Publications and source records attributed to Baker, Tracy J..

Optical constants measurements of liquids for modeling aerosolized threats

Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.

Lockwood, Schuyler↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

A method for generating quantitative vapor-phase infrared spectra of solids: results for phenol, camphor, menthol, syringol, dicyclopentadiene and naphthalene

Here, a method is presented to generate quantitative vapor-phase infrared spectra from substances that naturally occur as solids with moderate volatility. The solid is gravimetrically dissolved into a solvent that has few infrared spectral features, typically CS 2 and CCl 4 separately. The solution is flowed at a constant rate from a linearly pumped syringe into a metered stream of nitrogen carrier gas regulated by a mass flow controller. The analyte/solvent mix is flash vaporized by volatilizing the solution across a heated stainless-steel surface as it emanates from the syringe tip. The N 2 gas-solution mixture is flowed into a long-path White cell thermostatted at a desired temperature, the long optical path compensating for the modest analyte mixing ratio. A composite spectrum is generated from typically ten or more 760-Torr pressure-broadened spectra over the 600 to 6500 cm -1 spectral range at 0.1 cm -1 spectral resolution. The solid analytes reported here using this novel technique include dicyclopentadiene, menthol, syringol, phenol, camphor, and naphthalene.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygenate Onboard Separation for Octane-on-Demand

This project further examines the use of Self-Assembled Monolayers on Mesoporous Supports ® SAMMS ® -based sorbent materials as a sorbent for alcohols from alcohol-gasoline blends in the context of an onboard separation approach for use in an octane-on-demand strategy. Several questions were posed by potential industry collaborators seeking to better understand how the SAMMS®-based materials would perform in a more realistic environment. Several conclusions can be made from the work conducted here, with the caveat that these experiments do not represent the results that would be obtained from continuous or long-term use of the sorbent, because of the short duration of the project. Vigorous extractions into warm gasoline did not reveal the presence of additional species in gas chromatographic analysis. Vibration testing for up to eight hours under aggressive conditions did not show particle attrition. Thermal desorption experiments showed that the SAMMS ® have a higher capacity for methanol, approximately 50 weight-percent of the sorbent, than for ethanol, approximately 20 weight-percent of the sorbent, and that the methanol is easier to extract. Testing of the A20 fuel blends was insufficient and requires a slightly more sophisticated approach than was attempted here. Additionally, further work would be needed to assess the rate at which the alcohol is absorbed into the sorbent. The testing conducted here suggests that equilibrium is reached in well under an hour. While this study provides additional insights into the use of SAMMS®-based sorbent materials for onboard alcohol separation, there is room for further work employing a benchtop testing apparatus similar to that described herein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗