Search NASA⌕ Search

Engineering topics

Bennett, J.

Publications and source records attributed to Bennett, J..

At least 73 records · Page 4

Dalitz analysis of $D^0 → K^–π^+η$ decays at Belle

We present the results of the first Dalitz plot analysis of the decay D 0 → K – π + η . The analysis is performed on a data set corresponding to an integrated luminosity of 953 fb – 1 collected by the Belle detector at the asymmetric-energy e + e – KEKB collider. The Dalitz plot is well described by a combination of the six resonant decay channels K ¯ * ( 892 ) 0 η , K – a 0 ( 980 ) + , K – a 2 ( 1320 ) + , K ¯ * ( 1410 ) 0 η , K * ( 1680 ) – π + and K 2 * ( 1980 ) – π + , together with K π and K η S-wave components. The decays K * ( 1680 ) – → K – η and K 2 * ( 1980 ) – → K – η are observed for the first time. We measure ratio of the branching fractions, B ( D 0 → K – π + η ) B ( D 0 → K – π + ) = 0.500 ± 0.002 ( stat ) ± 0.020 ( syst ) ± 0.003 ( B PDG ) . Using the Dalitz fit result, the ratio B ( K * ( 1680 ) → K η ) B ( K * ( 1680 ) → K π ) is measured to be 0.11 ± 0.02 ( stat ) – 0.04 + 0.06 ( syst ) ± 0.04 ( B PDG ) ; this is much lower than the theoretical expectations ( ≈ 1 ) made under the assumption that K * ( 1680 ) is a pure 1 3 D 1 state. The product branching fraction B ( D 0 → [ K 2 * ( 1980 ) – → K – η ] π + ) = ( 2. 2 – 1.9 + 1.7 ) × 10 – 4 is determined. In addition, the π η ' contribution to the a 0 ( 980 ) ± resonance shape is confirmed with 10.1 σ statistical significance using the three-channel Flatté model. We also measure B ( D 0 → K ¯ * ( 892 ) 0 η ) = ( 1.4 1 – 0.12 + 0.13 ) % . This is consistent with, and more precise than, the current world average ( 1.02 ± 0.30 ) % , deviates with a significance of more than 3 σ from the theoretical predictions of (0.51–0.92)%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Azimuthal asymmetries of back-to-back π ± - ( π 0 , η , π ± ) pairs in e + e - annihilation

This work reports the first observation of azimuthal asymmetries around the thrust axis in e + e – annihilation of pairs of back-to-back charged pions in one hemisphere, and π 0 and η mesons in the opposite hemisphere. These results are complemented by a new analysis of pairs of back-to-back charged pions. The π 0 and η asymmetries rise with the relative momentum z of the detected hadrons as well as with the transverse momentum with respect to the thrust axis. These asymmetries are sensitive to the Collins fragmentation function $H$ $^{1}_{⊥}$ and provide complementary information to previous measurements with charged pions and kaons in the final state. In particular, the η final states will provide additional information on the flavor structure of $H$ $^{1}_{⊥}$. This is the first measurement of the explicit transverse-momentum dependence of the Collins fragmentation function from Belle data. It uses a dataset of 980.4 fb –1 collected by the Belle experiment at or near a center- of-mass energy of 10.58 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the CKM angle Φ 3 with $B^±→ D({K}_{\mathrm{S}}^0π^+π^–π^0)K^±$ decays

We present the first model-independent measurement of the CKM unitarity triangle angle Φ 3 using B ± → D ( \( {K}_{\mathrm{S}}^0 \) π + π – π 0 ) K ± decays, where D indicates either a D 0 or \( \overline{D} \) 0 meson. Measurements of the strong-phase difference of the D → \( {K}_{\mathrm{S}}^0 \) π + π – π 0 amplitude obtained from CLEO-c data are used as input. This analysis is based on the full Belle data set of $772 × 10^6 B$ \( \overline{B} \) events collected at the Υ(4 S ) resonance. We obtain Φ 3 = ( \( {5.7}_{-8.8}^{+10.2} \) ± 3 . 5 ± 5 . 7) ° and the suppressed amplitude ratio r B = 0 . 323 ± 0 . 147 ± 0 . 023 ± 0 . 051. Here the first uncertainty is statistical, the second is the experimental systematic, and the third is due to the precision of the strong-phase parameters measured from CLEO-c data. The 95% confidence interval on Φ 3 is ( – 29 . 7 , 109 . 5) ° , which is consistent with the current world average.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular focusing ring imaging Cherenkov detector for electron–ion collider experiments

A powerful new electron-ion collider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.

aerogel↗

Choice of tip, signal stability, and practical aspects of piezoresponse-force-microscopy

Piezoresponse force-microscopy (PFM) has become the standard tool to investigate ferroelectrics on the micro- and nanoscale. However, reliability of PFM signals is often problematic and their quantification is challenging and thus not widely applied. Here, we present a study of the reproducibility of PFM signals and of the so-called PFM background signal which has been reported in the literature. We find that PFM signals are generally reproducible to certain extents. The PFM signal difference between 180° domains on periodically poled lithium niobate (PPLN) is taken as the reference signal in a large number of measurements, carried out in a low frequency regime (30-70 kHz). We show that in comparison to Pt coated tips, diamond coated tips exhibit improved signal stability, lower background signal, and less imaging artifacts related to PFM which is reflected in the spread of measurements. This is attributed to the improved mechanical stability of the conductive layer. The average deviation of the mean PFM signal is 38.3%, for a diamond coated tip. Although this deviation is relatively high, it is far better than values from the literature which showed a deviation of approx. 73.1%. Additionally, we find that the average deviation of the background signal from 0 is 11.6% of the PPLN domain contrast. Thus, the background signal needs to be taken into account when quantifying PFM signals and should be subtracted from PFM signals. Those results are important for quantification of PFM signals, since PPLN might be used for this purpose when PFM signals measured on PPLN are related to its macroscopic d{sub 33} coefficient. Finally, the crucial influence of sample polishing on PFM signals is shown and we recommend to use a multistep polishing route with a final step involving 200 nm sized colloidal silica particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reversible piezomagnetoelectric switching in bulk polycrystalline ceramics

Magnetoelectric (ME) coupling in materials offer tremendous advantages in device functionality enabling technologies including advanced electronic memory, combining electronic speed, and efficiency with magnetic robustness. However, low cost polycrystalline ME materials are excluded from most commercial applications, operating only at cryogenic temperatures, impractically large electric/magnetic fields, or with low ME coefficients (1-100 mV/cm Oe). Despite this, the technological potential of single compound ME coupling has continued to drive research into multiferroics over the last two decades. Here we show that by manipulating the large induced atomic strain within the polycrystalline, room temperature multiferroic compound 0.7BiFeO{sub 3}–0.3PbTiO{sub 3}, we can induce a reversible, piezoelectric strain controlled ME effect. Employing an in situ neutron diffraction experiment, we have demonstrated that this piezomagnetoelectric effect manifests with an applied electric field >8 kV/mm at the onset of piezoelectric strain, engineered in to the compound by crystallographic phase mixing. This produces a remarkable intrinsic ME coefficient of 1276 mV/cm Oe, due to a strain driven modification to the oxygen sub-lattice, inducing an increase in magnetic moment per Fe{sup 3+} ion of +0.142 μ{sub B}. This work provides a framework for investigations into strain engineered nanostructures to realize low-cost ME devices designed from the atoms up, as well as contributing to the deeper understanding of single phase ME coupling mechanisms.

36 MATERIALS SCIENCE↗

Accurate Positions for MCG Galaxies

We have measured accurate celestial coordinates for 4741 extragalactic objects, primarily drawn from a list of MCG galaxies with no recently published accurate positions.

MCG↗

Revised sizes and positions for the Mailyan dwarf galaxy catalog

New positions (good to +/- 15 arcsec), revised sizes, and sample cross-identifications are presented for dwarf galaxies discovered and published by Mailyan (1973, Astrofizika, 9, 33). Of the 104 originally cataloged galaxies we were able to recover only 100, despite an extensive search of the red and blue Palomar Observatory Sky Survey (POSS) prints. Over half of the recovered objects were found to correspond to previously cataloged galaxies; few if any of these are dwarf spheriodal galaxies, but rather mostly dwarf irregulars of low surface brightness.

Madore, B. F.↗

High Efficiency Synchronous Rectification in Spacecraft

This paper examines the implementaion of MOSFETs as synchronous rectifiers which results in a substantial improvement in power processing efficency and therefore may result in significant reduction of spacecraft mass and volum for the same payload.

Spacecraft Power↗