Search NASA⌕ Search

Engineering topics

Becker, D.

Publications and source records attributed to Becker, D..

At least 91 records · Page 5

Amplitude analysis and branching fraction measurement of the decay $D_s^{+} → K^+π^+π^-$

Using 6.32 fb -1 of e + e - collision data collected at the center-of-mass energies between 4.178 and 4.226 GeV with the BESIII detector, we perform an amplitude analysis of the decay D$^+_s$ → K + π + π - and determine the amplitudes of the various intermediate states. The absolute branching fraction of D$^+_s$ → K + π + π - is measured to be (6.11 ± 0.18 stat. ± 0.11 syst. ) x 10 -3 . The branching fractions of the dominant intermediate processes D$^+_s$ → K + ρ 0 , ρ 0 → π + π - and D$^+_s$ → K*(892) 0 π + , K*(892) 0 → K + π - are determined to be (1.96 ± 0.19 stat . ± 0.23 syst. ) x 10 -3 and (1.85 ± 0.12 stat . ± 0.13 syst .) x 10 -3 , respectively. The intermediate resonances f 0 (500), f 0 (980), and f 0 (1370) are observed for the first time in this channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross section measurements of the processes $e^+e^–$ → $ωπ^0$ and $ωη$ at center-of-mass energies between 3.773 and 4.701 GeV

The Born cross sections of the processes $e^+e^–$ → $ωπ^0$ and $e^+e^–$ → $ωη$ are measured at center-of-mass energies between 3.773 and 4.701 GeV using a total integrated luminosity of 22.7 fb –1 collected with the BESIII detector operating at the BEPCII collider. A simple $s^{-n}$ dependence for the continuum process can describe the measured Born cross sections. No significant contributions from the ψ(4160), Y(4230), Y(4360), ψ(4415), Y(4660) resonances are found, which indicates relative small branching fractions for these resonances into the $ωπ^0$ and $ωη$ final states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of e + e – → $\mathrm{K^+K^–π^0}$ cross section and observation of a resonant structure

Based on collision data collected by the BESIII detector at the BEPCII collider at center-of-mass energies from 2.000 to 3.080 GeV, a partial-wave analysis is performed for the process $e^+e^–$→ $K^+K^–π^0$. The Born cross section of the process $e^+e^–$→ $K^+K^–π^0$ and its subprocesses $e^+e^–$ → $\phi π^0, K^{*+}$(892)$K^–$ and $K^{*+}_{2}$(1430)$K^–$ are measured. The results for $e^+e^–$→ $K^+K^–π^0$ and $\phi π^0$ are consistent with the BaBar measurements and with improved precision. By analyzing the cross sections of the subprocesses $e^+e^–$ → $K^{*+}$(892)$K^–$ and $K^{*+}_{2}$(1430)$K^–$ a structure with mass $M_R$ = (2190 ± 19 ± 37) MeV/c 2 and width $Γ_R$ = (191 ± 28 ± 60) MeV is observed with a combined statistical significance of 7.1σ. The measured resonance parameters suggest it can be identified as the $\phi$(2170), thus the results provide valuable input to understand the internal nature of this state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross section measurements of the $e^+e^–$ → $D^{*+}D^{*–}$ and $e^+e^–$ → $D^{*+}D^{–}$ processes at center-of-mass energies from 4.085 to 4.600 GeV

The Born cross sections of the $e^+e^–$ → $D^{*+}D^{*–}$ and $e^+e^–$ → $D^{*+}D^{–}$ processes are measured using $e^+e^–$ collision data collected with the BESIII experiment at center-of-mass energies from 4.085 to 4.600 GeV, corresponding to an integrated luminosity of 15.7 fb -1 . The results are consistent with and more precise than the previous measurements by the Belle, Babar and CLEO collaborations. The measurements are essential for understanding the nature of vector charmonium and charmonium-like states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of light backgrounds from relativistic electrons in air light-guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Moller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Moller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

passbands↗