Search NASA⌕ Search

Engineering topics

Banerjee, Sunanda

Publications and source records attributed to Banerjee, Sunanda.

At least 19 records

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Simulation Challenges for Future Accelerator Experiments

Detector simulation is a key component for studies on prospective future high-energy colliders, the design, optimization, testing and operation of particle physics experiments, and the analysis of the data collected to perform physics measurements. This review starts from the current state of the art technology applied to detector simulation in high-energy physics and elaborates on the evolution of software tools developed to address the challenges posed by future accelerator programs beyond the HL-LHC era, into the 2030–2050 period. New accelerator, detector, and computing technologies set the stage for an exercise in how detector simulation will serve the needs of the high-energy physics programs of the mid 21st century, and its potential impact on other research domains.

43 PARTICLE ACCELERATORS↗

Denoising Convolutional Networks to Accelerate Detector Simulation

The high accuracy of detector simulation is crucial for modern particle physics experiments. However, this accuracy comes with a high computational cost, which will be exacerbated by the large datasets and complex detector upgrades associated with next-generation facilities such as the High Luminosity LHC. We explore the viability of regression-based machine learning (ML) approaches using convolutional neural networks (CNNs) to "denoise" faster, lower-quality detector simulations, augmenting them to produce a higher-quality final result with a reduced computational burden. The denoising CNN works in concert with classical detector simulation software rather than replacing it entirely, increasing its reliability compared to other ML approaches to simulation. We obtain promising results from a prototype based on photon showers in the CMS electromagnetic calorimeter. Future directions are also discussed.

Banerjee, Sunanda↗

Denoising Convolutional Networks to Accelerate Detector Simulation [Poster]

The high accuracy of detector simulation is crucial for modern particle physics experiments. However, this accuracy comes with a high computational cost, which will be exacerbated by the large datasets and complex detector upgrades associated with next-generation facilities such as the High Luminosity LHC. We explore the viability of regression-based machine learning (ML) approaches using convolutional neural networks (CNN) to ``denoise'' faster, lower-quality detector simulations, augmenting them to produce a higher-quality final result with a reduced computational burden. The denoising CNN works in concert with classical detector simulation software rather than replacing it entirely, increasing its reliability compared to other ML approaches to simulation. We obtain promising results from a prototype based on photon showers in the CMS electromagnetic calorimeter. Future directions are also discussed.

43 PARTICLE ACCELERATORS↗

Validation of Physics Models of Geant4 Versions 10.4.p03, 10.6.p02 and 10.7.p01 using Data from the CMS Experiment

CMS tuned its simulation program and chose a specific physics model of Geant4 by comparing the simulation results with dedicated test beam experiments. Test beam data provide measurements of energy response of the calorimeter as well as resolution for well identified charged hadrons over a large energy region. CMS continues to validate the physics models using the test beam data as well as collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Different versions of Geant4 (10.2.p02, 10.4.p03, 10.6.p02) have been used by CMS for its Monte Carlo production and a new version (10.7.p01) is now chosen for future productions. A suitable physics list (collection of physics models) is chosen by optimizing performance against accuracy. A detailed comparison between data and Geant4 predictions is presented in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS Experience with Adoption of the Community supported DD4hep Toolkit

DD4hep is an open-source software toolkit that provides comprehensive and complete generic detector descriptions for high energy physics (HEP) detectors. The Compact Muon Solenoid collaboration (CMS) has recently evaluated and adopted DD4hep to replace its custom detector description software. CMS has demanding software requirements as a very large, longrunning experiment that must support legacy geometries and study many possible upgraded detector designs of a constantly evolving detector that will be taking data for many years to come. CMS has chosen DD4hep since it is a high-quality, community-supported solution that will benefit from continuing modernization and maintenance. This presentation will discuss the issues of DD4hep adoption, the advantages and disadvantages of the various design choices, performance results, and the integration of the plugin systems from CMS and Gaudi, another open-source software framework. Recommendations about DD4hep based upon the CMS use cases will also be presented.

Vuosalo, Carl↗

A Roadmap for HEP Software and Computing R&D for the 2020s

Particle physics has an ambitious and broad experimental programme for the coming decades. This programme requires large investments in detector hardware, either to build new facilities and experiments, or to upgrade existing ones. Similarly, it requires commensurate investment in the R&D of software to acquire, manage, process, and analyse the shear amounts of data to be recorded. In planning for the HL-LHC in particular, it is critical that all of the collaborating stakeholders agree on the software goals and priorities, and that the efforts complement each other. In this spirit, this white paper describes the R&D activities required to prepare for this software upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of Physics Models of Geant4 using Data from CMS Experiment

CMS has tuned its simulation program and has chosen a specific physics model of GEANT4 by comparing the simulation results with dedicated test beam experiments. CMS continues to validate the physics models inside GEANT4 using the test beam data as well as collision data. Several physics lists (collection of physics models) inside the most recent version of GEANT4 provide good agreement of the energy response, resolution of pions and protons. The validation results from these studies are used to make the choice of physics list and GEANT4 version for the CMS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation study of energy resolution, position resolution and $\pi^0$-$\gamma$ separation of a sampling electromagnetic calorimeter at high energies

A simulation study of energy resolution, position resolution, and π(0)-γ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the design geometry of the Shashlik calorimeter which was considered as a candidate for CMS endcap for the phase II of LHC running. The methods proposed in this paper can be easily adapted to various geometrical layouts of a sampling calorimeter. Energy resolution is studied for different layouts and different absorber-scintillator combinations of the Shashlik detector. It is shown that a boosted decision tree using fine grained information of the calorimeter can perform three times better than a cut-based method for separation of π(0) from γ over a large energy range of 20 GeV–200 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination of D0 measurements of the top quark mass

We present a combination of measurements of the top quark mass by the D0 experiment in the lepton+jets and dilepton channels. We use all the data collected in Run I (1992–1996) at s=1.8 TeV and Run II (2001–2011) at s=1.96 TeV of the Tevatron pp¯ collider, corresponding to integrated luminosities of 0.1 fb-1 and 9.7 fb-1, respectively. The combined result is: mt=174.95±0.40(stat)±0.64(syst) GeV=174.95±0.75 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the direct CP violating charge asymmetry in $B^\pm \rightarrow \mu^\pm \nu_\mu D^{0}$ decays

We present the first measurement of the CP violating charge asymmetry in B±→μ±νμD0 decays using the full Run II integrated luminosity of 10.4 fb-1 in proton-antiproton collisions collected with the D0 detector at the Fermilab Tevatron Collider. We measure a difference in the yield of B- and B+ mesons in these decays by fitting the reconstructed invariant mass distributions. This results in an asymmetry of AμD0=[-0.14±0.20]%, which is consistent with standard model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of top quark polarization in t t ¯ lepton + jets final states

We present a measurement of top quark polarization in t ¯ t pair production in p ¯ p collisions at √ s = 1.96 TeV using data corresponding to 9.7 fb -1 of integrated luminosity recorded with the D0 detector at the Fermilab Tevatron Collider. We consider final states containing a lepton and at least three jets. The polarization is measured through the distribution of lepton angles along three axes: the beam axis, the helicity axis, and the transverse axis normal to the t ¯ t production plane. This is the first measurement of top quark polarization at the Tevatron using lepton + jet final states and the first measurement of the transverse polarization in t ¯ t production. The observed distributions are consistent with standard model predictions of nearly no polarization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Inclusive $t\bar{t}$ Production Cross Section in $p\bar{p}$ Collisions at $\sqrt{s}=1.96$ TeV and Determination of the Top Quark Pole Mass

The inclusive cross section of top quark-antiquark pairs produced in pp¯ collisions at s=1.96 TeV is measured in the lepton+jets and dilepton decay channels. The data sample corresponds to 9.7 fb-1 of integrated luminosity recorded with the D0 detector during Run II of the Fermilab Tevatron Collider. Employing multivariate analysis techniques we measure the cross section in the two decay channels and we perform a combined cross section measurement. For a top quark mass of 172.5 GeV, we measure a combined inclusive top quark-antiquark pair production cross section of σtt¯=7.26±0.13(stat)-0.50+0.57(syst) pb which is consistent with standard model predictions. We also perform a likelihood fit to the measured and predicted top quark mass dependence of the inclusive cross section, which yields a measurement of the pole mass of the top quark. The extracted value is mt=172.8±1.1(theo)-3.1+3.3(exp) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of π 0 -γ separation study for proposed CMS forward electromagnetic calorimeter

The Forward Electromagnetic Calorimeter of the CMS detector is going to be upgraded in the high luminosity running as the energy of the present Electromagnetic Calorimeter (PbWO4) will degrade in the high luminosity (luminosity 10 34 cm -2 s -1 ) running due to extensive radiation (hadron flux 10 13 neutrons cm, -2 ). Shashlik Electromagnetic Calorimeter which consists of alternate layers of 1.5 mm LYSO(Ce) crystal plates and 2.5 mm Tungsten absorbers, was a proposal for high luminosity running. One of the performance points for any electromagnetic calorimeter is the ability to separate π 0 s from true photons, since final states with photons are a clean and one of the most important final states in proton-proton collisions at the LHC. As a result, the objective of this project is to study the possibility of π 0 and γ separation in the Shashlik detector using Multivariate Analysis (MVA) technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Top Quark Mass Using the Matrix Element Technique in Dilepton Final States

We present a measurement of the top quark mass in pp¯ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7 fb-1. The matrix element technique is applied to tt¯ events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton+jets final state of tt¯ decays is applied to jet energies. This correction provides a substantial reduction in systematic uncertainties. We obtain a top quark mass of mt=173.93±1.84 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

$B^{0}_{s}$ lifetime measurement in the CP-odd decay channel $B^{0}_{s} \to J/\psi f_{0}(980)$

The lifetime of the Bs0 meson is measured in the decay channel Bs0→J/ψπ+π- with 880≤Mπ+π-≤1080 MeV/c2, which is mainly a CP-odd state and dominated by the f0(980) resonance. In 10.4 fb-1 of data collected with the D0 detector in Run II of the Tevatron, the lifetime of the Bs0 meson is measured to be τ(Bs0)=1.70±0.14(stat)±0.05(syst) ps. Neglecting CP violation in Bs0/B¯s0 mixing, the measurement can be translated into the width of the heavy mass eigenstate of the Bs0, ΓH=0.59±0.05(stat)±0.02(syst) ps-1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗