Search NASA⌕ Search

Engineering topics

Bandstra, M. S.

Publications and source records attributed to Bandstra, M. S..

An Ensemble Approach to Computationally Efficient Radiological Anomaly Detection and Isotope Identification

Radiological source search is a challenging task involving detection and identification of weak sources in a constantly changing radiological background. As of now, many radiological source detection algorithms have been proposed; however, their computational complexity, and hence reliance on power intensive processing units inhibit low-power applications of radiological source search systems. In this work, we introduce the anomaly filter (AF) algorithm; a computationally light, yet effective time-series source detection algorithm based on exponential weighted moving average (EWMA) and Poisson deviance statistics. Then, we demonstrate that the proposed algorithm can be used in ensemble with other more computationally intensive source detection and identification algorithms to achieve both increased detection performance and reduced power consumption. The proposed AF algorithm and the ensemble algorithms were thoroughly benchmarked against several existing source detection and identification algorithms. The results show that the AF algorithm outperforms existing conventional source detection algorithms, and the ensemble approach improves the overall performance of existing source detection and isotope identification algorithms. Furthermore, the AF algorithm and the Non-negative Matrix Factorization approach based source identification (NMF-ID) algorithm were combined and implemented on a singleboard microcontroller and the power consumption was measured. This ensemble algorithm reduced the power consumption of the NMF-ID algorithm almost by a factor of 100, while improving the detection performance of the overall system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene

We discuss using a series of detector measurements taken at different locations to localize a source of radiation as a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗