Evaluation of catalysts for decomposition of ammonia in hydrogen isotope purification systems
Not Available
Engineering topics
Publications and source records attributed to Belliveau, Raymond G..
Not Available
In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. There have been development efforts to design an all-metal scroll pump design alternative to the Normetex style. The first generation was fabricated out of machined stainless steel, but the thermal management and increased weight were not ideal. To mitigate the weight, an aluminum version was designed. The tritium holdup on untreated aluminum surfaces can be greater than stainless steel, so the wetted aluminum surfaces were electroless plated in nickel and then electroplated in gold. The development effort outlined in this report details the design of an improved version of the stainless steel version.
Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.
This report documents the methods and results of a modeling study on a series of data generated by 1-foot test columns for the Water Detritiation project. In order to compliment modeling work already in progress on this project, a purely empirical curve-fitting approach is used in this study to determine chromatographic performance indicators such as retention time, curve width, and the number of chromatographic stages. The data used in this study comes from four sets of chromatographic test separations performed in March through May of 2017 using 1-foot columns. All are using the same flow rates and temperature (room temperature, nominally 25 C°). The first set of data (referred to in this report as the Column 1 data) is a series of twelve breakthrough curve measurements. Prior to each of these twelve runs, the column was regenerated by flowing hydrogen gas through the column, for increasing amounts of time, ranging from 2 hours to 25 hours. The second set of data (referred to as the Column 2 data) is comprised of five measurements of breakthrough curves measured in similar fashion as the Column 1 data, across a range of regeneration times from 2 to 21 hours. The third set of data (referred to as the Purge data) is of three breakthrough curves, measured after a regeneration time of 8 hours, which takes place after a nitrogen purge of 15, 30, or 45 minutes. The fourth data set is a series of five breakthrough curve measurements using a 2 nd batch of stationary phase, taken after regeneration times ranging from 2 to 20 hours. The overall modeling approach is as follows. First, the data is pre-processed for formatting, artifact removal, and is normalized. The data is then fit by integrated versions of four common chromatographic models. The best model is chosen based on the predictive performance of the model, and chromatographic performance values are calculated based on the best model’s fit parameters. Each of these processes are detailed below.