Search NASA⌕ Search

Engineering topics

Baldwin, Charles A.

Publications and source records attributed to Baldwin, Charles A..

At least 19 records

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Restructuring in high burnup UO 2 studied using modern electron microscopy

Modern electron microscopy techniques were used to conduct a thorough study of an irradiated urania fuel pellet microstructure to attempt at an understanding of high burnup structure formation in this material. The fuel was irradiated at low power to high burnups in a light water reactor, proving ideal for this purpose. Examination of grain size and orientation with strict spatial selectivity across the fuel pellet radius allowed for capturing the progression of the restructuring process, from its onset to full completion. Based on this information, the polygonization mechanism was shown to be responsible for restructuring, involving formation of low-angle grain boundaries with their initiation occurring at the original high-angle grain boundaries of the as-fabricated pellet and at the gas bubble-matrix interfaces. As a result, the low-angle character of boundaries between the subdivided grains disappeared in the fully developed high burnup structure, likely due to creep deformation in the pellet.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-2 Safety-Tested UCO Compact 6-4-2 PIE Report

As discussed in a previous report [Hunn et al. 2016] and reproduced in the following four paragraphs to provide background information and common terminology, post-irradiation examination (PIE) is being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2) [Collin 2014]. This effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-2 As-Irradiated UCO Compact 5-4-2 PIE Report

As discussed in a previous report [Hunn et al. 2016] and reproduced in the following three paragraphs to provide background information and common terminology, post-irradiation examination (PIE) is being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2) [Collin 2014]. This effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Local atomic structure of Pd and Ag in the SiC containment layer of TRISO fuel particles fissioned to 20% burn-up

The structure and speciation of fission products within the SiC barrier layer of tristructural-isotropic (TRISO) fuel particles irradiated to 19.6% fissions per initial metal atom (FIMA) burnup in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) was investigated. As-irradiated fuel particles, as well as those subjected to simulated accident scenarios, were examined. The TRISO particles were characterized using synchrotron X-ray absorption fine-structure spectroscopy (XAFS) at the Materials Research Collaborative Access Team (MRCAT) beamline at the Advanced Photon Source. The TRISO particles were produced at Oak Ridge National Laboratory under the Advanced Gas Reactor Fuel Development and Qualification Program and sent to the ATR for irradiation. XAFS measurements on the palladium and silver K-edges were collected using the MRCAT undulator beamline. Analysis of the Pd edge indicated the formation of palladium silicides of the form Pd x Si (2 ≤ x ≤ 3). In contrast, Ag was found to be metallic within the SiC shell safety tested to 1700 °C. To the best of our knowledge, this is the first result demonstrating metallic bonding of silver from fissioned samples. Knowledge of these reaction pathways will allow for better simulations of radionuclide transport in the various coating layers of TRISO fuels for next generation nuclear reactors. In conclusion, they may also suggest different ways to modify TRISO particles to improve their fuel performance and to mitigate potential fission product release under both normal operation and accident conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial examination of fuel compacts and TRISO particles from the US AGR-2 irradiation test

Post-irradiation examination was completed on two as-irradiated compacts from the US Advanced Gas Reactor Fuel Development and Qualification Program’s second irradiation test. These compacts were selected for examination because there were indications that they may have contained particles that released cesium through a failed or defective SiC layer. The coated particles were recovered from these compacts by electrolytic deconsolidation of the surrounding graphitic matrix in nitric acid. The leach-burn-leach (LBL) process was used to dissolve and analyze exposed metallic elements (actinides and fission products), and each particle was individually surveyed for relative cesium retention with the Irradiated Microsphere Gamma Analyzer (IMGA). Data from IMGA and LBL examinations provided information on fission product release during irradiation and whether any specific particles had below-average retention that could be related to coating layer defects or radiation-induced degradation. A few selected normal-retention particles and six with abnormally-low cesium inventory were analyzed using X-ray tomography to produce three-dimensional images of the internal coating structure. Four of the low-cesium particles had obviously damaged or degraded SiC, and X-ray imaging was able to guide subsequent grinding and polishing to expose the regions of interest for analysis by optical and electron microscopy. Additional particles from each compact were also sectioned and examined to study the overall radiation-induced microstructural changes in the kernel and coating layers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial results from safety testing of US AGR-2 irradiation test fuel

Two cylindrical compacts containing tristructural isotropic (TRISO)-coated particles with kernels that contained a mixture of uranium carbide and uranium oxide (UCO) and two compacts with UO 2 -kernel TRISO particles have undergone 1600°C safety testing. These compacts were irradiated in the US Advanced Gas Reactor Fuel Development and Qualification Program's second irradiation test (AGR-2). The time-dependent releases of several radioisotopes ( 110m Ag, 134 Cs, 137 Cs, 154 Eu, 155 Eu, 90 Sr, and 85 Kr) were monitored while heating the fuel specimens to 1600°C in flowing helium for 300 h. The UCO compacts behaved similarly to previously reported 1600°C-safety-tested UCO compacts from the AGR-1 irradiation. No failed TRISO or failed SiC were detected (based on krypton and cesium release), and cesium release through intact SiC was very low. Release behavior of silver, europium, and strontium appeared to be dominated by inventory originally released through intact coating layers during irradiation but retained in the compact matrix until it was released during safety testing. Both UO 2 compacts exhibited cesium release from multiple particles whose SiC failed during the safety test. Europium and strontium release from these two UO 2 compacts appeared to be dominated by release from the particles with failed SiC. Silver release was characteristically like the release from the UCO compacts in that an initial release of the majority of silver trapped in the matrix occurred during ramping to 1600°C. However, additional silver release was observed later in the safety testing due to the UO 2 TRISO with failed SiC. Failure of the SiC layer in the UO 2 fuel appears to have been dominated by CO corrosion, as opposed to the palladium degradation observed in AGR-1 UCO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Testing of AGR-2 UCO Compacts 6-4-2 and 2-3-1

Post-irradiation examination (PIE) and elevated-temperature safety testing are being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2). Details on this irradiation experiment have been previously reported [Collin 2014]. The AGR-2 PIE effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial examination of fuel compacts and triso particles from the US AGR-2 irradiation test - 18443

Post-irradiation examination was completed on two as-irradiated compacts from the US Advanced Gas Reactor Fuel Development and Qualification Program's second irradiation test. These compacts were selected for examination due to indications that they may have contained particles that released cesium due to a failed or defective SiC layer. The coated particles were recovered from these compacts by electrolytic deconsolidation of the surrounding graphitic matrix in nitric acid. The leach-burn-leach (LBL) process was used to dissolve and analyze exposed metallic elements (actinides and fission products), and each particle was individually surveyed for relative cesium retention with the Irradiated Microsphere Gamma Analyzer (IMGA). Data from IMGA and LBL examinations provided information on fission product release during irradiation and whether any specific particles had below-average retention that could be related to coating layer defects or radiation-induced degradation. A few selected normal-retention particles and six with abnormally-low cesium inventory were analyzed using x-ray tomography to produce three-dimensional images of the internal coating structure. Four of the low-cesium particles had obviously damaged or degraded SiC, and x-ray imaging was able to guide subsequent grinding and polishing to expose the regions of interest for analysis by optical and electron microscopy. Additional particles from each compact were also sectioned and examined to study the overall radiation-induced microstructural changes in the kernel and coating layers. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial results from safety testing of US AGR-2 irradiation test fuel - 18574

Two cylindrical compacts containing tri-structural isotropic (TRISO)-coated particles with kernels that contained a mixture of uranium carbide and uranium oxide (UCO) and two compacts with UO{sub 2}-kernel TRISO particles have undergone 1600 deg. C safety testing. These compacts were irradiated in the US Advanced Gas Reactor Fuel Development and Qualification Program's second irradiation test (AGR-2). The time-dependent releases of several radioisotopes ({sup 110m}Ag, {sup 134}Cs, {sup 137}Cs, {sup 154}Eu, {sup 155}Eu, {sup 90}Sr, and {sup 85}Kr) were monitored while heating the fuel specimens to 1600 deg. C in flowing helium for 300 h. The UCO compacts behaved similarly to previously reported 1600 deg. C-safety-tested UCO compacts from the AGR-1 irradiation. No failed TRISO or failed SiC were detected (based on krypton and cesium release), and cesium release through intact SiC was very low. Release behavior of silver, europium, and strontium appeared to be dominated by inventory originally released through intact coating layers during irradiation but retained in the compact matrix until it was released during safety testing. Both UO{sub 2} compacts exhibited cesium release from multiple particles whose SiC failed during the safety test. Europium and strontium release from these two UO{sub 2} compacts appeared to be dominated by release from the particles with failed SiC. Silver release was characteristically similar to the release from the UCO compacts in that an initial release of the majority of silver trapped in the matrix occurred during ramping to 1600 deg. C. However, additional silver release was observed later in the safety testing due to the UO{sub 2} TRISO with failed SiC. Failure of the SiC layer in the UO{sub 2} fuel may have been dominated by CO corrosion, as opposed to the palladium degradation observed in AGR-1 UCO fuel. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of silver release predictions using PARFUME with results from the AGR-2 irradiation experiment - 18579

The PARFUME (Particle Fuel Model) code was used to predict silver release from tri-structural isotropic (TRISO) coated fuel particles and compacts during the second irradiation experiment (AGR-2) of the Advanced Gas Reactor Fuel Development and Qualification program. The PARFUME model for the AGR-2 experiment used the fuel compact volume average temperature for each of the 559 days of irradiation to calculate the release of fission product silver from a representative particle for a select number of AGR-2 compacts and individual fuel particles containing either mixed uranium carbide/oxide (UCO) or 100% uranium dioxide (UO{sub 2}) kernels. Post-irradiation examination (PIE) measurements were performed to provide data on release of silver from these compacts and individual fuel particles. The available experimental fractional releases of silver were compared to their corresponding PARFUME predictions. Preliminary comparisons show that PARFUME under-predicts the PIE results in UCO compacts and is in reasonable agreement with experimental data for UO{sub 2} compacts. The accuracy of PARFUME predictions is impacted by the code limitations in the modeling of the temporal and spatial distributions of the temperature across the compacts. Nevertheless, the comparisons on silver release lie within the same order of magnitude. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of silver release predictions using PARFUME with results from the AGR-2 irradiation experiment

The PARFUME (PARticle FUel ModEl) code was used to predict silver release from tristructural isotropic (TRISO) coated fuel particles and compacts during the second irradiation experiment (AGR-2) of the Advanced Gas Reactor Fuel Development and Qualification program. The PARFUME model for the AGR-2 experiment used the fuel compact volume average temperature for each of the 559 days of irradiation to calculate the release of fission product silver from a representative particle for a select number of AGR-2 compacts and individual fuel particles containing either mixed uranium carbide/oxide (UCO) or 100% uranium dioxide (UO2) kernels. Post-irradiation examination (PIE) measurements were performed to provide data on release of silver from these compacts and individual fuel particles. The available experimental fractional releases of silver were compared to their corresponding PARFUME predictions. Preliminary comparisons show that PARFUME under-predicts the PIE results in UCO compacts and is in reasonable agreement with experimental data for UO2 compacts. The accuracy of PARFUME predictions is impacted by the code limitations in the modeling of the temporal and spatial distributions of the temperature across the compacts. Nevertheless, the comparisons on silver release lie within the same order of magnitude.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Testing of AGR-2 UCO Compacts 5-2-2, 2-2-2, and 5-4-1

Post-irradiation examination (PIE) is being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2). This effort builds upon the understanding acquired throughout the AGR-1 PIE campaign, and is establishing a database for the different AGR-2 fuel designs. The AGR-2 irradiation experiment included TRISO fuel particles coated at BWX Technologies (BWXT) with a 150-mm-diameter engineering-scale coater. Two coating batches were tested in the AGR-2 irradiation experiment. Batch 93085 had 508-μm-diameter uranium dioxide (UO 2 ) kernels. Batch 93073 had 427-μm-diameter UCO kernels, which is a kernel design where some of the uranium oxide is converted to uranium carbide during fabrication to provide a getter for oxygen liberated during fission and limit CO production. Fabrication and property data for the AGR-2 coating batches have been compiled and compared to those for AGR-1. The AGR-2 TRISO coatings were most like the AGR-1 Variant 3 TRISO deposited in the 50-mm-diameter ORNL lab-scale coater. In both cases argon-dilution of the hydrogen and methyltrichlorosilane coating gas mixture employed to deposit the SiC was used to produce a finer-grain, more equiaxed SiC microstructure. In addition to the fact that AGR-1 fuel had smaller, 350-μm-diameter UCO kernels, notable differences in the TRISO particle properties included the pyrocarbon anisotropy, which was slightly higher in the particles coated in the engineering-scale coater, and the exposed kernel defect fraction, which was higher for AGR-2 fuel due to the detected presence of particles with impact damage introduced during TRISO particle handling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of AGR-1 high-temperature reactor fuel during post-irradiation heating tests

The fission product retention of irradiated low-enriched uranium oxide/uranium carbide tri-structural isotropic (TRISO) fuel compacts from the Advanced Gas-Cooled Reactor 1 (AGR-1) experiment has been evaluated at temperatures of 1600–1800 °C during post-irradiation safety tests. Fourteen compacts (a total of ~58,000 particles) with a burnup ranging from 13.4% to 19.1% fissions per initial metal atom (FIMA) have been tested using dedicated furnace systems at Idaho National Laboratory and Oak Ridge National Laboratory. The release of fission products 110mAg, 134Cs, 137Cs, 154Eu, 155Eu, 90Sr, and 85Kr was monitored while heating the fuel specimens in flowing helium. The behavior of silver, europium, and strontium appears to be dominated by inventory that was originally released through intact SiC coating layers during irradiation, but was retained in the compact at the end of irradiation and subsequently released during the safety tests. However, at a test temperature of 1800 °C, the data suggest that release of these elements through intact coatings may become significant after ~100 h. Cesium was very well retained by intact SiC layers, with a fractional release <5 × 10–6 after 300 h at 1600 °C or 100 h at 1800 °C. However, it was rapidly released from individual particles if the SiC layer failed, and therefore the overall cesium release fraction was dominated by the SiC defect and failure fractions in the fuel compacts. No complete TRISO coating layer failures were observed after 300 h at 1600 or 1700 °C, and 85 Kr release was very low during the tests (particles with failed SiC, but intact outer pyrocarbon, retained most of their krypton). Krypton release from TRISO failures was only observed after ~210 h at 1800 °C in one compact. As a result, post-safety-test examination of fuel compacts and particles has focused on identifying specific particles from each compact with notable fission product release and detailed analysis of the coating layers to understand particle behavior.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection and analysis of particles with failed SiC in AGR-1 fuel compacts

As the primary barrier to release of radioactive isotopes emitted from the fuel kernel, retention performance of the SiC layer in tristructural isotropic (TRISO) coated particles is critical to the overall safety of reactors that utilize this fuel design. Most isotopes are well-retained by intact SiC coatings, so pathways through this layer due to cracking, structural defects, or chemical attack can significantly contribute to radioisotope release. In the US TRISO fuel development effort, release of 134 Cs and 137 Cs are used to detect SiC failure during fuel compact irradiation and safety testing because the amount of cesium released by a compact containing one particle with failed SiC is typically ten or more times higher than that released by compacts without failed SiC. Compacts with particles that released cesium during irradiation testing or post-irradiation safety testing at 1600–1800 °C were identified, and individual particles with abnormally low cesium retention were sorted out with the Oak Ridge National Laboratory (ORNL) Irradiated Microsphere Gamma Analyzer (IMGA). X-ray tomography was used for three-dimensional imaging of the internal coating structure to locate low-density pathways through the SiC layer and guide subsequent materialography by optical and scanning electron microscopy. In addition, all three cesium-releasing particles recovered from as-irradiated compacts showed a region where the inner pyrocarbon (IPyC) had cracked due to radiation-induced dimensional changes in the shrinking buffer and the exposed SiC had experienced concentrated attack by palladium; SiC failures observed in particles subjected to safety testing were related to either fabrication defects or showed extensive Pd corrosion through the SiC where it had been exposed by similar IPyC cracking.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIE on Safety-Tested Loose Particles from Irradiated Compact 4-4-2

Post-irradiation examination (PIE) is being performed in support of tristructural isotropic (TRISO) coated particle fuel development and qualification for High Temperature Gas-cooled Reactors (HTGRs). This work is sponsored by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Advanced Reactor Technologies (ART) Office under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program. The AGR-1 experiment was the first in a series of TRISO fuel irradiation tests initiated in 2006. The AGR-1 TRISO particles and fuel compacts were fabricated at Oak Ridge National Laboratory (ORNL) in 2006 using laboratory-scale equipment and irradiated for 3 years in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) to demonstrate and evaluate fuel performance under HTGR irradiation conditions. Post-irradiation examination was performed at INL and ORNL to study how the fuel behaved during irradiation, and to test fuel performance during exposure to elevated temperatures at or above temperatures that could occur during a depressurized conduction cooldown event. This report summarizes safety testing and post-safety testing PIE conducted at ORNL on loose particles extracted from irradiated AGR-1 Compact 4-4-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preparation of Simulated LBL Defects for Round Robin Experiment

A critical characteristic of the TRISO fuel design is its ability to retain fission products. During reactor operation, the TRISO layers act as barriers to release of fission products not stabilized in the kernel. Each component of the TRISO particle and compact construction plays a unique role in retaining select fission products, and layer performance is often interrelated. The IPyC, SiC, and OPyC layers are barriers to the release of fission product gases such as Kr and Xe. The SiC layer provides the primary barrier to release of metallic fission products not retained in the kernel, as transport across the SiC layer is rate limiting due to the greater permeability of the IPyC and OPyC layers to many metallic fission products. These attributes allow intact TRISO coatings to successfully retain most fission products released from the kernel, with the majority of released fission products during operation being due to defective, damaged, or failed coatings. This dominant release of fission products from compromised particles contributes to the overall source term in reactor; causing safety and maintenance concerns and limiting the lifetime of the fuel. Under these considerations, an understanding of the nature and frequency of compromised particles is an important part of predicting the expected fission product release and ensuring safe and efficient operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗