Search NASA⌕ Search

Engineering topics

Barbera, M.

Publications and source records attributed to Barbera, M..

The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

SQUID amplifier↗

The LOFT Mission Concept - A Status Update

The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, is greater than 8m2 effective area, 2-30 keV, 240 eV spectral resolution, 1 degree collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g., GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the current technical and programmatic status of the mission.

Silicon detectors↗

X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

X-ray emission at the low-mass end - Results from an extensive Einstein Observatory survey

We have used available IPC data and a critical compilation of cataloged optical data to measure the 0.16-3.5 keV X-ray emission from 88 K and 169 M stars of luminosity classes IV, V, and VI within 25 pc from the Sun. The IPC detected 54 out of the 88 K stars, 70 out of the 138 M stars with M(v) less than 13.4, and 15 out of the 31 fainter M stars. We have identified a subsample of surveyed stars that is statistically representative of the population of K and M stars in the solar neighborhood. On the basis of this subsample (1) we have shown the occurrence of a drop in the level of X-ray emission for M stars later than approximately M5; (2) we have built unbiased maximum likelihood X-ray luminosity functions for the K, early M, and late M stars; (3) we have confirmed, both for K and M stars, the decrease of X-ray luminosity with increasing stellar age in the range of ages of disk population stars: and (4) we have shown that no obvious correlation is present between X-ray and bolometric luminosities in the entire representative samples of K and M stars, but only within flare stars which also seem to mark a saturation in X-ray luminosity level.

Barbera, M.↗

X-ray emission at low-mass end of the MS - Results from an extensive Einstein Observatory survey

The 0.16-4.0 keV X-ray emission from K and M stars of luminosity classes IV, V, and VI within 25 parsec of the sun was measured using all available Einstein Observatory IPC data and a critical compilation of catalogued optical data. Fifty four of 88 stars were detected, 70 of 138 M stars with Mv less than 13.4 (corresponding to M6) and 15 or 31 fainter M stars. The surveyed stars were grouped, on the basis of U, V, W space velocity components, into old-disk, young-disk, and halo population stars. Then, a subsample was selected which is statistically representative of the population of K and M stars in the solar neighborhood, on the basis of which unbiased Maximum Likelihood X-ray luminosity functions were constructed for K, early M, and late M stars. The investigation revealed a decrease of X-ray luminosity with increasing stellar age in the range of ages of disk population stars.

Barbera, M.↗