Search NASA⌕ Search

Engineering topics

Behbehani, K.

Publications and source records attributed to Behbehani, K..

Dynamic regulation of heart rate during acute hypotension: new insight into baroreflex function

To examine the dynamic properties of baroreflex function, we measured beat-to-beat changes in arterial blood pressure (ABP) and heart rate (HR) during acute hypotension induced by thigh cuff deflation in 10 healthy subjects under supine resting conditions and during progressive lower body negative pressure (LBNP). The quantitative, temporal relationship between ABP and HR was fitted by a second-order autoregressive (AR) model. The frequency response was evaluated by transfer function analysis. Results: HR changes during acute hypotension appear to be controlled by an ABP error signal between baseline and induced hypotension. The quantitative relationship between changes in ABP and HR is characterized by a second-order AR model with a pure time delay of 0.75 s containing low-pass filter properties. During LBNP, the change in HR/change in ABP during induced hypotension significantly decreased, as did the numerator coefficients of the AR model and transfer function gain. Conclusions: 1) Beat-to-beat HR responses to dynamic changes in ABP may be controlled by an error signal rather than directional changes in pressure, suggesting a "set point" mechanism in short-term ABP control. 2) The quantitative relationship between dynamic changes in ABP and HR can be described by a second-order AR model with a pure time delay. 3) The ability of the baroreflex to evoke a HR response to transient changes in pressure was reduced during LBNP, which was due primarily to a reduction of the static gain of the baroreflex.

Clinical Trial↗

Sensor/actuator failure detection for turbofan engines

A procedure for sensor/actuator failure detection using a generalized likelihood ratio (GLR) test is described. The GLR concept can provide a reliable evaluation of failure occurence when associated with a feedback control design which does not require sensor outputs to provide data estimates. A GLR detector was developed and tested.

Behbehani, K.↗

Sensor failure and multivariable control for airbreathing propulsion systems

A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

Behbehani, K.↗

Sensor/actuator failure detection and isolation for airbreathing propulsion systems

In this paper, the Generalized Likelihood Ratio (GLR) test is used to detect and isolate sensor and/or actuator failures when a digital computer simulation model of the physical system is available. The input to the GLR detector is an innovation sequence formed by subtracting the model outputs from the sensed outputs. Application of the GLR detector to the General Electric QCSEE turbofan engine demonstrates the utility of the proposed procedure.

Leininger, G. G.↗