Search for the Rare Decays B s 0 → e + e − and B 0 → e + e −
Not Available
Engineering topics
Publications and source records attributed to Bassi, G..
Not Available
The ratio of branching fractions of the decays \( {\Lambda}_b^0 \) → pK - e + e - and \( {\Lambda}_b^0 \) → pK - μ + μ - , \( {R}_{pK}^{-1} \) , is measured for the first time using proton-proton collision data corresponding to an integrated luminosity of 4 . 7 fb - 1 recorded with the LHCb experiment at center-of-mass energies of 7, 8 and 13 TeV. In the dilepton mass-squared range 0 . 1 < q 2 < 6 . 0 GeV 2 /c 4 and the pK - mass range m ( pK - ) < 2600 MeV /c 2 , the ratio of branching fractions is measured to be \( {R}_{pK}^{-1}={1.17}_{-0.16}^{+0.18}\pm 0.07 \) , where the first uncertainty is statistical and the second systematic. This is the first test of lepton universality with b baryons and the first observation of the decay \( {\Lambda}_b^0 \) → pK - e + e - .
Not Available
In this work the heat transfer analysis has been performed for the stripline kicker, design of which is used at many accelerator facilities as a part of the transverse bunch-by-bunch feed-back system, including NSLS-II. The experimental data of the electrode temperature have been collected from a special diagnostic stripline designed with six infrared view ports. The temperature analysis is based on the power loss calculations and the loss factor computed by the 3-D electromagnetic simulation code GdfidL. To estimate the power loss, we analyze the real part of the longitudinal impedance and the loss factor for two different regimes. We use the ANSYS finite element code to correlate the temperature with the power loss. Lambertson and Shafer formalisms of the longitudinal and transverse beam impedances are discussed for the simplified stripline geometries. The required characteristic impedances and the geometric factors are determined analytically for the simplified geometries and compared with the results for the designed stripline geometry using the 2-D POISSON code by solving the Laplace’s equation in two dimensions. Lambertson’s equations are compared with numerical results. We introduce the frequency range, within which we can apply the analytical approach.
A search for the doubly charmed baryon $\Xi_{cc}^+$ is performed through its decay to the $Λ$ $^{+}_{c}$ K – π + final state, using proton-proton collision data collected with the LHCb detector at centre-of-mass energies of 7, 8 and 13 TeV. The data correspond to a total integrated luminosity of 9 fb –1 . No significant signal is observed in the mass range from 3.4 to 3.8 GeV/c 2 . Upper limits are set at 95% credibility level on the ratio of the $\Xi_{cc}^+$ production cross-section times the branching fraction to that of $Λ$ $^{+}_{c}$ and $\Xi_{cc}^{++}$ baryons. The limits are determined as functions of the $\Xi_{cc}^+$ mass for different lifetime hypotheses, in the rapidity range from 2.0 to 4.5 and the transverse momentum range from 4 to 15 GeV/c.
Explore the source record for details and available documents.
We report on beam studies performed at NSLS-II to test the performance of the APS-U Bellows/BPM assembly.
Here, novel features of the longitudinal instability of a single electron bunch circulating in a low-emittance electron storage ring are discussed. Measurements and numerical simulations, performed both in time and frequency domain, show a non-monotonic increase of the electron beam energy spread as a function of single bunch current, characterized by the presence of local minima and maxima, where a local minimum of the energy spread is interpreted as a higher-order microwave instability threshold. It is also shown that thresholds related to the same zero-intensity bunch length depend linearly on the accelerating radio frequency voltage. The observed intensity-dependent features of the energy spread, confirmed by measurements with two independent diagnostics methods, i.e. horizontal beam profile measurements by a synchrotron light monitor and photon energy spectrum measurements of undulator radiation, are given a theoretical interpretation by applying a novel eigenvalue analysis based on the linearized Vlasov equation.
Explore the source record for details and available documents.
The National Synchrotron Light Source II at Brookhaven National Lab is a third-generation synchrotron radiation facility that has been commissioned in 2014. The facility is based on a 3 GeV electron storage ring, which will circulate 500 mA of beam current at 1 nm rad horizontal emittance. The storage ring is 792 meters in circumference and will accommodate more than 60 beamlines in the final built-out. The beamline sources range from insertion-devices located in straight sections, bending magnets or three-pole-wigglers configured in multiple branches. The NSLS-II storage ring commissioning was successfully completed in July 2014 and the facility delivered the first user light on October 23, 2014. Currently the storage ring reached 300 mA beam current and achieved 1 nm rad of horizontal emittance with 3 sets of Damping Wigglers. At this point six NSLS-II project beamlines are routinely taking photons with beam current at 150 mA. This paper reviews the NSLS-II accelerator design and commissioning experience.
The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed. We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.