Search NASA⌕ Search

Engineering topics

Barry, Devin

Publications and source records attributed to Barry, Devin.

Resolved Resonance Evaluation for Neutron Interactions with 103 Rh up to 8 keV

A neutron cross-section evaluation for the n + 103 Rh reaction in the resolved resonance region was carried out in the energy range 10−5 eV to 8 keV encompassing thermal energy at 0.0253 eV. The scope of this work is to generate resonance parameters and resonance parameter covariances based on the Reich-Moore reduced R-matrix formalism using the code SAMMY. Some features of the new evaluation are the inclusion of high-resolution capture data in the SAMMY evaluation process and the extension of the resolved resonance range from 4 to 8 keV. Furthermore, the evaluation employs more accurate resonance parameter representation by exploring the use of the LRF = 7 ENDF feature and also the use of the LCOMP = 2 compact format for resonance parameter covariance representation. Included in the SAMMY evaluation are transmission data, capture cross-section data, and neutron scattering length information. Thermal cross-section values listed in the literature, as well as capture resonance integrals, were also incorporated into the evaluation process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

SG50 Data-format Requirement Document for an Automatically Readable, Comprehensive and Curated Experimental Reaction Database MEDUSA

This report constitutes the requirement document that guides the development of the experimental reaction database, MEDUSAL (Machine-readable Experimental Data User App & Library), created by OECD/NEA/WPEC SubGroup 50. Experimental reaction data are usually stored in the EXFOR library in EXFOR format. With MEDUSAL, the WPEC sub-group 50 wants to go beyond the EXFOR format and database to generate a library that is (a) automatically readable, (b) comprehensive, and (c) curated.

Nuclear Criticality Safety Program (NCSP)↗

Improvements of Nuclear Data Evaluations for Lead Isotopes in Support of Next Generation Lead-Cooled Fast Systems

The neutron evaluation of the isotopes that comprise natural lead were undertaken as a part of DOE-NEUP Project #19-16739. The goal of the project was to update the neutron cross sections to account for new differential measurements and incorporate the most up-to-date physics. Shortcomings in the lead cross sections was made known by several independent reports. The work performed here repeated the simulation of all the “benchmark” validation systems and concluded that the major issue is the scattering cross sections in the major lead isotopes above 100 keV. Re-evaluation of 206,207,208 Pb included both the resolved resonance region and fast region evaluations of the cross sections. Combined these regions cover energies from thermal to 20 MeV. The most drastic improvement is the resolved resonance region evaluation of 208 Pb which is now extended from 1.0 to 1.5 MeV. Parameterization of these resonances in the R-matrix provides a superior reconstruction of not only the experimental cross section but also the scattering distributions via the Blatt-Biedenharn formalism. Fast region evaluations of the three major isotopes were done to include new inelastic experimental data from the neutron Time-of-Flight facility at CERN. The culmination of all the changes to the cross section is a drastic improvement in the scattering kernel as shown in Rensselaer Polytechnic Institute (RPI) Quasi-Differential scattering measurements and improved prediction of keff for fast integral experiments. Alongside the new cross sections, new nuclear data covariance (uncertainties) have been computed and are included in the evaluation. Little is changed in the magnitude of the uncertainties but the correlations within the covariance display non-trivial changes. The new evaluations of 206,207,208 Pb have been submitted to the National Nuclear Data Center to be included in the ENDF/B-VIII.1 library. While the cross sections have been updated extensively, knowledge and modeling of the cross sections between 1.0 and 3.0 MeV for the isotopes remain a challenge. Most notably is the double differential elastic cross section for 208 Pb and 206 Pb. New quasi-differential measurements for pure samples of these two nuclei would go a long way in reducing compensating errors in the evaluations. Qualitatively, the project has produced a prosperous collaboration between the nuclear data group at RPI with staff scientists at Brookhaven National Laboratory, Naval Nuclear Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratories. Quantitatively this is reflected in seven conference presentations, at least one journal submission, and one doctoral thesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parameterization of Direct and Doorway Processes in R-Matrix Formalism

R-matrix formalism is extended beyond compound nuclear (CN) resonant reactions to include parameterization of direct as well as doorway processes. Direct processes in the R-matrix exterior are parameterized by a unitary matrix that introduces mixing among wave function coefficients of the incoming and outgoing wave function components at the R-matrix channel surface. Doorway processes are parameterized by separating the Hilbert space of the interior R-matrix region into its doorway and CN subspaces, from which doorway state eigenenergies, reduced width amplitudes, and the strengths of their coupling to CN levels appear as new R-matrix parameters. Parameterization of generalized as well as the conventional Reich–Moore approximation for eliminated capture channels in the presence of direct, doorway, and CN processes is presented along with a complex-valued scattering length with contributions from direct, doorway, and CN capture processes. Derivation of Brune’s alternative R-matrix parameters is extended to include doorway states. This work suggests how R-matrix formalism could be extended further by adopting the concepts from related reaction formalisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolved Resonance Region Analysis of 206 Pb, 207 Pb, and 208 Pb for Next Generation Lead-Cooled Fast Systems

Recently, great interest has been generated in using lead as a coolant for fast neutron systems and as a result it is important to investigate the ENDF/B-VIII.0 isotopic evaluations that comprise stable le ad. To this end, resonance parameters for 206 Pb, 207 Pb, and 208 Pb were re-evaluated because their resolved reso­nance regions extend beyond 0.5 MeV meaning resonance parameters used in reconstructing cross sections and elastic scattering angular distributions impact fast systems. The impact of resonance parameters is demon­strated by the differences between the evaluations in predicting experimental results from the fully modeled RPI Quasi-Differential Scattering Experiment via MCNPv6.2. In addition, MCNP KCODE calculations of lead-sensitive fast spectra critical benchmarks showed variations of keff on average of 400 pcm, caused solely from differences in elastic scattering angular distributions in 208 Pb. Re-evaluation entailed fitting data with the program SAMMY.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Validation of Thermal Scattering Evaluations

In order to test the performance of new neutron thermal scattering law (TSL) evaluations it is desirable to have experimental data that is highly sensitive to the TSL and provides high fidelity information on the energy dependent performance of TSL evaluations. Three relevant experiments are discussed including: accurate thermal total cross section measurements, thermal neutron die-away experiments, and neutron leakage experiments. The experimental setups and results are reviewed, and examples provided for some moderators including polyethylene, Plexiglas, and YHx. For the experiments preformed thus far, there is generally good agreement between the measured total cross section and simulations using current TSL evaluations, however in certain energy ranges differences were observed. Similarly, neutron die-away and leakage measurements for samples at room temperature are in good agreement with data computed from TSLs, however leakage measurements for polyethylene at 29K show discrepancies with TSL evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WPEC SG50: Developing an Automatically Readable, Comprehensive and Curated Experimental Nuclear Reaction Database

The Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Co-operation (WPEC) subgroup (SG) 50 was formed in 2020 to develop an automatically readable, comprehensive and curated experimental nuclear reaction database. This database is called MEDUSAL (Machine-readable Experimental Data User Application & Library), and will draw from EXFOR. The EXFOR database preserves experimental nuclear reaction data true to its original documentation and information from the authors of the data. MEDUSAL will deviate from EXFOR by storing additional information from users of the data for their fields of work (evaluation, model development, validation, etc.). This includes expert judgment on the data sets, identification of data points as outliers, renormalization of the data to the newest monitor reactions, and estimations of missing uncertainty sources. The format for MEDUSAL is being developed to enable easy automatic parsing of large amounts of data. Here, we will summarize the use cases, high-level requirements and first steps towards developing the database MEDUSAL and the API to access it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments for validation of TSL evaluations [Slides]

There is a recent revival of thermal scattering evaluation capabilities and there are many new evaluations available in ENDF-8.0 and elsewhere. This creates a need for experimental validation other than criticality benchmarks. Thermal scattering libraries (TSL) provide information to describe the double differential thermal scattering at different moderator temperatures. For moderators, the biggest effect of TSL is the thermal scattering cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress on the R-matrix Analysis for the n+ 181 Ta Evaluation [Slides]

This presentation discusses how nuclear data evaluations can influence the accuracy of computational nuclear design calculations. It also discusses the motivation for a new evaluation of 181 Ta. The goals of the evaluations are to generate a set of resonance parameters in the Resolved Resonance Region (RRR) that extends up to 2.6 keV, to generate a set of average resonance parameters in the Unresolved Resonance Region (URR) up to 100 keV (derived from the RRR parameters), and to generate covariance information for both RRR and URR. The presentation discusses how several different experimental data sets will be fit simultaneously in the evaluation of 181 Ta. It states that the level density of 181 Ta can make R-matrix fitting a challenge as the width of the levels increase with energy (as well as decreasing experimental resolution) and the measured resonances can overlap. The presentation concludes by discussing R-matrix analysis and covariance information as the latter is important when propagated to quantify the uncertainty on output responses of nuclear design calculations such as the multiplication factor k .

07 ISOTOPE AND RADIATION SOURCES↗