Search NASA⌕ Search

Engineering topics

Bender, Guido

Publications and source records attributed to Bender, Guido.

At least 19 records

Impacts of PTL coating gaps on cell performance for PEM water electrolyzer

The anode porous transport layer (PTL) is a critical component of polymer electrolyte membrane (PEM) water electrolyzers, providing electrical conduction and water/oxygen transport to the anode catalyst layer. Platinum group metal (PGM) coatings are applied to titanium PTLs to prevent oxidation and preserve conductivity. To implement PEM water electrolysis on a large scale, it is essential to minimize the cost of mass-manufactured cell components while ensuring that defects in materials and components do not adversely affect the performance of the cell. In this study, we created gaps in the Pt coatings that are typically applied to PTLs to understand their effects on cell performance and inform on fabrication tolerances. The PTL coatings were fabricated by sputter deposition of Pt, intentionally leaving uncoated regions in either large patches or thin strips. For either geometry, the cell performance decreased with the increasing fraction of the uncoated regions. However, PTLs containing multiple thin uncoated strips caused a less severe performance effect than PTLs with continuous uncoated regions of the same relative total area. Through analysis of cell performance, impedance, and 3D charge transport modelling, here we demonstrate that both the anode catalyst layer and membrane play a role in distributing current to mitigate the impact of coating defects at a short length scale. These results allow to draw conclusions about the tolerance requirements with regards to PTL coating uniformity in terms of both the size and total area of defects.

08 HYDROGEN↗

NREL 25-cm2 High-Pressure Low-Temperature Electrolysis Cell Hardware (Open Source)

This data resource describes an open-source cell hardware that enables low temperature electrolysis (LTE) testing at elevated pressures. Existing commercial options have several downsides when it comes to R&D testing. They are often not designed for repeated reassembly, may not be able to accommodate porous transport layers with different thicknesses, and do not give state-of-the-art performance. Therefore, this hardware was developed specifically with LTE R&D in mind and its design is being made available to the global LTE community. This work was planned and funded by the U.S. Department of Energy's H2NEW consortium (https://h2new.energy.gov/). The hardware design package (.zip file) details the drawings, auxiliary materials, and procedures required to fabricate, assemble, and operate the National Renewable Energy Laboratory's (NREL's) high-pressure low-temperature electrolysis cells. While the hardware itself—end plates, current collectors, flow fields, bolts and washers, tube fittings—is always the same, the assembly and operating procedures may change depending on the active materials being tested, especially for the membrane. Material-specific assembly and operating procedures will be posted to the H2NEW website as they are developed and validated. Disclaimer: The documents and drawings included in this download package describe a design for a low temperature electrolysis hardware that is intended to comply with leak testing according to ASME B31.1. Safe operation at ambient and elevated pressures is the sole responsibility of the end user, which should be evaluated on a case-by-case basis for each individual cell. Factors affecting the sealing capability may depend on, for example, machining quality, cell assembly components, operating conditions, and operating history. Operation at pressure should only be performed on qualified test stands by qualified operators. NREL/ALLIANCE FOR SUSTAINABLE ENERGY, LLC/DOE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND MAKES NO WARRANTY AS TO THE ACCURACY, COMPLETENESS, OR USEFULNESS OF ANY INFORMATION PROVIDED HEREIN. USE OF THIS PACKAGE IS AT THE USER’S OWN RISK.

08 HYDROGEN↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗

Catalyst Layer Resistance and Utilization in PEM Electrolysis

Improving utilization, performance, and stability of low iridium (Ir)-loaded anodes is a key goal to enable widespread adoption of polymer electrolyte membrane water electrolysis (PEMWE) for clean hydrogen production. A potential limitation is high ionic or electronic resistance of the anode catalyst layer, which leads to poor catalyst utilization, increased voltage losses, and high local overpotentials that can accelerate degradation. While catalyst layer resistance is relatively well-understood in fuel cells and other porous electrode systems, characterization of these effects is not as well established in PEMWE research. Here we present in-situ methods for measuring catalyst layer resistance in electrolysis cells using a non-faradaic H 2 /H 2 O condition as well as methods for calculating the associated voltage losses. These methods are applied to anode catalyst layers based on IrO 2 nanoparticles as well as dispersed nano-structured thin film (NSTF) Ir catalysts. Trends with anode catalyst loading and interactions between the porous transport layer and catalyst layer are investigated for IrO 2 anodes. Post-mortem microscopic analysis of durability-tested anodes is also presented, showing uneven degradation of the catalyst layer caused by catalyst layer resistance.

08 HYDROGEN↗

Aging gracefully? Investigating iridium oxide ink's impact on microstructure, catalyst/ionomer interface, and PEMWE performance

Here, in this study, we conducted a thorough investigation of the impact of aging iridium oxide (IrO 2 ) perfluorosulfonic acid ionomer ink for up to 14 days on the properties of the ink and the resulting catalyst layers. We examined ink properties, such as zeta potential, dynamic light scattering (DLS), density, surface tension, and rheology, as functions of ink aging time. To evaluate the microstructure and catalyst/ionomer interface, we employed transmission electron microscopy (TEM), X-ray scattering, and X-ray photoelectron spectroscopy (XPS) techniques. Furthermore, we assessed the effect of ink aging on the performance of proton exchange membrane water electrolyzers (PEMWEs). Our findings reveal that most ink properties remain stable for 14 days. The variations in PEMWE cell performance are minimal, and no clear trend is observed in relation to ink aging time. This study demonstrates that the effects of aging the inks for 14 days on ink properties, catalyst layer structure, catalyst/ionomer interface, and PEMWE performance are negligible, indicating a substantial time window after ink preparation without any significant changes in its properties. These insights provide crucial guidance for the commercial production and coating processes of ink, which is necessary for scaling up PEM technologies to meet future demand.

30 DIRECT ENERGY CONVERSION↗

The impacts of membrane pinholes on PEM water electrolysis

Polymer electrolyte membrane (PEM) water electrolysis is a promising technology to efficiently produce green hydrogen. Irregularities in membrane electrode assembly (MEA) component materials caused by manufacturing, processing, handling, or operation can lead to performance loss and failure. One example is the presence of pinholes in the membrane, which can cause increased gas transport (crossover) and lead to electrical shorting. This work investigates the effects of intentionally introduced pinholes with various sizes up to 350μm in diameter. The presence of the pinholes resulted in minimal impacts on the cell voltage (±30 mV at 4Acm -2 ). However, the pinholes significantly increased H 2 crossover, which decreased hydrogen production efficiency and increased the minimum current density for safe operation. The impacts of the pinhole on the H 2 crossover and efficiency are more severe for open pinhole features than tear-like pinhole features. In conclusion, this research demonstrates that even small pinholes cannot be disregarded from a safety, efficiency, and operating strategy perspective.

08 HYDROGEN↗

Discovering Reactant Supply Pathways at Electrode/PEM Reaction Interfaces Via a Tailored Interface-Visible Characterization Cell

In situ and micro-scale visualization of electrochemical reactions and multiphase transports on the interface of porous transport electrode (PTE) materials and solid polymer electrolyte (SPE) has been one of the greatest challenges for electrochemical energy conversion devices, such as proton exchange membrane electrolyzer cells (PEMECs), CO 2 reduction electrolyzers, PEM fuel cells, etc. Here, an interface-visible characterization cell (IV-CC) is developed to in situ visualize micro-scaled and rapid electrochemical reactions and transports in PTE/SPE interfaces. Taking the PEMEC of a green hydrogen generator as a study case, the unanticipated local gas blockage, micro water droplets, and their evolution processes are successfully visualized on PTE/PEM interfaces in a practical PEMEC device, indicating the existence of unconventional reactant supply pathways in PEMs. Further comprehensive results reveal that PEM water supplies to reaction interfaces are significantly impacted with current densities. Here these results provide critical insights about the reaction interface optimization and mass transport enhancement in various electrochemical energy conversion devices.

30 DIRECT ENERGY CONVERSION↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Developing novel electrodes with ultralow catalyst loading for high-efficiency hydrogen production in proton exchange membrane electrolyzer cells

Hydrogen plays more crucial roles for decarbonizing the planets and meeting the climate challenges because of its high energy density and zero-emission. It can be produced with proton exchange membrane electrolyzer cells (PEMECs) driven by sustainable and renewable energy resources. Although PEMECs have a number of advantages, including high purity production, quick response, and the ability to operate at high pressure facilitating the gas delivering, their performance and cost greatly hinder their commercial-scale applications. To achieve high-efficiency and cost-reduced hydrogen production in PEMECs, we proposed thin engineered liquid/gas diffusion layers (LGDLs) and associated electrodes, i.e., catalyst-coated LGDLs (CCLGDLs), over conventional porous transport layers (PTLs) and catalyst-coated membranes (CCMs). The research approaches in this project are based on material synthesis, in-situ and ex-situ characterizations, component design and treatment, numerical modeling, and cost analysis. The thin and tunable LGDLs (TT-LGDLs) and CCLGDLs were successfully developed with great performance improvement as demonstrated in lab-scale, bench-scale, and system-scale electrolyzer tests. The electrode thickness was reduced from 370 µm to less than 100 µm with simplified fabrication processes. With the catalytically enhanced Ir-based catalyst coating, the as-developed CCLGDLs with a catalyst loading of 0.34 mg Ir /cm 2 achieved a cell performance of 1.77 V at 2 A cm -2 , exhibiting the catalyst mass activity enhanced by >20 times with significant catalyst saving over conventional catalyst cell design. In-situ PEMEC characterizations, including the current distribution mapping and high-speed and multiscale visualizations, were conducted for a deeper understanding of mass transport and electrochemical reactions within an electrolyzer with LGDLs and CCLGDLs. A 2D cell model was developed and validated for the enhanced performance on TT-LGDL through reducing ohmic losses due to nonuniform hydration and water transport. Further, the cost analysis results have shown a path to move beyond equivalency and surpass costs associated with the project baseline. In this project, the design and fabrication of TT-LGDLs and CCLGDLs will contribute to the performance enhancement, manufacturing simplification, and cost reduction for PEMECs and other energy conversion devices, thus shortening their pathways towards commercialization. This project also provides a good foundation for furthering the in-situ reaction interface research.

08 HYDROGEN↗

Estimating the energy requirement for hydrogen production in proton exchange membrane electrolysis cells using rapid operando hydrogen crossover analysis

Hydrogen (H 2 ) crossover in proton exchange membrane water electrolyzers refers to the process by which hydrogen produced at the cathode traverses the membrane and mixes with the oxygen produced at the anode. This phenomenon reduces efficiency and may pose flammability hazards. In this work we present a method for quantifying the H 2 content of the anode exhaust gas using a gas chromatograph that is capable of sampling data every 2 min. Subsequent theory is presented to calculate the crossover flux, overall H 2 efficiency, and H 2 energy requirements. Results the effects of membrane thickness using Nafion TM N117 (178 um) and Nafion TM NR212 (51 um) membranes. Furthermore, it was found that thinner membranes lead to improved VI performance but exhibit higher crossover rates. Despite their increased crossover, leading to decreased hydrogen efficiency, the calculated required energy for NR212 membrane-electrode assemblies (MEAs) was significantly lower than that of N117 MEAs.

08 HYDROGEN↗

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning Catalyst Activation and Utilization Via Controlled Electrode Patterning for Low-Loading and High-Efficiency Water Electrolyzers

An anode electrode concept of thin catalyst-coated liquid/gas diffusion layers (CCLGDLs), by integrating Ir catalysts with Ti thin tunable LGDLs with facile electroplating in proton exchange membrane electrolyzer cells (PEMECs), is proposed. The CCLGDL design with only 0.08 mg Ir cm -2 can achieve comparative cell performances to the conventional commercial electrode design, saving ~97% Ir catalyst and augmenting a catalyst utilization to ~24 times. CCLGDLs with regulated patterns enable insight into how pattern morphology impacts reaction kinetics and catalyst utilization in PEMECs. A specially designed two-sided transparent reaction-visible cell assists the in situ visualization of the PEM/electrode reaction interface for the first time. Oxygen gas is observed accumulating at the reaction interface, limiting the active area and increasing the cell impedances. In this work, it is demonstrated that mass transport in PEMECs can be modified by tuning CCLGDL patterns, thus improving the catalyst activation and utilization. The CCLGDL concept promises a future electrode design strategy with a simplified fabrication process and enhanced catalyst utilization. Furthermore, the CCLGDL concept also shows great potential in being a powerful tool for in situ reaction interface research in PEMECs and other energy conversion devices with solid polymer electrolytes.

08 HYDROGEN↗

Exploring the Impacts of Conditioning on Proton Exchange Membrane Electrolyzers by In Situ Visualization and Electrochemistry Characterization

For a proton exchange membrane electrolyzer cell (PEMEC), conditioning is an essential process to enhance its performance, reproducibility, and economic efficiency. To get more insights into conditioning, a PEMEC with Ir-coated gas diffusion electrode (IrGDE) was investigated by electrochemistry and in situ visualization characterization techniques. The changes of polarization curves, electrochemical impedance spectra (EIS), and bubble dynamics before and after conditioning are analyzed. The polarization curves show that the cell efficiency increased by 9.15% at 0.4 A/cm 2 , and the EIS and Tafel slope results indicate that both the ohmic and activation overpotential losses decrease after conditioning. The visualization of bubble formation unveils that the number of bubble sites increased greatly from 14 to 29 per pore after conditioning, at the same voltage of 1.6 V. Under the same current density of 0.2 A/cm 2 ; the average bubble detachment size decreased obviously from 35 to 25 µm. Furthermore, the electrochemistry and visualization characterization results jointly unveiled the increase of reaction sites and the surface oxidation on the IrGDE during conditioning, which provides more insights into the conditioning and benefits for the future GDE design and optimization.

08 HYDROGEN↗