Search NASA⌕ Search

Engineering topics

Belov, Mikhail E.

Publications and source records attributed to Belov, Mikhail E..

Development of a new ion mobility time-of-flight mass spectrometer

Complex samples require multidimensional measurements with high resolution for full characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometry (IMS-Orbitrap MS) platform. To circumvent the timing difference between the fast IMS separation and the slow Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequence to multiplex ions into the drift tube and Orbitrap. The instrument was designed to operate in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to fully optimize the signal-to-ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data, while a new algorithm was developed for the DM analyses. The new algorithm is a two-step process that first recovers the SM data from the encoded DM data and then decoded the SM data. The algorithm also performs multiple refining procedures in order to minimize the demultiplexing artifacts traditionally observed in such scheme. The new IMS-Orbitrap MS platform was demonstrated for the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

47 OTHER INSTRUMENTATION↗

Rapid Sample Processing For LC-MS Based Quantitative Proteomics Using High Intensity Focused Ultrasounds

A new sample processing workflow that uses high intensity focused ultrasound to rapidly reduce and alkylate cysteines, digest proteins and then label peptides with 18O was developed for quantitative proteomics applications. Each step was individually refined to minimize reaction times, peptide loses and undesired by-products or modifications. By using this novel workflow, mouse plasma proteins were successfully denatured, alkylated, in-solution digested, and 18O labelled in < 10 min for subsequent analysis by liquid chromatography-electrospray ionization high resolution mass spectrometry. Performance was evaluated in terms of the number of mouse plasma peptides and proteins identified in a shotgun approach and the quantitative dynamic range. The results were compared with previously published results obtained using conventional sample preparation methods and were found to be similar. Advantages of the new method include greatly simplified and accelerated sample processing, as well as being readily amenable to automation.

Lopez-Ferrer, Daniel↗