Search NASA⌕ Search

Engineering topics

Benk, Markus

Publications and source records attributed to Benk, Markus.

Mask-side Hyper-NA EUV imaging on the SHARP microscope

Hyper-NA, the prospective successor to high-numerical aperture (NA) extreme ultraviolet lithography (EUVL) could be inserted soon after 2030. Hyper-NA poses a number of challenges, including reduced depth of focus, amplified mask three-dimensional effects, and increased mask-side angular range. A Hyper-NA capable extreme ultraviolet (EUV) mask-imaging tool can address these challenges and accelerate research and development toward Hyper-NA. The Sharp High-Numerical Aperture Actinic Reticle Review Project (SHARP) EUV mask microscope is supporting mask-side high-NA imaging since 2015. Implementing mask-side Hyper-NA imaging in 2024 enables research and development toward the corresponding nodes of EUVL. Hyper-NA zoneplates at 0.75 4x/8x NA with a 6.7-deg chief ray angle and 0.85 4x/8x NA with a 7.4-deg chief ray angle are added to the SHARP microscope. Imaging at mask-side Hyper-NA is demonstrated. Imaging of 5-nm half-pitch (wafer scale) horizontal lines and spaces is demonstrated using dipole illumination. Imaging of 5-nm half-pitch (wafer scale) vertical lines and spaces is demonstrated using frequency-doubled imaging of 40-nm hp (mask scale) lines and spaces. Normalized image log slope (NILS) and modulation of Hyper-NA image data match closely to simulations for horizontal lines and spaces. A reduction in NILS of 0.3 or less is observed for vertical lines and spaces in the two-beam imaging regime. Through-focus image data are discussed, comparing different dipole sources and mask-side NAs. Mask-side Hyper-NA photomask imaging has been implemented and demonstrated on the SHARP microscope and is now available to users of the instrument.

Benk, Markus↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

Picometer sensitivity metrology for EUV absorber phase

With growing interest in EUV attenuated phase-shift masks due to their superior image quality for applications such as dense contact and pillar arrays, it is becoming critical to model, measure, and monitor the intensity and relative phase of multilayer and absorber reflections. We present a solution based on physical modeling of reflectometry data, which can achieve single picometer phase precision and sensitivity to changes in average film thickness below one atomic monolayer. We measure absorber and multilayer reflectivity to determine thin-film parameters with a multidimensional optimization and then acquire a new measurement of either multilayer or absorber to determine perturbations in surface contamination thickness. While it is difficult to assess the accuracy of the first step, the simplicity of the second step allows us to characterize our sensitivity to changes in contamination thickness. Thus, we apply this analysis using an initial set of measurements and repeated measurements after a period of storage. For the multilayer, the total contamination growth was 1068 pm, which occurred almost exclusively during storage (1085 pm) and decreased very slightly during repeated measurements (-17 pm). For the absorber, the behavior was quite different, with a total growth of 126 pm, which occurred much less during storage (28 pm) and primarily during repeated measurements (98 pm). Ultimately, the change in relative phase (absorber minus multilayer) was -0.86 deg for the multilayer and -1.12 deg for the absorber. We estimate the precision of the surface contamination measurement to be 3σ < 6 pm for measuring thickness and 3σ < 0.2 deg for measuring phase.

36 MATERIALS SCIENCE↗

Amplitude versus phase effects in extreme ultraviolet lithography mask scattering and imaging

It is well established that extreme ultraviolet (EUV) mask multilayer roughness leads to wafer-plane linewidth roughness (LWR) in the lithography process. Analysis and modeling done to date has assumed, however, that the roughness leading to scatter is primarily a phase effect and that the amplitude can be ignored. Under this assumption, simple scattering measurements can be used to characterize the statistical properties of the mask roughness. Here, we explore the implications of this simplifying assumption by modeling the imaging impacts of the roughness amplitude component as a function of the balance between amplitude and phase induced scatter. In addition to model-based analysis, we also use an EUV microscope to compare experimental through focus data to modeling in order to assess the actual amount of amplitude roughness on a typical EUV multilayer mask. The results indicate that amplitude roughness accounts for less than 1% of the total scatter for typical EUV masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability

A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray emission from a pulsed gas discharge in a pseudosparklike electrode geometry

The mechanism of the soft x-ray generation in a pulsed high current discharge is investigated by means of time and space resolved characterization of the extreme ultraviolet emitting regions and discussion of the related electrical circuit parameters. The plasma is ignited in a pseudosparklike electrode geometry. In a discharge of 15 J, stored electrical energy characteristic emission of different gases (oxygen, argon, and nitrogen) is excited in the spectral range from 2 to 5 nm. Special interest is devoted to the 2.88 nm line emission of heliumlike nitrogen ions within the spectral range of the water window to be used for x-ray microscopy. For the nitrogen discharge, an admixture of xenon leads to axial shorter plasma emission as well as to a smaller diameter below 300 {mu}m of the short wavelength emission. Investigation of the xenon related emission in the range of 10-16 nm indicates that radiative cooling is a possible reason for the observed decrease in the radius. Time and spatial resolved images show that the x-ray emission exhibits an axial dynamic in addition to the usual compression occurring in pinch plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗