Search NASA⌕ Search

Engineering topics

Barton, Dallin J.

Publications and source records attributed to Barton, Dallin J..

Micro-Quantification of Helium-3 and Helium-4 in TPBAR Components

This report documents the method development for measuring helium isotopes in micrometer-sized samples of tritium producing burnable absorption rod (TPBAR) components. Helium isotopes were measured as a tracer for tritium, which decays to 3 He with a half-life of 12.33 years. Getter and cladding materials from the TPBARs were analyzed, as they are designed to trap tritium. Therefore, constraining the diffusivity of tritium through these materials is of key importance. To first establish the reliability of the noble gas mass spectrometer, a reference gas with a relative 4 He/ 3 He ratio of 1000 was pre-mixed. This standard was measured several times to ensure measurements were reproducible. Unirradiated and irradiated getter and cladding samples of TPBARs were cut into 1-100 µm 3 cubes and analyzed for 3 He and 4 He content. The unirradiated materials had helium content equal to or less than that of the measured instrument background. Irradiated cladding also had instrument background levels of helium while irradiated getters had elevated levels of 3 He, interpreted to be the decay product of tritium. No diffusion of 4 He was observed in any of these materials, however, indicating that the 3 He detected in the irradiated getter was produced in situ after tritium diffusion and decay. These findings validate this method as a way to trace tritium diffusion in reactor materials.

07 ISOTOPE AND RADIATION SOURCES↗

Nanoscale Mapping of Hydrogen Distribution in Nuclear Structural Materials Using Cryogenic Transfer Atom Probe Tomography

Analyzing hydrogen distribution in nuclear structural materials at sub-nanometer scale spatial resolution has been challenging by electron microscopy. Furthermore, methods such as thermal desorption spectroscopy only provides a bulk estimate of hydrogen concentration with no nanoscale spatial resolution. In the last decade, cryogenic transfer atom probe tomography (APT) has been emerging as an invaluable characterization technique for analyzing the nanoscale distribution of hydrogen isotopes in materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rationally Engineered Vertically Aligned β ‐Ga 2− x W x O 3 Nanocomposites for Self‐Biased Solar‐Blind Ultraviolet Photodetectors with Ultrafast Response

Abstract With the astonishing advancement of present technology and increasing energy consumption, there is an ever‐increasing demand for energy‐efficient multifunctional sensors or transducers based on low‐cost, eco‐friendly material systems. In this context, self‐assembled vertically aligned β ‐Ga 2− x W x O 3 nanocomposite (GWO‐VAN) architecture‐assisted self‐biased solar‐blind UV photodetection on a silicon platform, which is the heart of traditional electronics is presented. Utilizing precisely controlled growth parameters, the formation of W‐enriched vertical β ‐Ga 2− x W x O 3 nanocolumns embedded into the W‐deficient β ‐Ga 2− x W x O 3 matrix is reached. Detailed structural and morphological analyses evidently confirm the presence of β ‐Ga 2− x W x O 3 nanocomposite with a high structural and chemical quality. Furthermore, absorption and photoluminescence spectroscopy explains photo‐absorption dynamics and the recombination through possible donor–acceptor energy states. The proposed GWO‐VAN framework facilitates evenly dispersed nanoregions with asymmetric donor energy state distribution and thus forms build‐in potential at the vertical β ‐Ga 2− x W x O 3 interfaces. As a result, the overall heterostructure evinces photovoltaic nature under the UV irradiation. A responsivity of ≈30 A/W is observed with an ultrafast response time (≈350 µs) under transient triggering conditions. Corresponding detectivity and external quantum efficiency are 7.9 × 10 12 Jones and 1.4 × 10 4 %, respectively. It is believed that, while this is the first report exploiting GWO‐VAN architecture to manifest self‐biased solar‐blind UV photodetection, the implication of the approach is enormous in designing electronics for extreme environment functionality and has immense potential to demonstrate drastic improvement in low‐cost UV photodetector technology.

Das, Debabrata↗

Visualizing the Nanoscale Oxygen and Cation Transport Mechanisms during the Early Stages of Oxidation of Fe–Cr–Ni Alloy Using In Situ Atom Probe Tomography

Abstract Understanding the early stages of interactions between oxygen and material surfaces—especially at very high spatial resolutions—is highly beneficial for fields ranging from materials degradation, corrosion, geological sciences, forensics, and catalysis. The ability of in situ atom probe tomography (APT) is demonstrated to track the diffusion of oxygen and metal ions at nanoscale spatial resolution during the early stages of oxidation of a model Fe–Cr–Ni alloy. Using 18 O isotope tracers in these in situ APT experiments and complementary ex situ multimodal microscopy, spectroscopy, and computational simulations allows to precisely analyze the kinetics of oxidation and determine that outward cation diffusion to oxide/air interface is the primary mechanism for intragranular oxide growth in this alloy at 300 °C. This unique in situ isotopic tracer APT approach and the insights gained can be highly beneficial for studying early stages of gas–surface reactions in a broad array of materials.

36 MATERIALS SCIENCE↗