computerized, programmable, electro-mechanical mounts and alignment apparatus. Seven different glass material types varying in chemical stoichiometry comprise the 11 ZLS lenses. All lenses within the ZLS are out of the path of direct x-ray radiation during normal operation. However, any unshielded scattered x-ray radiation can result in energy deposition into the lenses, which may generate some scintillating light that can couple into the CCD. This extra light may contribute to a decrease in signal-to-noise ratio (SNR) and lower the overall fidelity of the radiograph images. An estimate of the scintillation generation and sensitivities for each of the seven types of glass used as lenses in the ZLS is presented. This report also includes estimates of the total observed background decoupling that each of the lens material types contribute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗