Search NASA⌕ Search

Engineering topics

Batir, Joseph

Publications and source records attributed to Batir, Joseph.

INGENIOUS - Great Basin Regional Dataset Compilation

This is the regional dataset compilation for the INnovative Geothermal Exploration through Novel Investigations Of Undiscovered Systems (INGENIOUS) project. The primary goal of this project is to accelerate discoveries of new, commercially viable hidden geothermal systems while reducing the exploration and development risks for all geothermal resources. These datasets will be used in INGENIOUS as input features for predicting geothermal favorability throughout the Great Basin study area. Datasets consist of shapefiles, geotiffs, tabular spreadsheets, and metadata that describe: 2-meter temperature probe surveys, quaternary faults and volcanic features, geodetic shear and dilation models, heat flow, magnetotellurics (conductance), magnetics, gravity, paleogeothermal features (such as sinter and tufa deposits), seismicity, spring and well temperatures, spring and well aqueous geochemistry analyses, thermal conductivity, and fault slip and dilation tendency. For additional project information, see the INGENIOUS project site linked in the submission. Terms of use: These datasets are provided "as is", and the contributors assume no responsibility for any errors or omissions. The user assumes the entire risk associated with their use of these data and bears all responsibility in determining whether these data are fit for their intended use. These datasets may be redistributed with attribution (see citation information below). Please refer to the license information on this page for full licensing terms and conditions.

15 GEOTHERMAL ENERGY↗

INGENIOUS Thermal Conductivity Measurement Source Categorization

Thermal conductivity (TC) data taken for different wells at a specified drill depth. This is an abridged version of the complete SMU heat flow database, downloaded from the SMU node of the NGDS at the beginning of INGENIOUS (approximately April 2021), and filtered to the INGENIOUS study area. This National Geothermal Data System (NGDS) project aggregates geothermal data collected and curated by the SMU Geothermal Laboratory and its partner organizations. All columns in this database are the same as the SMU database, except for 2 additions associated with this project. Repeated columns are for data correlation purposes. Column descriptions and data types are the same as previous iterations of the SMU database. The new values that are the addition are two new columns developed as part of the INGENIOUS project: INGENIOUS TC Value | INGENIOUS notes INGENIOUS notes are individual notes that were written for specific data points during the analysis process. There are not always notes associated with each input value. INGENIOUS TC Value includes 4 values: 1. Assumed Measured These are values that are assumed to be measured thermal conductivity values, either within a specific well or within the same study region. Many of these have either a published reference, a reported standard deviation, or a unique thermal conductivity value. 2. Data release - assumed measured These are values in the SMU database that are from proprietary data that were added to the SMU database and are labeled as data release for their reference. These values were searched for in person at the SMU Geothermal Laboratory as well as virtual examination of data available on the NGDS. For many of these, there are reported thermal conductivity values associated with the heat flow data in the database, but no specific table or reference to measurements in the original data release files. 3. Known measured These are values that have a reported measurement, either as an original file in the SMU data files on the NGDS or a reported table in a publication. In the rare circumstances, Maria Richards or David Blackwell confirmed measurement. Confirmation of measurement would be written in the INGENIOUS notes column. 4. Unmeasured Unmeasured values are those that are known to be unmeasured, either estimated from another report or no information given. In the SMU database, there are wells that have a heat flow but no thermal conductivity. These are categorized as unmeasured. There are also heat flow values that are stated to have estimated or generalized average thermal conductivity values for the region and rock type. Because these are known to be unmeasured, they are categorized as such. 5. Blank Blank values are either A quality or X quality. These quality values are stated in the INGENIOUS notes. These values were not going to change associated with the heat flow analysis, so these were not examined.

15 GEOTHERMAL ENERGY↗

Shallow EGS Regional Resource Potential and Map - Snake River Plain

SMU Geothermal Lab developed a methodology to estimate shallow (1 km to 4 km) Enhanced Geothermal Systems (EGS) resource potential using an approach that utilizes recent geology and geophysical research along with new well data to improve the thermal conductivity model, mitigate impacts from groundwater flow in the thermal model, and examine radioactivity data variations. By incorporating the results of the most recent projects with the SMU shallow methodology, we developed a more accurate, updated resource estimate for the Snake River Plain (SRP). The resulting maps and resource estimates can be used by the National Renewable Energy Lab (NREL), Bureau of Land Management (BLM), and the public to determine how best to move forward with future project development.

15 GEOTHERMAL ENERGY↗

Shallow Geothermal Potential of the Snake River Plain

The Snake River Plain (SRP) terrestrial heat flow and subsurface thermal regime are not well understood but are important for assessing the local geothermal resource potential, both for conventional and for Enhanced Geothermal Systems (EGS) development in the region. Resource evaluation for the SRP is complicated by the disparate data density, along with the known lateral advection of heat in the Eastern Snake River Plain Aquifer and vertical heat transport by fluids in the bounding faults, primarily in the southwestern section. Fortunately, recent studies, e.g., the Snake River Plain Play Fairway Analysis, the Idaho FORGE site, and site-specific investigations, which included drilling within the Camas Prairie and on the Mountain Home Air Force Base, near Twin Falls, and in the Eastern Snake River Plain as part of the HOTSPOT Project, add both additional drilling and geophysical data. The SMU Geothermal Laboratory has conducted detailed studies of SRP tectonics and heat flow since the 1970's and used this knowledge as part of the EGS geothermal potential estimation for the conterminous United States in 2006 and again in 2011, calculating geothermal potential from 3.5 km to 10 km depth. Recent temperature modeling refined the calculation methodology to estimate shallow (1 km to 4 km) resource potential using an improved thermal conductivity model and incorporation of shallow groundwater flow. By incorporating the new SRP geology, geophysics, and 206 thermal data sites into the SMU thermal modeling methodology, this project updates the resource estimate for the SRP, and generates new temperature-at-depth maps for the shallow subsurface (1 km to 4 km). The project results highlight the EGS potential resource areas (=150°C) and areas with more exploration risks based on minimal and/or low-quality data. The newest temperature modeling results suggest EGS potential is near five times greater in the SRP than previously estimated.

EGS↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Resource Analysis for Deep Direct-Use Feasibility Study in East Texas, Part 2

The National Renewable Energy Laboratory, Southern Methodist University Geothermal Laboratory, Eastman Chemical, Turbine Air Systems, and the Electric Power Research Institute are evaluating the feasibility of using geothermal heat to improve the efficiency of natural gas power plants. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of the Sabine Uplift. Part 2 focus on: 1) Permit report and spreadsheet on Federal, State, and Local agency requirements for a geothermal deep direct-use project in the vicinity of East Texas for Harrison, Gregg, Rusk, and Panola Counties. 2) Evaluation of the Geologic Variability of Travis Peak Formation as a reservoir. 3) Updated Heat Flow Memo with additional references.

15 GEOTHERMAL ENERGY↗

Resource Analysis for Deep Direct-Use Feasibility Study in East Texas

The National Renewable Energy Laboratory, Southern Methodist University Geothermal Laboratory, Eastman Chemical, Turbine Air Systems, and the Electric Power Research Institute are evaluating the feasibility of using geothermal heat to improve the efficiency of natural gas power plants. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of the Sabine Uplift. The study is focused on determining the potential for a geothermal reservoir within a 10 km radius of the site as defined by data from existing geological studies and cross-sections within the depths of 2,100 to 3,400 meters. Wells within a 20 km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, and oil and gas field porosity and permeability. The geothermal reservoir model is based on the multiple formation top data sources, published literature data, and well log interpretations within the 10 km radius. Area thickness estimates, reservoir extent bounding parameters, potential flow rates, and temperatures are combined to calculate a reservoir productivity index and develop a reservoir production model. Historical fluid volumes production data are used as an independent check for the reservoir productivity index and production model results. The reservoir parameters calculated here are being used for the surface engineering model to determine the economic viability of using geothermal fluids for a deep direct use application at this site. The data files are submitted as separate workbooks in 'content model' format, including: Well Fluid Production, Heat Flow, and Geologic Reservoir.

15 GEOTHERMAL ENERGY↗