Characteristics and Influence of Biosmoke on the Fine-Particle Ionic Composition Measured in Asian Outflow during the Transport and Chemical Evolution Over the Pacific (TRACE-P) Experiment

We investigate the sources, prevalence, and fine-particle inorganic composition of biosmoke over the western Pacific Ocean between 24 February and 10 April 2001. The analysis is based on highly time-resolved airborne measurements of gaseous and fine- particle inorganic chemical composition made during the NASA Transport and Chemical Evolution over the Pacific (TRACE-P) experiment. At latitudes below approximately 25 deg. N, relatively pure biomass burning plumes of enhanced fine-particle potassium, nitrate, ammonium, light-absorbing aerosols, and CO concentrations were observed in plumes that back trajectories and satellite fire map data suggest originated from biomass burning in southeast Asia. Fine-particle water-soluble potassium (K+) is confirmed to be a unique biosmoke tracer, and its prevalence throughout the experiment indicates that approximately 20% of the TRACE-P Asian outflow plumes were influenced, to some extent, by biomass or biofuel burning emissions. At latitudes above 25 deg. N, highly mixed urban/industrial and biosmoke plumes, indicated by SO(sup 2, sub 4) and K+, were observed in 5 out of 53 plumes. Most plumes were found in the Yellow Sea and generally were associated with much higher fine-particle loadings than plumes lacking a biosmoke influence. The air mass back trajectories of these mixed plumes generally pass through the latitude range of between 34 deg. and 40 deg. N on the eastern China coast, a region that includes the large urban centers of Beijing and Tianjin. A lack of biomass burning emissions based on fire maps and high correlations between K+ and pollution tracers (e.g., S(sup 2, sub 4) suggest biofuel sources. Ratios of fine-particle potassium to sulfate are used to provide an estimate of relative contributions of biosmoke emissions to the mixed Asian plumes. The ratio is highly correlated with fine-particle volume (r(sup 2) = 0.85) and predicts that for the most polluted plume encounter in TRACE-P, approximately 60% of the plume is associated with biosmoke emissions. On average, biosmoke contributes approximately 35-40% to the measured fine inorganic aerosol mass in the mixed TRACE-P plumes intercepted north of 25% latitude.

Ma, Y.↗

Chemical Characteristics of Continental Outflow from Asia to the Troposphere Over the Western Pacific Ocean during February - March 1994: Results from PEM-West B

We present here the chemical composition of outflow from the Asian continent to the atmosphere over the western Pacific basin during the Pacific Exploratory Mission-West (PEM-West B) in February-March 1994. Comprehensive measurements of important tropospheric trace gases and aerosol particulate matter were performed from the NASA DC-8 airborne laboratory. Backward 5 day isentropic trajectories were used to partition the outflow from two major source regions- continental north (greater than 20 deg N) and continental south (less than 20 deg N). Air parcels that had not passed over continental areas for the previous 5 days were classified as originating from an aged marine source. The trajectories and the chemistry together indicated that there was extensive rapid outflow of air parcels at altitudes below 5 km, while aged marine air was rarely encountered and only at less than 20 deg N latitude. The outflow at low altitudes had enhancements in common industrial solvent vapors such as C2Cl4, CH3CCl3, and C6H6, intermixed with the combustion emission products C2H2, C2H6, CO, and NO. The mixing ratios of all species were up to tenfold greater in outflow from the continental north compared to the continental south source region, with Pb-210 concentrations reaching 38 fCi (10(exp -15) curies) per standard cubic meter. In the upper troposphere we again observed significant enhancements in combustion-derived species in the 8-10 km altitude range, but water-soluble trace gases and aerosol species were depleted. These observations suggest that ground level emissions were lofted to the upper troposphere by wet convective systems which stripped water-soluble components from these air parcels. There were good correlations between C2H2 and CO and C2H6 (r(sup 2) = 0.70 - 0.97) in these air parcels and much weaker ones between C2H2 and H2O2 or CH3OOH (r(sup 2) = 0.50). These correlations were the strongest in the continental north outflow where combustion inputs appeared to be recent (1 - 2 days old). Ozone and PAN showed general correlation in these same air parcels but not with the combustion products. It thus appears that several source inputs were intermixed in these upper tropospheric air masses, with possible contributions from European or Middle Eastern source regions. In aged marine air mixing ratios of 03 (approximately equals 20 parts per billion by volume) and PAN (less than or equal to 10 parts per trillion by volume) were nearly identical at less than 2 km and 10 - 12 km altitudes due to extensive convective uplifting of marine boundary layer air over the equatorial Pacific even in wintertime. Comparison of the Pacific Exploratory Mission-West A and PEM-West B data sets shows significantly larger mixing ratios of SO2 and H2O2 during PEM-West A. Emissions from eruption of Mount Pinatubo are a likely cause for the former, while suppressed photochemical activity in winter was probably responsible for the latter. This comparison also highlighted the twofold enhancement in C2H2, C2H6, and C3H8 in the continental north outflow during /PEM-West B. Although this could be due to reduced OH oxidation rates of these species in wintertime, we argue that increased source emissions are primarily responsible.

Talbot, R. W.↗

Advection of sulfur dioxide over the western Atlantic Ocean during CITE 3

During the NASA Chemical Instrumentation Test and Evaluation 3 sulfur intercomparison over the western Atlantic Ocean, five techniques for the determination of sulfur dioxide were evaluated. The response times of the techniques varied from 3 to 30 min. Based on the ensemble of measurements reported, it was clear that advection of SO2 from the North American continent occurred in the boundary layer (altitude less than 1 km) with only one exception. The vertical distribution of SO2 above the boundary layer for the northern and southern Atlantic Ocean was remarkably similar duing this experiment.

Thornton, D. C.↗

Electrochemical concentration cell ozonesonde accuracy and precision

This paper is concerned with the results of a study designed to evaluate experimentally the accuracy and precision of electrochemical concentration cell (ECC) ozonesondes as prepared and flown by NASA, as a function of altitude. A combination of dual-instrument soundings and laboratory work using an environmental chamber was employed in the study. The ECC ozonesonde is a small, balloon-borne sensor developed for obtaining vertical profiles of atmospheric ozone. Attention is given to the design of the employed environmental chamber, ozone and temperature profiles used in simulated ozonesonde soundings, absolute and relative ECC ozonesonde precision estimates determined with the environmental chamber and from dual-instrument balloon soundings, and the ECC ozonesonde accuracy.

Barnes, R. A.↗

Free tropospheric measurements of CS2 over a 45 deg N to 45 deg S latitude range

The mean value obtained from 52 free tropospheric measurements of CS2 over the 45 deg N-45 deg S latitude range was 5.7 pptv, with standard deviation and standard error of 1.9 and 0.3 pptv, respectively. Large fluctuations in the CS2 concentration are observed which reflect the apparent short atmospheric residence time and inhomogeneities in the surface sources of CS2. The amounts of CS2 in the Northern and Southern Hemispheres are statistically equal.

Tucker, B. J.↗

Research on atmospheric volcanic emissions - An overview

Atmospheric abundances and the geochemical cycle of certain volatile compounds and elements may be largely influenced or entirely controlled by magmatic sources. However, better estimates of the magnitude and variability of volcanic emissions are required if the importance of this natural source of atmospheric constituents and the resulting effect on atmospheric chemistry are to be elucidated. The project 'Research on Atmospheric Volcanic Emissions' (RAVE) is concerned with the improvement of knowledge of both geological and chemical phenomena attending these emissions by means of comprehensive instrumentation on board a research aircraft making simultaneous measurements of plume constituents. A description is presented of the equipment and the procedures used in the RAVE field study of Mt. St. Helens' plume. An overview of the results is also provided.

Friend, J. P.↗

Performance characteristics of the electrochemical concentration cell ozonesonde

A large number of electrochemical concentration cell (ECC) ozonesondes were calibrated in relation to a UV photometric absorption ozone instrument prior to using the ozonesondes in atmospheric soundings. The two methods of measuring ozone were in reasonable agreement on the average, but there was considerable variation from one ozonesonde to another. Averaging the individual linear regressions gives an ECC ozone concentration equal to 0 + or - 8 nbar plus (0.96 + or - 0.10) times the concentration determined with the UV instrument, where uncertainties represent 90% confidence limits. Applying individual calibration corrections to atmospheric sounding data reduced the mean difference between Dobson spectrophotometric measurements of total ozone overburdens and corresponding values obtained from ozonesonde data from -8.5 + or - 8.2 to -1.4 + or - 7.3% for a series of measurements carried out in 1977. Corresponding uncorrected and corrected differences averaged 3.2 + or - 9.7 and 1.9 + or - 10.6%, respectively, for soundings carried out in 1976.

Torres, A. L.↗

Performance evaluation of electrochemical concentration cell ozonesondes

Laboratory calibrations of more than a hundred electrochemical concentration cell (ECC) ozonesondes were determined relative to UV-photometry. The average intercept and slope, 0 plus or minus 5 nb and 0.96 plus or minus 0.06, respectively, indicate reasonable agreement with UV photometry, but with considerable variation from one ECC ozonesonde to another. The time required to reach 85% of the final reaction to a step-change in ozone concentration was found to average 51 seconds. Application of the individual calibrations to 20 sets of 1976 flight data reduced the average of the differences between ozonesonde and Dobson spectrophotometric measurements of total ozone from 3.9 to 1.3%. A similar treatment of a set of 10 1977 flight records improved the average ECC-Dobson agreement from -8.5 to -1.4%. Although systematic differences were reduced, no significant effect on the random variations was evident.

Torres, A. L.↗

Electrochemical concentration cell ozonesonde performance evaluation

A large number of electrochemical concentration cell (EDD) ozonesondes were calibrated relative to ultraviolet photometric absorption (254 nm) to determine their precision and accuracy. The average agreement with UV photometry was found to be good, but with considerable variation from one ECC ozonesonde to another. Applying individual calibrations to vertical ozone profiles reduced the systematic differences between ECC ozonesonde total ozone values and Dobson spectrophotometric determinations of the same quantity, but did not improve random differences.

Torres, A. L.↗

Ambient Atmospheric Hydrocarbon Content as Determined by Gas Chromatographic Techniques from Rural Tidewater Virginia in Late Spring 1974

In an attempt to ascertain the naturally generated hydrocarbon contribution to the air quality of the Hampton Roads region of Tidewater Virginia, a series of 27 air samples was obtained in two rural locations during late spring of 1974. These samples were analyzed for their hydrocarbon content (carbon number range C5 to C10) using gas chromatographic techniques. The thirty different hydrocarbon species were identified and monitored in the experiment. Preliminary analysis of the data indicates an average concentration of 397 parts per billion by weight (carbon) for the total non-methane hydrocarbon loading for C5 to C10 during the experiment. This value exceeds the National Primary Air Quality Standards as set by the Environmental Protection Agency.

Copeland, G. E.↗

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

Evaluation of Raman scattering as a sensor of temperature and molecular density

The performance of the Raman scattering technique for the remote monitoring of temperature and molecular number density in various wind tunnel and engine testing facilities has been experimentally evaluated. Temperature measurements were made by monitoring the pure rotational spectrum of nitrogen and the rotational branch separations of nu2 of CF4 for temperatures in the range 300 to 1000 K. These measurements yielded an average error of 2.6 and 7.6%, respectively, for temperature measurements at pressures near 1 atm. Molecular number density measurements with 20% error could be made at densities as low as 3.5 times 10 to the 22-nd power per cu m by monitoring the 6 to 8 rotational transition of nitrogen, 3.5 times 10 to the 23-rd power per cu m by monitoring the Q-branch of the fundamental vibrational transition of nitrogen, and 7 times 10 to the 22-nd power per cu m by monitoring the nu1 fundamental vibrational transition of CF4.

Bandy, A. R.↗

The application of laser-Raman light scattering to the determination of sulfate in sea and estuarine waters

Laser-Raman light scattering is a technique for determining sulfate concentrations in sea and estuarine waters with apparently none of the interferences inherent in the gravimetric and titrametric methods. The Raman measurement involved the ratioing of the peak heights of an unknown sulfate concentration and a nitrate internal standard. This ratio was used to calculate the unknown sulfate concentration from a standard curve. The standard curve was derived from the Raman data on prepared nitrate-sulfate solutions. At the 99.7% confidence level, the accuracy of the Raman technique was 7 to 8.6 percent over the concentration range of the standard curve. The sulfate analyses of water samples collected at the mouth of the James River, Hampton, Virginia, demonstrated that in most cases sulfate had a constant concentration relative to salinity in this area.

Bandy, A. R.↗

Remote detection of aerosol pollution by ERTS

The author has identified the following significant results. Photogrammetric and densitometric examination of ERTS-1 MSS imagery of eastern Virginia coupled with extensive ground truth air quality and meteorological data has shown that the identification and surveying of fixed particulate emitters (smoke plumes) is feasible. A description of the ground truth network is included. The quantitative monitoring of smoke stacks from orbital altitudes over state-size regions appears possible when tied to realistic plume models and minimal ground truth. Contrast reductions over urban areas can possibly be utilized to produce isopleths of particulates when supplemented by local measurements.

Copeland, G. E.↗

Use of ERTS imagery in air pollution and marine biology studies, tasks 1 through 3

There are no author-identified significant results in this report. The general suitability of ERTS imagery in detecting ground originated air pollution has proved to be excellent. The quality and resolution exceeded expectations and has permitted in some instances location of point sources to within a thousand feet. Suitable techniques have not yet been developed for determining or measuring area and line sources of air pollution. A major problem has been cloud cover that has persisted over the area of primary interest, the Chesapeake Bay. Work has been completed on mounting the shipboard transmissometer which will be used for investigations to relate the chlorophyll and suspended sediment content in the waters of the Lower Chesapeake Bay to ERTS-1 imagery. Water sampling, plankton analysis, and preparations for sea collection of water truth along the eastern continental shelf of the U.S. have been completed for use in comparisons with ERTS-1 data.