Combined distance-of-flight and time-of-flight mass spectrometer

A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

47 OTHER INSTRUMENTATION↗

Extension of the Focusable Mass Range in Distance-of-Flight Mass Spectrometry with Multiple Detectors

Since the underlying theory of Distance-of-Flight Mass Spectrometry (DOFMS) was reported in 2007,[1] laboratory results[2, 3] have proven its practical viability. However, these previous implementations of DOFMS considered ion detection only over narrow DOF-detection windows, with 25-mm being the greatest detection length explored. These small mass windows cannot be used to evaluate how DOFMS focusing performs over greater DOF detection lengths and mass ranges. In the present study, we expand on previous studies by placing two spatially selective ion detectors along the detection plane of the DOFMS instrument. Ion signals are simultaneously collected from both DOF detectors in order to simulate DOFMS performance with a longer spatially selective ion detector.

Gundlach-Graham, Alexander W↗

Distance-of-Flight Mass Spectrometry: A New Paradigm for Mass Separation and Detection

Distance-of-flight mass spectrometry (DOFMS) offers the advantages of physical separation of ions, array-detection of ions, focusing of initial ion energy, great simplicity, and truly unlimited mass range. DOFMS instrumentation is similar to that of time-of-flight mass spectrometry (TOFMS) and shares its ion source versatility, batch analysis, and rapid spectral generation rate. With constant-momentum ion acceleration and an ion mirror, there is a time at which ions of all m/z values are energy-focused at their particular distance along the flight path. A pulsed field orthogonal to the flight path drives the ions to reach the detector array at this specific time. Results from a 0.31-m proof-of-principle instrument verify the theoretically predicted energy focus and demonstrate how the range of m/z values impinging on the detector array can be readily changed. DOFMS can potentially be combined sequentially with TOFMS to enable simultaneous scanless MS/MS.

dynamic range↗

Reduction of polyatomic interferences in ICP-MS by collision/reaction cell (CRC-ICP-MS) techniques

Polyatomic and other spectral interferences in plasma source mass spectrometry (PSMS) can be dramatically reduced using collision and reaction cells (CRC). These devices have been used for decades in fundamental studies of ion-molecule chemistry, but have only recently been applied to PSMS. Benefits of this approach as applied in inductively coupled plasma MS (ICP-MS) include interference reduction, isobar separation, and thermalization/focusing of ions. Novel ion-molecule chemistry schemes are now routinely designed and empirically evaluated with relative ease. These “chemical resolution” techniques can avert interferences requiring mass spectral resolutions of >600,000 (m/m). Purely physical ion beam processes, including collisional dampening and collisional dissociation, are also employed to provide improved sensitivity, resolution, and spectral simplicity. CRC techniques are now firmly entrenched in current-day ICP-MS technology, enabling unprecedented flexibility and freedom from many spectral interferences. A significant body of applications has now been reported in the literature. CRC techniques are found to be most useful for specialized or difficult analytical needs and situations, and are employed in both single- and multi-element determination modes.

collision cell↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry

A new, low power ionization source for elemental MS analysis of aqueous solutions is described. The liquid sampling-atmospheric pressure glow discharge (LSAPGD) operates by a process wherein the surface of the liquid emanating from a 75 μm i.d. glass capillary acts as the cathode of the direct current glow discharge. Analytecontaining solutions at a flow rate of 100 μL min-1 are vaporized by the passage of current, yielding gas phase solutes that are subsequently ionized in the < 5 W (maximum of 60 mA and 500 V), ~1 mm3 volume, plasma. The LS-APGD is mounted in place of the normal electrospray ionization source of a Thermo Scientific Exactive orbitrap mass spectrometer system. Basic operating characteristics are described, including the role of discharge power on mass spectral composition, the ability to obtain ultra-high resolution elemental isotopic patterns, and preliminary limits of detection attainable based on the injection of aliquots of multielement standards. While much optimization remains, it is believed that the LS-APGD may present a practical alternative to high-powered (>1 kW) plasma sources typically employed in elemental mass spectrometry, particularly for those cases where costs, operational overhead, and simplicity considerations are important.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Distance-of-Flight Instrument: Opening A New Paradigm in Mass Spectrometry

Operation of the first distance-of-flight mass spectrometry (DOFMS) instrument is demonstrated. DOFMS measures the mass-to-charge ratio of ions based upon the distance each ion travels during a fixed time period, and records a mass spectrum with a position-sensitive detector. Initial results are demonstrated with a glow discharge source for atomic ion determination.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L-1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a third-generation Faraday-strip array detector coupled to a Mattauch-Herzog geometry mass spectrograph with a dc-glow discharge ionization source

A third-generation Faraday-strip array detector has been coupled to a Mattauch-Herzog mass spectrometer and dc glow-discharge ionization source. This combination offers simultaneous determination of multiple elements directly from solid samples and provides superior resolving power and improved limits of detection over previous generations of array detectors. With the thirdgeneration detector array, resolving power is limited only by the mass spectrometer and not by the array. Because of this enhanced resolution, limits of detection, especially for higher mass-to-charge ratios, were improved. Isotope-ratio precision was found to be 0.07% RSD on average and quantitative response was linear over 5 orders of magnitude.

47 OTHER INSTRUMENTATION↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of an ambient ionization flowing atmospheric-pressure afterglow source for elemental analysis through hydride generation

An ambient mass spectrometry ionization source based on an atmospheric-pressure flowing afterglow has been coupled to a Mattauch-Herzog mass spectrograph capable of simultaneous acquisition of a range of mass-to-charge values by means of a Faraday-strip array detector. The flowing afterglow was used as the ionization pathway for species produced by hydride generation. This ionization strategy circumvents problems, such as discharge instabilities or memory effects, induced by introducing the gaseous sample into the discharge. The generated spectra show both atomic and molecular peaks; calibration curves were calculated for both peak types with limits of detection for arsenic below 10 ppb. This study demonstrates the ability to use an ambient mass spectrometry source, commonly used for molecular analyses, for the detection of gas phase elemental species with the possibilty of performing speciation by coupling with a separation technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Simultaneous Detection in Mass Spectrometry

In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗