Search NASA⌕ Search

Engineering topics

Beede, William L

Publications and source records attributed to Beede, William L.

Design and Test of Mixed-flow Impellers IV : Experimental Results for Impeller Models MFI-1 and MFI-2 with Changes in Blade Height

Modifications A and B of impeller model MFI-1 and A, B, and C of impeller model MFI-2 were investigated experimentally in an attempt to determine what allowance in blade height should be made for boundary layer and viscous losses in an impeller designed for isentropic compressible flow. A gradual increase in blade height was arbitrarily made from inlet to outlet in anticipation of a gradual build-up of boundary layer. Apparently there was a rapid build-up of boundary layer near the inlet in the experimental case rather than a gradual one. Therefore, the proper allowance for boundary layer cannot be described from the data obtained. Decreasing the pressure gradient along the shroud by reducing the blade height allowance apparently did little to increase the overall efficiency. At the design speed of 1400 feet per second, the overall adiabatic efficiency was increased from 0.83 for the MFI-1A to 0.85 for the MFI-1B with reduction in height; however, it is indicated from the theoretical velocity distribution and outlet surveys that the increase was due to a change from decelerating to accelerating flow along the hub rather than from any change along the shroud. It is further indicated that the consequences of a thickened or separated boundary layer depend not only on the design velocity gradients but also on the shape of the passage.

Hamrick, Joseph T↗

Design and Test of Mixed-flow Impellers III : Design and Experimental Results for Impeller Model MFI-2A and Comparison with Impeller Model MFI-1A

A mixed-flow impeller was designed to give a prescribed blade-surface velocity distribution at mean blade height for a given hub-shroud profile. The blade shape at mean blade height, which was produced by the prescribed velocity distribution, was extended by means of radial lines to form the composite blade shape from hub to shroud. The resulting blade was relatively thick; therefore, it was necessary to retain the inverse blade taper which resulted from extension of the radial lines in order to prevent merging or near merging of the separate blades near the hub. For the first test version of the impeller, designated the MFI-2A, the blade height was arbitrarily made greater than that for the basic impeller (the MFI-2) to allow for viscous effects. At design equivalent speed of 1400 feet per second the peak pressure ratio and maximum adiabatic efficiency were 3.95 and 79 percent, respectively. The adiabatic efficiency of the MFI-2A is four points lower than that for impeller model MFI-1A, but because of the higher slip factor for the MFI-2A, the pressure ratios are approximately equal. The procedures followed in the design of the MFI-1A and MFI-2A were, in general, the same; and, although the prescribed initial condition resulted in geometrical configurations that were quite dissimilar, the resulting performance characteristics compare favorably with designs for which considerable development work has been necessary.

COMPRESSION AND COMPRESSORS↗

Design and Test of Mixed-flow Impellers II : Experimental Results, Impeller Model MFI-1A

An investigation was conducted to determine the performance characteristics of a mixed-flow impeller which was designed with special emphasis on the reduction or elimination of flow decelerations along wetted surfaces. The performance was investigated over a range of equivalent impeller speeds from 700 to 1600 feet per second and over a range of flow rates from maximum adiabatic temperature-rise efficiency, measured at 1-1/2 impeller diameters in a vaneless diffuser, at the design speed of 1400 feet per second were 4.00 and 0.83, respectively.

THEORY AND EXPERIMENT↗

Evaluation of centrifugal compressor performance with water injection

The effects of water injection on a compressor are presented. To determine the effects of varying water-air ratio, the compressor was operated at a constant equivalent impeller speed over a range of water-air ratios and weight flows. Operation over a range of weight flows at one water-air ratio and two inlet air temperatures was carried out to obtain an indication of the effects of varying inlet air temperature. Beyond a water-air ratio of 0.03 there was no increase in maximum air-weight flow, a negligible rise in peak total-pressure ratio, and a decrease in peak adiabatic efficiency. An increase in inlet air temperature resulted in an increase in the magnitude of evaporation. An analysis of data indicated that the magnitude of evaporation within the compressor impeller was small.

COMPRESSORS - RADIAL FLOW↗