Search NASA⌕ Search

Engineering topics

Bell, K S

Publications and source records attributed to Bell, K S.

Physics of Multi-Planar and Compact Cylindrical Wire Arrays Implosions on University-Scale Z-pinch Generators

The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Spectroscopy Experiments on the 500 kA XP Pulsed-Power Generator

Recent experiments on the 500 kA XP pulsed-power generator at Cornell University have explored the properties of optical spectra in single wires and wire arrays. In the single wire experiments, {approx}1% of the current from XP has been directed through the single wire. Spectra have been recorded using a half-meter spectrometer and a CCD camera located adjacent to the XP pulser. We are studying the visible spectra emitted by the wires and the background light from the machine hardware in order to identify the levels of current per wire for which visible spectroscopy might provide a means to measure magnetic field strength. We have also investigated the dependence of single wire visible spectra on the current, which was measured using a calibrated non-integrating Rogowski coil. UV and XUV diodes were employed to gather information about the temporal structure of the background and wire radiation. The line radiation in the spectra was recorded with wire currents at the few kA level. This is comparable to the first 10 ns of a 32-wire array experiment on 1 Ma generator and a 600-wire array at 20 MA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the Axial Instability in Low Wire Number Wire Array Z-Pinches

We are investigating the development of the axial instability, a modulation of the size of the coronal plasma that develops around each wire in wire-array Z-pinches. The modulation is a result of nonuniform ablation of material from the relatively cold wire core. It has long been known that the wavelength of this modulation is constant late in time and, since it is unique to different materials, it has come to be known as the fundamental mode. In these experiments we imaged individual wires with laser shadowgraphy early in time primarily in low wire number, large wire diameter aluminum arrays for ease of viewing. We Observe the development of this modulation from the time of initiation of coronal plasma, obtaining its dominant wavelength and amplitude growth as a function of time. We also studied the instability on coiled wires, which modify the wire ablation mechanism and completely suppress the fundamental mode[Hall2008]. time is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implosion dynamics and radiation characteristics of wire-array Z pinches on the Cornell Beam Research Accelerator

Experimental results are presented that characterize the implosion dynamics and radiation output of wire-array Z pinches on the 1-MA, 100-ns rise-time Cornell Beam Research Accelerator (COBRA) [J. B. Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]. The load geometries investigated include 20-mm-tall cylindrical arrays ranging from 4 to 16 mm in diameter, and consisting of 8, 16, or 32 wires of either tungsten, aluminum, or Invar (64% iron, 36% nickel). Diagnostics fielded include an optical streak camera, a time-gated extreme-ultraviolet framing camera, a laser shadowgraph system, time-integrated pinhole cameras, an x-ray wide-band focusing spectrograph with spatial resolution, an x-ray streak camera, a load voltage monitor, a Faraday cup, a bolometer, silicon diodes, and diamond photoconducting detectors. The data produced by the entire suite of diagnostics are analyzed and presented to provide a detailed picture of the overall implosion process and resulting radiation output on COBRA. The highest x-ray peak powers (300-500 GW) and total energy yields (6-10 kJ) were obtained using 4-mm-diameter arrays that stagnated before peak current. Additional findings include a decrease in soft x-ray radiation prior to stagnation as the initial wire spacing was changed from 1.6 mm to 785 {mu}m, and a timing correlation between the onset of energetic electrons, hard x-ray generation, and the arrival of trailing current on axis - a correlation that is likely due to the formation of micropinches. The details of these and other findings are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗