Solution-processable porous graphitic carbon from bottom-up synthesis and low-temperature graphitization
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Banerjee, S..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
New observations of pedestal localized turbulence in the inter-ELM period of H-mode plasmas in DIII-D show that ion temperature gradient mode scale (ITG-scale) density fluctuation (ñ) increases immediately after each ELM crash and is quickly suppressed during the increase in local E × B shear. This excitation and subsequent suppression of ITG-scale ñ can explain the previously reported anomalous ion heat flux, Qi during the ELM (Viezzer et al 2017 Nucl. Fusion 57 022020). Shorter wavelength trapped electron mode scale (TEM-scale) ñ starts to increase at a critical pedestal temperature gradient (∇Te,ped) and saturates as local E × B shear, ${T}_{\mathrm{i}}^{\mathrm{C}\mathrm{6}+}/{T}_{\mathrm{e}}$ ratio, and ∇Te,ped saturate. This TEM-scale ñ, which has the potential to cause electron (and also ion) heat transport, is consistent with driving an anomalous electron heat flux Qe, where Qe is estimated between ELMs using experimental profiles and power balance. Both ITG- and TEM-scale ñ amplitude variations with background Ti/Te and ∇ne,ped are found to be consistent with theoretical predictions of these measured density fluctuations being ITG and TEM instabilities respectively. Furthermore, these new and unique observations on the nature of turbulence and their potential contributions to electron and ion heat fluxes at different ELM periods (i.e. collapse, recovery, and saturation phases of pedestal gradients) can significantly test and improve our pedestal predictive capabilities for ITER and other future fusion devices.
Not Available
We report recent development of ultrafast measurement techniques on the sub-femtosecond time scale has enabled us to see the atom–laser interaction in real time. One of the important observables to study the temporally resolved dynamics is the various time delay in the process. Time delays is an experimentally measurable quantity, where the time is not. Time delays in quantum collisions and in photoionization/photodetachment of atomic and molecular systems is reviewed. The formalisms of time delay in the context of quantum collisions by Eisenbud and Wigner that by Smith and their equivalence is discussed. The time-reversal symmetry between solutions with outgoing and ingoing wave boundary conditions allow us to interpret photoionization/photodetachment as half-scattering. Subsequently, the formalism of Eisenbud–Wigner–Smith time delay is extended in photoionization/photodetachment from collisions. We discuss that the time delay can be written as a self-adjoint quantum operator which depicts its measurability. On the experimental side, the measurement protocols are reviewed for attosecond streaking and RABBITT. Along with the EWS time delay, the measurement introduces an additional (which is negative) time delay. From the measurement of total delay and an analytical/numerical estimate of the measurement induced part, one gets the EWS time delay in the process. A few illustrative examples of studies on time delay are given to get a flavour of the outstanding advances made in this field in the last two decades.
Lithium superionic conductors (LSCs) are of major importance as solid electrolytes for next-generation all-solid-state lithium-ion batteries. While ab initio molecular dynamics have been extensively applied to study these materials, there are often large discrepancies between predicted and experimentally measured ionic conductivities and activation energies due to the high temperatures and short time scales of such simulations. Here, we present a strategy to bridge this gap using moment tensor potentials (MTPs). We show that MTPs trained on energies and forces computed using the van der Waals optB88 functional yield much more accurate lattice parameters, which in turn leads to accurate prediction of ionic conductivities and activation energies for the Li 0·33 La 0·56 TiO 3 , Li 3 YCl 6 and Li 7 P 3 S 11 LSCs. NPT MD simulations using the optB88 MTPs also reveal that all three LSCs undergo a transition between two quasi-linear Arrhenius regimes at relatively low temperatures. This transition can be traced to an increase in the number and diversity of diffusion pathways, in some cases with a change in the dimensionality of diffusion. Furthermore, this work presents not only an approach to develop high accuracy MTPs, but also outlines the diffusion characteristics for LSCs which is otherwise inaccessible through ab initio computation.
Explore the source record for details and available documents.
As part of its HL-LHC upgrade program, the CMS collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CEE) and hadronic (CE-H) compartments. The calorimeter will be built with ~30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1 cm 2 , and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.
The low-to-high mode or L-H transition in tokamaks involves a sudden reduction in the edge turbulence level and decrease in the edge plasma transport. The mechanism for the L-H transition is widely believed to be associated changes in the the poloidal velocity of the edge turbulence. Using a gas puff imaging (GPI) diagnostic, the poloidally averaged poloidal turbulence velocity < V pol > pol was measured for a set of 16 shots with L-H transitions in NSTX. These measurements were focused -2 cm inside the separatrix where the relative fluctuation level as seen in GPI decreases significantly and consistently at the transition. Herein, the magnitude of this poloidal velocity preceding the transition varied widely, ranging from |V pol | ~1-4 km/sec during the last 1 msec before the transition, and the magnitude of the radial gradient also had a wide shot-to-shot range of |grad V pol | ~ 0.34 to 1.9 km/sec/cm during this same time. The frequency spectrum of < V pol > pol during the 30 msec before the transition had a near-coherent peak at ~2-5 kHz, but only in about half of these shots. In general, there were no clear and consistent changes in the poloidal velocity of the turbulence preceding the L-H transition in this database.
The efficiency of state-of-the-art Cd Te solar cells remains limited by the relatively low open-circuit voltage (V OC ). Improving the front interface is key towards realizing a higher V OC after achieving the necessary bulk carrier density and lifetime. Recent efforts in identifying buffer layers beyond Cd S have focused on Mg x Zn 1-x O, which offers tunability of the band offsets, but often suffers from high interfacial defect densities. Ga 2 O 3 -based buffer layers demonstrate tremendous improvements in interfacial defect passivation in crystalline silicon and dye-sensitized solar cells, leading to record high V OC , yet remain largely unexplored in Cd Te-based devices. Here, we perform hybrid density-functional-theory calculations to investigate pure Ga 2 O 3 and InGaO 3 alloys as a window layer in Cd Te photovoltaics. We report calculated band offsets for several pairs of solid-solid interfaces comprising transparent conducting oxide (TCO) and Cd Te heterojunctions. The results support a large conduction band offset spike of 0.67 eV for the Cd Te/Ga 2 O 3 (100) interface, while the offset is reduced to 0.18 eV for the InGaO 3 alloy and matches closely with the preferred optimum value of 0.2 eV. Device-level modeling tests of Cd Te solar cells integrating our results indicate that the highest efficiency is achieved with InGaO 3 acting both as a buffer layer and TCO. Finally, our results suggest that alloys of In 2 O 3 and Ga 2 O 3 may be attractive alternatives to Mg x Zn 1-x O for tailoring optimal conduction-band offsets of the buffer and TCO layers in high-efficiency Cd Te thin-film solar cells.
Explore the source record for details and available documents.
We present a study of the normalized transverse momentum distribution of W bosons produced in $p\bar{p}$ collisions, using data corresponding to an integrated luminosity of 4.35 fb -1 collected with the D0 detector at the Fermilab Tevatron collider at $\sqrt{s}$ = 1.96 TeV. The measurement focuses on the transverse momentum region below 15 GeV, which is of special interest for electroweak precision measurements; it relies on the same detector calibration methods which were used for the precision measurement of the W boson mass. The measured distribution is compared to different QCD predictions and a procedure is given to allow the comparison of any further theoretical models to the D0 data.
Full detector simulation was among the largest CPU consumers in all CERN experiment software stacks for the first two runs of the Large Hadron Collider. In the early 2010s, it was projected that simulation demands would scale linearly with increasing luminosity, with only partial compensation from increasing computing resources. The extension of fast simulation approaches to cover more use cases that represent a larger fraction of the simulation budget is only part of the solution, because of intrinsic precision limitations. The remainder corresponds to speeding up the simulation software by several factors, which is not achievable by just applying simple optimizations to the current code base. In this context, the GeantV R&D project was launched, aiming to redesign the legacy particle transport code in order to benefit from features of fine-grained parallelism, including vectorization and increased locality of both instruction and data. This paper provides an extensive presentation of the results and achievements of this R&D project, as well as the conclusions and lessons learned from the beta version prototype.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not Available