Search NASA⌕ Search

Engineering topics

Bauer, D.

Publications and source records attributed to Bauer, D..

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c 2 . The most stringent limit is set for spin-independent scattering at 36 GeV/c 2 , rejecting cross sections above 9.2×10 –48 cm 2 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic production of 37 Ar in the context of the LUX-ZEPLIN experiment

We estimate the amount of 37 Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting 37 Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of 37 Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average 37 Ar activity after 10 tons are purified and transported underground is 0.058 − 0.090 𝜇⁢Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic 37 Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of 37 Ar should be considered when planning for future liquid-xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10 -48 cm 2 for a WIMP mass of 40 GeV/c 2 and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Projected sensitivity of the LUX-ZEPLIN experiment to the two-neutrino and neutrinoless double $\beta$ decays of $^{134}$Xe

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of 134 Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of 134 Xe, for which xenon detectors enriched in 136 Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7 x 10 24 years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7 x 10 23 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3 x 10 24 years at 90% CL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2020 Site Environmental Report

In 2020, the United States was impacted by the coronavirus (COVID-19) pandemic, resulting in severe illness and death for millions in the United States and globally, interruption of economies and livelihoods, and the dramatic development of vaccines to fight the pandemic. As with many businesses in the U.S. and worldwide, the impact for Brookhaven National Laboratory was significant, with two-thirds of its employees working from home and many operations delayed or stunted. Remarkably, though, the Lab has maintained operations throughout the pandemic, with hundreds of employees working on site as essential staff to run scientific facilities and other mission-critical operations.

54 ENVIRONMENTAL SCIENCES↗

Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1–2) ×10−12 pb at a WIMP mass of 40 GeV/ c 2 . This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10 –48 cm 2 for a WIMP mass of 40GeV/c 2 and a 1000 days exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗