Search NASA⌕ Search

Engineering topics

Bates, J.

Publications and source records attributed to Bates, J..

Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: 7 HIRS (High-resolution Infrared Sounder) and 4 AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging, In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models, Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

Garand, L.↗

Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: seven HIRS (High-resolution Infrared Sounder) and four AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor, and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging. In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models. Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

Garand, L.↗

An Intercomparison of Radiation Codes for Retrieving Upper Tropospheric Humidity in the 6.3-micron Band: A Report from the 1st GVaP Workshop

An intercomparison of radiation codes used in retrieving upper tropospheric humidity (UTH) from observations in the v2 (6.3 microns) water vapor absorption band was performed. This intercomparison is one part of a coordinated effort within the GEWEX Water Vapor Project (GVaP) to assess our ability to monitor the distribution and variations of upper tropospheric moisture from space-borne sensors. A total of 23 different codes, ranging from detailed line-by-line (LBL) models, to coarser resolution narrow-band (NB) models, to highly-parameterized single-band (SB) models participated in the study. Forward calculations were performed using a carefully selected set of temperature and moisture profiles chosen to be representative of a wide range of atmospheric conditions. The LBL model calculations exhibited the greatest consistency with each other, typically agreeing to within 0.5 K in terms of the equivalent blackbody brightness temperature (T(sub b)). The majority of NB and SB models agreed to within +/- 1 K of the LBL models, although a few older models exhibited systematic T(sub b) biases in excess of 2 K. A discussion of the discrepancies between various models, their association with differences in model physics (e.g. continuum absorption), and their implications for UTH retrieval and radiance assimilation is presented.

Soden, B.↗

Comparisons of Upper Tropospheric Humidity Retrievals from TOVS and METEOSAT

Two different methods for retrieving Upper Tropospheric Humidities (UTH) from the TOVS (TIROS Operational Vertical Sounder) instruments aboard NOAA polar orbiting satellites are presented and compared. The first one, from the Environmental Technology Laboratory, computed by J. Bates and D. Jackson (hereafter BJ method), estimates UTH from a simplified radiative transfer analysis of the upper tropospheric infrared water vapor channel at wavelength measured by HIRS (6.3 micrometer). The second one results from a neural network analysis of the TOVS (HIRS and MSU) data developed at, the Laboratoire de Meteorologie Dynamique (hereafter the 3I (Improved Initialization Inversion) method). Although the two methods give very similar retrievals in temperate regions (30-60 N and S), an absolute bias up to 16% appears in the convective zone of the tropics. The two datasets have also been compared with UTH retrievals from infrared radiance measurements in the 6.3 micrometer channel from the geostationary satellite METEOSAT (hereafter MET method). The METEOSAT retrievals are systematically drier than the TOVS-based results by an absolute bias between 5 and 25%. Despite the biases, the spatial and temporal correlations are very good. The purpose of this study is to explain the deviations observed between the three datasets. The sensitivity of UTH to air temperature and humidity profiles is analysed as are the clouds effects. Overall, the comparison of the three retrievals gives an assessment of the current uncertainties in water vapor amounts in the upper troposphere as determined from NOAA and METEOSAT satellites.

Escoffier, C.↗

A satellite data processing and analysis software system for earth's atmosphere and surface research

The OASIS (Oceanic and Atmospheric Satellite Imaging System) is a satellite data processing and analysis software system being developed by the California Space Institute (Cal Space) for support of interdisciplinary and integrated earth sciences research programs. The system's software applications are integrated under a common executive, NASA's Transportable Application Executive (TAE). In this paper, TAE and the system software and hardware are described, and specific techniques used for ingesting, processing, analyzing, and graphically displaying data from many of the sensors presently being flown are presented. Scientific uses of these capabilities that are, or will shortly be, running under TAE at Cal Space are described.

Dealy, B.↗

Use of VAS multispectral data for sea surface temperature determination

The Visible Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) is a radiometer possessing eight visible channel detectors and six thermal detectors that sense infrared radiation in 12 spectral bands. Housed in the GOES satellite, VAS spins in a west to east direction at 100 rpm and achieves spatial coverage at resolutions of 1 km in the visible and 7 or 14 km in the infrared by stepping a scan mirror in a north to south direction. Designed for multipurpose applications, the VAS can be operated in two different modes: (1) a multi-spectral imaging (MSI) mode, and (2) a dwell sounding (DS) mode. The MSI mode of operation is used for sea surface temperature (SST) determination. Currently, a full-disk MSI image for SST determination is received every hour, 18 hours a day during weekdays. This MSI mode of operation for SST consists of data obtained from wavelengths centered at 3.9 microns (channel 12), 11.6 microns (channel 8), and 12.6 microns (channel 7) as well as visible data.

Bates, J.↗