Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness of Advanced Three Fluid Heat and Mass Exchanger

Advanced internally-cooled membraned-based heat and mass exchangers (HMX), which accounts for three separate fluid streams, are capable of utilizing the sensible and latent heat removed from spacecooling to heat water. The technology provides a unique approach of enhancing the efficiency and cost effectiveness of future HVAC equipment. This paper aims to numerically identify and understand the impact of geometric size, operation conditions, and membrane properties on the overall effectiveness of three-fluid HMXs. The simulations are based on an ORNL in-house open-source HMX model which is capable of simulating such three-fluid HMX components for various flow patterns. The results are expected to enable detailed configuration evaluation and provide in-depth understanding of optimal three-fluid HMX performance at cost effectiveness.

Gao, Zhiming↗

Clean and High-Efficiency Natural Gas Furnace with Advanced Acidic Gas Trap Technology

Ccurrent natural gas condensing furnaces generate substantial acidic condensate and SOx/NOx/CO/HC/methane emissions, causing long-term environment issues related to air, water and soil. Acidic condensate occurs when flue gases within the furnaces cool down below the dew points of acidic gases, which upon condensation, combine with water vapor to produce acidic solutions. The acidic condensate causes serious corrosion and fouling problems in natural gas condensing furnaces. This paper presents a novel solution to use an advanced adsorption technology based on monolithic acidic gas trap (AGT) adsorbers for SOx trapping, NOx redox, and formic acid/CO/HC/methane oxidation, enabling a new natural gas furnace with utra-clean flue gas and neutral condensate. When the AGT adsorber is appropriately integrated with natural gas furnaces, the acidic gases of SOx, NOx and formic gas/CO/HC will be continuously adsorbed, redoxed or oxidized, respectively, from the flue gas during a regular heating season, except for occasional regeneration activities for SOx trapping. In the paper, we present results from a prototype furnace employing the novel AGT component, which enables a pH of the condensate =7, NOx emissions of 1-2 nanograms/joule and an annual fuel utilization efficiency (AFUE) of 96%, providing a cost-effective technology for condensing furnaces that is eco-friendly to the environment.

Gao, Zhiming↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗