Search NASA⌕ Search

Engineering topics

Barbos, D

Publications and source records attributed to Barbos, D.

The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: {phi}{sub scd} = 1.10{sup 6} n/cm{sup 2}/s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗