Search NASA⌕ Search

Engineering topics

Baxter, Daniel

Publications and source records attributed to Baxter, Daniel.

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating the Phonon Collection Efficiency in Kinetic Inductance Phonon-Mediated Detectors

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for two existing detector architectures to study phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements.

Dang, Stella Q.↗

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for a KIPMD currently operated at the Northwestern EXperimental Underground Site (NEXUS).

Dang, Stella Q.↗