Search NASA⌕ Search

Engineering topics

Beiersdorfer, P.

Publications and source records attributed to Beiersdorfer, P..

At least 19 records

Electron collisional excitation cross-section measurements and modeling for select Ni-like to Ge-like gold transitions

We have experimentally determined the electron collisional excitation cross-sections for several 3d→4f and 3d→5f excitations in Ni- to Ge-like Au at energies of ~ 0.4, 1, 2, and 3 keV above threshold energy, E T , for the 3d→4f excitations ( E T ~ 2.5 keV) and ~ 0.2, 1, and 2 keV above threshold energy for the 3d→5f excitations ( E T ~ 3.3 keV). The cross-section measurements are possible by using the GSFC micro-calorimeter to record emission spectra from beam plasmas created in the Livermore EBIT-I electron beam ion trap. The cross-sections are experimentally determined from the ratio of the measured intensities of the collisionally excited lines to the intensities of the radiative recombination lines in monoenergetic electron distribution EBIT-I plasmas. The effects of polarization and Auger processes in the beam plasmas are accounted for in the cross-section determination. Experimentally determined cross-sections are compared with those from HULLAC, DWS, and FAC calculations. Finally, the measurements exhibit significant differences with the calculations of these excitation cross-sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements of the L-shell X-ray emission of fluorine-like europium

Measurements of the L-shell X-ray emission of fluorine-like europium ions (Eu 54+ ) were made under controlled laboratory conditions on the EBIT-I electron beam ion trap at Livermore using an X-ray calorimeter, extending such measurements to the middle of the rare earth elements. Comparing the calorimeter spectra with atomic data from the flexible atomic code, we have identified and analyzed several prominent n = 3 → n = 2 transitions, including one two-electron, one-photon core changing transition and one electric quadrupole transition. We find that the measured energies are typically up to several eV higher than predicted.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emission Lines of Fe xiv, Fe xv, and Fe xvi in the Extreme Ultraviolet Region 40–100 Å

We report on emission spectra of iron in the extreme ultraviolet recorded at an electron density of ~10 11 cm -3 on the Lawrence Livermore electron beam ion trap facility. We present a summary of the observed emission lines, including wavelengths and emission intensities, and present spectra of pure Fe xiv through Fe xvi emission derived from our measurements in the 40–100 Å wavelength range. We show that spectral models, especially the current version of CHIANTI v10.0, describe the M-shell emission from these three charge states of iron reasonably well, and we are able to verify several transitions in CHIANTI for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

Measurements of inner-shell excited levels of Na-, Mg-, and Al-like europium on the LLNL EBIT

We report on a measurement of several n = 3 → n = 2 inner-shell transitions in sodiumlike, magnesiumlike, and aluminumlike europium, performed at the EBIT-I electron beam ion trap facility at the Lawrence Livermore National Laboratory using an x-ray calorimeter. Although the inner-shell x-ray lines of such M-shell ions are typically dominated by electric dipole allowed transitions, we have also identified a weak feature that appears to be the result of electric quadrupole decay in sodiumlike Eu 52+ . Here, we compare the measured transitions energies to the calculated values obtained using the flexible atomic code. We find agreement in most cases within 2 eV or better.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transition energy measurements of the X-ray lines of neon-like europium

Here, we report the measurements of the n = 3 → n = 2 L-shell X-ray transitions of neon-like Eu 53+ . These include all seven allowed electric dipole (E1) transitions, five electric quadrupole (E2) transitions, and one magnetic quadrupole (M2) transition. The measurements were carried out at the EBIT-I electron beam ion trap facility at Livermore using an X-ray calorimeter. The measured values agree with many-body perturbation theory calculations within the experimental uncertainties. This includes the transitions that involve a 2s electron and that are, therefore, strongly affected by quantum electrodynamical effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements and calculations of 2 s – 2 p transitions in neonlike germanium: Achieving agreement at the 10 – 4 level

Calculations that achieve spectroscopic accuracy, i.e., at the level of 10 –4 or better, are rare and typically restricted to few-electron systems. Here we present high-resolution grating spectrometer measurements of 11 2s 1/2 – 2p 3/2 transitions in neonlike Ge 22+ that distinguish between two different implementations of the many-body perturbation theory (MBPT) method, including our own. The measurements show that our implementation of the MBPT method consistently achieves spectroscopic accuracy at the 10 –4 level for all of the measured lines. Moreover, our calculations improve the 10 –3 accuracy of prior MBPT calculations by an order of magnitude and allow us to make greatly improved predictions of the location of potential photopumped lines in Ge 22+ . Here, the measurements also improve on previous measurements of 2s 1/2 – 2p 3/2 transitions in fluorinelike Ge 23+ and oxygenlike Ge 24+ . Measurements of n = 2 to n = 3 transitions in Al 7+ , Al 8+ , and Al 9+ are used to support our measurement accuracy at the 10 –5 level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polarization measurements of Ne-like Mo 32+ x-ray lines excited by an electron beam

We present polarization measurements of the $2{{\rm{p}}}^{5}3{\rm{d}}$ 1 P 1 → 2p 6 1 S 0 resonance line of Ne-like Mo 32+ , commonly known as 3C, as well as the $2{{\rm{p}}}^{5}3{\rm{d}}$ 3 D 1 → 2p 6 1 S 0 intercombination line, commonly known as 3D, as a function of the electron impact energy ranging from near threshold to 6 times threshold (2.75–15 keV). In addition, the x-ray line polarization of the $2{{\rm{p}}}^{5}3{\rm{p}}$ 3 D 2 → 2p 6 1 S 0 electric quadrupole forbidden line was measured at 3 and 4 keV. Excitation of these lines was achieved with the LLNL EBIT-I electron beam ion trap. The degree of polarization of the emission lines was derived by comparing spectra recorded with a flat Ge (111) crystal spectrometer, which is sensitive to polarization, to the spectra recorded by an x-ray calorimeter, which is insensitive to polarization. Here, the experimental measurements were compared to theoretical predictions produced using the Flexible Atomic Code, and good agreement was found.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of He-like Satellite Lines of the H-like Potassium K xix Emission

We present measurements of the H-like potassium (K xix) X-ray spectrum and its He-like (K xviii) satellite lines, which are situated in the wavelength region between 3.34 and 3.39 Å, which has been of interest for the detection of dark matter. The measurements were taken with a high-resolution X-ray spectrometer from targets irradiated by a long-pulse (2 ns) beam from the Orion laser facility. Here, we obtain experimental wavelength values of dielectronic recombination satellite lines and show that the ratio of the Lyα lines and their dielectronic satellite lines can be used to estimate the electron temperature, which in our case was about 1.5 ± 0.3 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution measurements of Cl 15 + line shifts in hot, solid-density plasmas

The shifts of the 1s3p 1 P 1 → 1s 2 1 S 0 He-β transition of Cl 15+ were measured in hot (≥ 600 eV), dense (1–2 g/cm 3 ) plasmas generated by a (66–151)-J short-pulse laser beam at the Orion laser facility. The subpicosecond laser beam irradiated optically thin, KCl microdot targets buried in layers of plastic. The measured red shifts ranged from 4.8 ± 1.1 eV for unshocked to 5.9 ± 1.2 eV for shocked targets. Furthermore, these values are significantly smaller than recent predictions from a self-consistent-field ion-sphere model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution Charge Exchange Spectra with L-shell Nickel Show Striking Differences from Models

This work reports on the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H 2 and He. We employ the commonly used charge exchange models found in xspec and spex, acx and spex-cx, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. Specifically, we find that configuration mixing may play an important role in generating lines from core-excited states, and may be improperly treated in models. These conclusions imply that if applied to astrophysical data, these models may lead to incorrect assumptions of the physical and chemical parameters of the region of interest.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas

The Orion high-resolution x-ray (OHREX) spectrometer has been a successful tool for measuring the shapes of density-broadened spectral lines produced in short-pulse heated plasmas at the Orion laser facility. We have recently outfitted the instrument with a charge-couple device (CCD) camera, which greatly increased the accuracy with which we can perform line-shift measurements. Because OHREX is located on the outside of the Orion target chamber, no provisions for the shielding of electromagnetic pulses are required. With the CCD, we obtained a higher signal-to-noise ratio than we previously obtained with an image-plate detector. As a result, this allowed us to observe structure in the image produced by the diffraction from the two OHREX crystals, which was highly reproducible from shot to shot. This structure will ultimately limit the accuracy of our spectroscopic measurements

47 OTHER INSTRUMENTATION↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

Temperature Measurements Using the Dielectronic Satellite Lines of Fe xvii

The coronal temperature of Capella and Procyon has been derived from the spectral emission of Fe XVII observed in high resolution with Chandra's High Energy Transmission Grating Spectrometer. The measurement makes use of well resolved dielectronic satellite features with a spectator electron in the n = 4 shell. This method does not require a priori knowledge of the ionization equilibrium or of the elemental abundances. We find the temperature of Fe XVII emission is ${264}_{-51}^{+142}$ eV for Procyon and ${514}_{-25}^{+27}$ eV for Capella, i.e., 3.1 and 6.0 MK, respectively. As a result, the Procyon measurement is based on three X-rays observed in the dielectronic satellite feature, which illustrates the power of the method even for low-signal observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗