Search NASA⌕ Search

Engineering topics

Beeman, J.

Publications and source records attributed to Beeman, J..

X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

Bolometric detector systems for IR and mm-wave space astronomy

Recent developments in bolometric detector systems for millimeter and submillimeter wave space astronomy are described. Current technologies meet all the requirements for the high frequency instrument onboard the cosmic background radiation anisotropy satellite/satellite for the measurement of background anisotropies (COBRAS/SAMBA) platform. It is considered that the technologies that are currently being developed will significantly reduce the effective time constant and/or the cooling requirements of bolometric detectors. These technologies lend themselves to the fabrication of the large format arrays required for the Far Infrared and Submillimeter Space Telescope (FIRST). The scientific goals and detector requirements of the COBRAS/SAMBA platform that will use infrared bolometers are reviewed and the baseline detector system is described, including the feed optics, the infrared filters, the cold amplifiers and the warm readout electronics.

Church, S. E.↗

Feasibility of KTa(1-x)Nb(x)O3 as a dielectric or pyroelectric microcalorimeter

We are developing a dielectric microcalorimeter for X-ray spectroscopy. We will present the results of our measurement of the dielectric permittivity, the spontaneous polarization, and the pyroelectric coefficient of the mixed-crystal quantum ferroelectric KTa(1-x)Nb(x)O3 with a doping of x = 0.012, as a function of temperature and bias voltage across the device. The effects of surface layers on the permittivity and the pyroelectric coefficient are discussed. We also show the signal results from infrared LED and alpha-particle radiation.

Pfafman, T. E.↗

Bragg crystal polarimeter for the Spectrum-X-Gamma mission

A Bragg crystal polarimeter for the focal plane of the SODART telescope on the Spectrum-X-Gamma mission is being designed. A mosaic graphite crystal will be oriented at 45 deg to the optic axis of the telescope, thereby preferentially reflecting those X-rays which satisfy the Bragg condition and have electric vectors that are perpendicular to the plane defined by the incident and reflected photons. The reflected X-rays will be detected by an imaging proportional counter with the image providing direct X-ray aspect information. The crystal will be about 50 microns thick to allow X-rays with energies of 4 keV or greater to be transmitted to a lithium block mounted below the graphite. The lithium is used to measure the polarization of these high energy X-rays by exploiting the polarization dependence of Thomson scattering. The development of thin mosaic graphite crystals is discussed and recent reflectivity, transmission, and uniformity measurements are presented.

Holley, J.↗

A new thermal sensor for X-ray microcalorimetry

A concept for a detector is introduced which exploits the significant temperature dependence of the dielectric constant in ferroelectric materials. The concept permits the use of a microcalorimeter without the resistive sensors which are associated with heat dissipation and increased Johnson noise in the electronic conversion circuit. General calorimeter features are listed, and the concepts related to dielectric calorimeters are discussed in terms of operational and detection advantages. The use of the device is delineated both theoretically and experimentally with the results of an operational dielectric material. The mixed-crystal quantum ferroelectric is employed and detects 6 MeV alpha particles while operating at 1.2 K in the first detection conducted. The temperature dependence of the dielectric constant in the materials allows for the elimination of resistive sensors in microcalorimeters, thereby improving the ultimate sensitivity of the instrument.

Silver, Eric↗

Test results of a prototype dielectric microcalorimeter

The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

Pfafman, T. E.↗