Man-Portable Dense Plasma Focus for Neutron Interrogation Application, NLV-009-17, Year 1 of 2
Presentation described project to develop man-portable device for detection of nuclear material using dense plasma focus technology.
Engineering topics
Publications and source records attributed to Bennett, Nichelle.
Presentation described project to develop man-portable device for detection of nuclear material using dense plasma focus technology.
Abstract not provided.
This presentation is going to be bundled with those from all of the participating labs and sent out to DOE and lab participants.
Annual report to DOE
Presentation to JOWOG was uploaded to a classified computer. They now want to release these presentations.
Presentation to JOWOG
Abstract not provided.
A Neutron Diagnosed Subcritical Experiment (NDSE) is designed to quantitatively measure the reactivity of a subcritical (k eff <1.0) plutonium experiment and thereby improve our understanding of primary performance in the absence of underground nuclear testing. Successful implementation of this diagnostic requires a short, intense burst of neutrons be delivered to the fissile assembly at a precise time during a plutonium implosion. Monte Carlo particle transport simulations of representative subcritical experiments have been performed to establish the pulse shape, flux, and timing requirements for the NDSE neutron source. Additional requirements have also been established for detector sensitivity, acceptable background levels, and total diagnostic reliability.
Exhibit describes an optical streaked spectroscopy system that was developed to evaluate the spectral emission of the run-down, run-in, and pinch phases on the Gemini Dense Plasma Focus. Time-resolved emission spectra were captured for Hydrogen, Deuterium, Krypton, and Argon gases from these phases.
Abstract not provided.
Experiments are being performed on the Self-Magnetic Pinch (SMP) electron beam diode on the RITS-6 accelerator at Sandia National Laboratories. This diode produces a tightly focused electron beam (< 3mm diameter) which is incident on a high atomic number bremsstrahlung x-ray converter. Typical diode parameters are 120 kA, 7 MeV, and 70ns current pulse, giving a ~45ns x-ray pulse. Plasmas from contaminants on the electrode surfaces propagate into the A-K vacuum gap, affecting the impedance, x-ray spectrum, and pulse width. These plasmas are measured using diagnostics, which include: spectroscopy, optical imaging, and photon detection; to obtain velocity, density, and temperature information. These parameters are measured both spatially, using multi-fiber arrays, and temporally, using streak cameras and avalanche photodiodes. Plasma densities and temperatures are determined from detailed, time-dependent, collisional-radiative (CT) and radiation transport (RT) models, which include Stark broadening of the hydrogen-alpha transition line and carbon ion line ratios. These results are combined with hybrid PIC/fluid simulations to model the plasma’s overall behavior. Densities of up to 10^19 cm-3 have been measured on the electrode surfaces, decreasing by several orders of magnitude both radially and axially across the vacuum gap. Electrode plasma expansion velocities of up to 10 cm/microsecond correlate well with the decreasing impedance profile (~0.5 Ohms/ns) observed during the pulse.
Presentation on project to improve dense plasma focus (DPF) modeling capability for DFP device being developed as a high-fluence neutron source for use in Neutron Diagnosed Subcritical Experiments.
Abstract not provided.
Abstract not provided.
In this study, the self-magnetic-pinch diode is being developed as an intense electron beam source for pulsed-power-driven x-ray radiography. The basic operation of this diode has long been understood in the context of pinched diodes, including the dynamic effect that the diode impedance decreases during the pulse due to electrode plasma formation and expansion. Experiments being conducted at Sandia National Laboratories' RITS-6 accelerator are helping to characterize these plasmas using time-resolved and time-integrated camera systems in the x-ray and visible. These diagnostics are analyzed in conjunction with particle-in-cell simulations of anode plasma formation and evolution. The results confirm the long-standing theory of critical-current operation with the addition of a time-dependent anode-cathode gap length. The results may suggest that anomalous impedance collapse is driven by increased plasma radial drift, leading to larger-than-average ion v r × B θ acceleration into the gap.
A series of simulations and experiments to resolve questions about the operation of arrays of closely spaced small aspect ratio rod pinches has been performed. Design and post-shot analysis of the experimental results are supported by 3D particle-in-cell simulations. Both simulations and experiments support these conclusions. Penetration of current to the interior of the array appears to be efficient, as the current on the center rods is essentially equal to the current on the outer rods. Current loss in the feed due to the formation of magnetic nulls was avoided in these experiments by design of the feed surface of the cathode and control of the gap to keep the electric fields on the cathode below the emission threshold. Some asymmetry in the electron flow to the rod was observed, but the flow appeared to symmetrize as it reached the end of the rod. Interaction between the rod pinches can be controlled to allow the stable and consistent operation of arrays of rod pinches.
Explore the source record for details and available documents.