Search NASASearch

Engineering topics

Beeman, J. W.

Publications and source records attributed to Beeman, J. W..

A report on laboratory performance of the spectroscopic detector arrays for SPIRE/HSO

We report the performance of the flight bolometer arrays for the Spectral and Photometric Imaging REceiver (SPIRE) instrument to be on board of the Herschel Space Observatory (HSO). We describe the test setup for the flight Bolometric Detector Assembly (BDA) that allows the characterization of its performance, both dark and optical, in one instrument’s cool down. We summarize the laboratory procedure to measure the basic bolometer parameters, optical response time, optical efficiency of bolometer and feedhorn, dark and optical noise, and the overall thermal conductance of the BDA unit. Finally, we present the test results obtained from the two flight units, Spectroscopic Long Wavelength (SLW) and Spectroscopic Short Wavelength (SSW).

Hargrave, P. C.

Extrinsic germanium photoconductors for far-IR astronomy: Research results and works in progress

Some Ge:Ga and Ge:Sb photoconductor materials and detectors that are currently under development are reported. The best Ge:Ga devices exhibit dark currents of lower than 200 electrons/s, with a concurrent responsivity of 2 A/W and a detective quantum efficiency (DQE) of 5 percent. For higher backgrounds, an operating temperature of 3 K can be used. This increases the DQE to 7 percent and the responsivity to 4.5 A/W. Investigations were initiated into n-type Ge:Sb as an alternative photoconductive material. Two crystals of Ge:Sb were grown and a number of test detectors were fabricated and evaluated. At 2 K, the best device produced dark currents of less than 100 electrons/s with concurrent responsivity of 1 A/W and DQE of 4 percent, and at 3 K, produced currents of 10(exp 5) electrons/s with a DQE of 7 percent and a responsivity of 4 A/W. Using p-type Ge:Ga crystals, two dimensional monolithic photoconductor arrays are being constructed. Future work will focus on measuring pixel-to-pixel homogeneity, cross talk issues, overall sensitivity and suitability for photometric instruments.

Beeman, J. W.

Neutron Transmutation Doped (NTD) germanium thermistors for sub-mm bolometer applications

Recent advances in the development of neutron transmutation doped (NTD) semiconductor thermistors fabricated from natural and controlled isotopic composition germanium are reported. The near ideal doping uniformity that can be achieved with the NTD process, the device simplicity of NTD Ge thermistors and the high performance of cooled junction field effect transistor preamplifiers led to the widespread acceptance of these thermal sensors in ground-based, airborne and spaceborne radio telescopes. These features made possible the development of efficient bolometer arrays.

Haller, E. E.

Infrared bolometers with silicon nitride micromesh absorbers

Sensitive far infrared and millimeter wave bolometers fabricated from a freestanding membrane of low stress silicon nitride are reported. The absorber, consisting of a metallized silicon nitride micromesh thermally isolated by radial legs of silicon nitride, is placed in an integrating cavity to efficiently couple to single mode or multiple mode infrared radiation. This structure provides low heat capacity, low thermal conduction and minimal cross section to energetic particles. A neutron transmutation doped Ge thermister is bump bonded to the center of the device and read out with evaporated Cr-Au leads. The limiting performance of the micromesh absorber is discussed and the recent results obtained from a 300 mK cold stage are summarized.

Bock, J. J.

Testing of 100 mK bolometers for space applications

Electrical and optical performance data are presented for a prototype 100 mK spider-web bolometer operating under very low photon backgrounds. These data are compared with the bolometer theory and are used to estimate the expected sensitivity of such a detector used for low background space astronomy. The results demonstrate that the sensitivity and speed of response requirements of the bolometer instruments proposed for these missions can be met by 100 mK spider-web bolometers using neutron transmutation doped germanium as the temperature sensitive element.

Murray, A. G.

Near-contact diffusion and compensation in extrinsic photoconductors

Carrier diffusion from heavily doped contact regions has been experimentally monitored with resistivity measurements of variable thickness Si:P extrinsic photoconductors (n(+) -n-n(+)). Modeling of free carrier diffusion at the interface of heavily doped contacts and highly resistive bulk at low temperatures predicts extended regions (5-30 microns) of excess carriers in high purity materials so that, in thin device structures, free carrier diffusion profiles from each contact will overlap and determine the resistivity of the device. In this work, a decrease in resistivity of four orders of magnitude was observed in a 5-micron thick structure compared to a 10-micron thick device. The resistivity of an ohmic structure in the thin limit is strongly dependent on the bulk and near-contact compensation, and resistivity measurements can be used as a sensitive measure of compensation at interfaces or in the tail of implanted layers.

Olsen, C. S.

Stressed and unstressed Ge:Ga detector arrays for airborne astronomy

The construction and operation of 2D arrays of both unstressed and stressed Ge:Ga photoconductive detectors for far-IR astronomy from the Kuiper Airborne Observatory is presented. The 25 element (5 x 5) arrays are designed for a new cryogenically cooled spectrometer. The 2D spatial array described has the advantage of absolute registry between pixels in a map.

Stacey, G. J.

The MPE/UCB far-infrared imaging Fabry-Perot interferometer (FIFI)

FIFI, an imaging spectrometer with two or three Fabry-Perot interferometers in a series for astronomical observations in the FIR range, is described. Spectral resolutions of 2 km/s can be obtained with FIFI. Design considerations are discussed as well as optics, the detector array, the transimpedance amplifier array, signal demodulation, data acquisition, and instrument control.

Poglitsch, A.

Ion-implanted extrinsic Ge photodetectors with extended cutoff wavelength

Far-IR Ge detectors fabricated using boron ion implantation are shown to exhibit operating characteristics compatible with requirements for low background applications. Device parameters such as low dark currents, reasonably good sensitivity, and extended wavelength threshold demonstrate that ion-implanted Ge far-IR detectors offer promise for use in astrophysics instrumentation.

Wu, I. C.

Improved low frequency stability of bolometric detectors

An ac bridge readout system has been developed that greatly improves the low-frequency stability of bolometric detectors. The readout can be implemented with a simple circuit appropriate for use in space applications. A matched pair of detectors was used in the readout to achieve system noise within a factor of two of the fundamental noise limit of the detectors at frequencies as low as 10 mHz. The low-frequency stability of the readout system allows slower, more sensitive detectors to be used in many applications, and it facilitates observing strategies that are well suited to spaceborne observations.

Wilbanks, T.

Stressed Ge:Ga photoconductors for space-based astronomy. (Is there life beyond 120 micron)

Information is given in viewgraph form. Information is given on the characteristics of stressed Ge:Ga, a spring type stress cavity, mounting hardware, materials parameters affecting dark current, and the behavior of low dark current stressed Ge:Ga. It is concluded that detectors exist today for background-limited detection at 200 microns, that researchers are narrowing in on the significant parameters that effect dark current in stressed photoconductors, that these findings may be applied to other photoconductor materials, and that some creative problem solving for an ionizing effect reset mechanism is needed.

Beeman, J. W.

Germanium Blocked Impurity Band (BIB) detectors

Information is given in viewgraph form. The advantages of the Si blocked impurity band (BIB) detector invented by M. D. Petroff and M. G. Stabelbroek are noted: smaller detection volume leading to a reduction of cosmic ray interference, extended wavelength response because of dopant wavefunction overlap, and photoconductive gain of unity. It is argued that the stated advantages of Si BIB detectors should be realizable for Ge BIB detectors. Information is given on detector development, subtrate choice and preparation, wafer polising, epitaxy, characterization of epi layers, and preliminary Ge BIB detector test results.

Haller, E. E.

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.

Stressed detector arrays for airborne astronomy

The development of stressed Ge:Ga detector arrays for far-infrared astronomy from the Kuiper Airborne Observatory (KAO) is discussed. Researchers successfully constructed and used a three channel detector array on five flights from the KAO, and have conducted laboratory tests of a two-dimensional, 25 elements (5x5) detector array. Each element of the three element array performs as well as the researchers' best single channel detector, as do the tested elements of the 25 channel system. Some of the exciting new science possible with far-infrared detector arrays is also discussed.

Stacey, G. J.

An ac bridge readout for bolometric detectors

The authors have developed a bolometer readout circuit which greatly improves the low-frequency stability of bolometric detectors. The circuit uses an ac bias voltage and two matched bolometers and allows stable dc bolometer operation for integration times greater than 10 s. In astronomical applications the readout allows for qualitatively different observation modes (e.g. staring or slow-drift scanning) which are particularly well suited for space observations and for the use of arrays. In many applications the readout can increase sensitivity. The authors present noise spectra for 4He temperature bolometers with no excess noise at frequencies greater than 0.1 Hz. The measured optical responsivity of a bolometer operated with the present readout is the same as that of a bolometer operated with a conventional readout.

Rieke, F. M.

Stressed photoconductive detector for far-infrared space applications

An optimized leaf-spring apparatus for applying uniaxial stress to a Ge:Ga far-IR photoconductor has been designed and tested. This design has significant advantages for space applications which require high quantum efficiency and stable operation over long periods of time. The important features include adequate spring deflection with relatively small overall size, torque-free stress, easy measurement of applied stress, and a detector configuration with high responsivity. One-dimensional arrays of stressed photoconductors can be constructed using this design. A peak responsivity of 38 A/W is achieved in a detector with a cutoff wavelength of 200 microns, which was operated at a temperature of 2.0 K and a bias voltage equal to one-half of the breakdown voltage.

Wang, J.-Q.

Optical efficiency of far-infrared photoconductors

The present optimization of the geometry of far-IR photoconductive detectors with diffraction-limited throughput, on the basis of experimental and theoretical results, gives attention to the internal optical path relative to measured absorption length, photoconductive gain, uniformity of illumination, cosmic ray cross section, and design compatibility with the requirements of one- and two-dimensional arrays. It is demonstrated that a rod-shaped, square cross section detector geometry, having lateral face electrodes and a beveled backface with which to trap the radiation by total internal reflection, exhibits responsivity commensurate with that of the best available detectors in integrating cavities.

Wang, J.-Q.