Search NASA⌕ Search

Engineering topics

Benmore, Chris J

Publications and source records attributed to Benmore, Chris J.

Experimentally Driven Automated Machine-Learned Interatomic Potential for a Refractory Oxide

Understanding the structure and properties of refractory oxides is critical for high temperature applications. In this work, a combined experimental and simulation approach uses an automated closed loop via an active learner, which is initialized by x-ray and neutron diffraction measurements, and sequentially improves a machine-learning model until the experimentally predetermined phase space is covered. Furthermore, a multiphase potential is generated for a canonical example of the archetypal refractory oxide, HfO 2 , by drawing a minimum number of training configurations from room temperature to the liquid state at similar to 2900 degrees C. The method significantly reduces model development time and human effort.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumentation for Structure Measurements on Highly Non-equilibrium Materials

Containerless techniques (levitation) completely eliminate contact with the sample. This unique sample environment allows deep supercooling of many liquids and avoids contamination of high temperature melts. Recent experiments at the APS high energy beamline 11 ID-C used aerodynamic levitation with laser beam heating and acoustic levitation with cryogenic cooling. By using these two methods, liquids were studied over much of the temperature range from -40 to +2500 C. This paper briefly describes the instrumentation and its use with an -Si area detector that allows fast, in-situ measurements. Use of the instruments is illustrated with examples of measurements on molten oxides and aqueous materials.

Weber, Richard↗

A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure

Diamond anvil cells (DACs) are widely used for the study of materials at high pressure. The typical diamonds used are between 1 and 3 mm thick, while the sample contained within the opposing diamonds is often just a few microns in thickness. Hence, any absorbance or scattering from diamond can cause a significant background or interference when probing a sample in a DAC. By perforating the diamond to within 50-100 {micro}m of the sample, the amount of diamond and the resulting background or interference can be dramatically reduced. The DAC presented in this article is designed to study amorphous materials at high pressure using high-energy x-ray scattering (>60 keV) using laser-perforated diamonds. A small diameter perforation maintains structural integrity and has allowed us to reach pressures >50 GPa, while dramatically decreasing the intensity of the x-ray diffraction background (primarily Compton scattering) when compared to studies using solid diamonds. This cell design allows us for the first time measurement of x-ray scattering from light (low Z) amorphous materials. Here, we present data for two examples using the described DAC with one and two perforated diamond geometries for the high-pressure structural studies of SiO{sub 2} glass and B{sub 2}O{sub 3} glass.

36 MATERIALS SCIENCE↗

Formalism for the determination of structural isotope effects with neutrons

In general the analysis of neutron isotopic substitution experiments in terms of partial structure factors and partial pair distribution functions is based on the assumption that the structure of isotopic variants of a molecule is identical. This assumption is clearly only an approximation especially in the case of hydrogen bonding molecular liquids like liquid water and structural isotope effects have been measured with X-rays for more than 20 years. A analysis method of neutron isotope data is presented that avoids the necessity to assume structural equality and allows the determination of the isotope effect in the hydrogen-hydrogen partial structure factor of liquid water from neutron data. It is shown that a combination of X-ray and neutron scattering measurements allows in principle the determination of the isotope effects on all all partials structure factors of liquid water.

08 HYDROGEN↗

Acoustic levitator for containerless measurements on low temperature liquids

A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops at temperatures from -40 to +40 C. The levitator consisted of: (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) a acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ~ 22 kHz and could produce sound pressure levels up to 160 dB. The force applied by the acoustic field could be modulated using a frequency generator to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

Acoustic levitation↗