Investigation of CrMnV and CrMnTiV multi principal element alloys thin films for use as exit windows of electron beam accelerators

Here, this study explores CrMnV and CrMnTiV multi principal element alloy (MPEA) films as candidates for electron beam exit windows in industrial, high-power accelerators. Films were deposited via magnetron sputtering on various substrates and exposed to 66 kGy of 10 MeV e-beam irradiation. Structural and mechanical properties were analyzed using FESEM, XRD, and nanoindentation. CrMnTiV films exhibited superior grain uniformity and hardness, regardless of the substrate type. Compared to bulk materials, both MPEA films demonstrated higher hardness and excellent radiation resistance. These results highlight the potential of MPEA films as durable, radiation-tolerant materials for high-performance accelerator exit window applications.

Electron Beam Irradiation↗

Effects of electron beam irradiation on CrMnV and CrMnTiV high entropy alloys: Nano-mechanical, structural, and thermodynamic perspectives

Beam exit windows are crucial components of any particle accelerator as they provide an interface between the beamline vacuum and target material at atmospheric media. For high beam power machines, special materials and designs are required to withstand high radiation and mechanical loads, while minimizing energy loss during transition and maximizing window lifetime. This research investigates the impact of electron beam exposure to bulk CrMnV and CrMnTiV high entropy alloys (HEAs) with the primary goal of identifying suitable candidate materials for the design of robust and durable exit window settings. The selection criteria include intrinsic characteristics, power dissipation, and mechanical responses. According to the thermodynamic calculations, both equiatomic CrMnV and the addition of 7% of Ti with equiatomic CrMnV yield solid-solutions phases. The structural and mechanical properties of CrMnV and CrMnTiV samples were tested using field emission scanning electron microscopy, atomic force microscopy, scanning electron microcopy with energy dispersive x-ray spectroscopy, x-ray diffraction, and nanoindentation before and after exposure to a dose of ~66 kGy from a 10 MeV e-beam accelerator. Despite exhibiting beam transmission characteristics comparable to Cr and V, the indentation hardness of HEAs exceeded that of the Cr and V samples by five to six times. The examination of the CrMnTiV irradiated samples revealed organized deformation patterns depicting new features, which we suspect twinning and twin boundaries due to the addition of Ti to CrMnV. Ti, a hexagonal-close-packed crystal structure, is commonly known for deformation twinning behavior.

36 MATERIALS SCIENCE↗

USING E-BEAM IRRADIATION BEAMLINE AT JEFFERSON LAB TO REMOVE 1,4-DIOXANE AND PFAS IN WASTEWATER

The designed e-beam irradiation beamline [1] at Jefferson Lab has been commissioned and applied to study the degradation removal of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater by collaborating with Hampton Roads Sanitation District (HRSD), treating wastewater in southeast Virginia. The absorbed dose and dose distribution in the entire sample were achieved innovatively using Monte-Carlo simulations that were calibrated with opti-chromic dosimeter rods directly exposed to the e-beam. This research could be a stepstone to the future MW compact SRF accelerator [2] for wastewater remediation.

Li, X.↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

HIGH VOLTAGE DESIGN AND EVALUATION OF WIEN FILTERS FOR THE CEBAF 200 keV INJECTOR UPGRADE

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require highly spin-polarization electron beams, produced from strained super-lattice GaAs photocathodes, activated to negative electron affinity in a photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector defines the orientation of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming MOLLER experiment requires increasing the electron beam energy to 200 keV, to reduce unwanted helicity correlated intensity and position systematics and provide precise control of the polarization orientation. Our contribution describes design, fabrication and testing of the high voltage system to upgrade the Wien spin rotator to be compatible with the 200 keV beam. This required Solidworks modeling, CST and Opera electro- and magnetostatic simulations, upgrading HV vacuum feedthroughs, and assembly techniques for improving electrode alignment. The electric and magnetic fields required by the Wien condition and the successful HV characterization under vacuum conditions are also presented.

Palacios-Serrano, G.↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗