Search NASA⌕ Search

Engineering topics

Benton, E. R.

Publications and source records attributed to Benton, E. R..

At least 37 records · Page 2

Linear Energy Transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLD's), plastic nuclear track detectors (PNTD's), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the COSMOS 1887 mission.

Parnell, T. A.↗

Cosmic ray LET spectra and doses on board Cosmos-2044 biosatellite

Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the Linear Energy Transfer (LET) spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (approximately 20 g cm (exp -2) shielding) and outside (1 g cm(exp -2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d (exp -1), respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d(exp -1). The effects of the flight parameters on the total fluence of, and on the dose from the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.

Watts, J. W., Jr.↗

Cosmic ray particles with different LET values under various thicknesses of shielding in low altitude orbits: Calculations and Cosmos-2044 measurements

Fluxes of cosmic ray particles with different LET values were measured on board the COSMOS-2044 biosatellite under various thicknesses of shielding by stacks of CR-39 and nitrocellulose plastic nuclear track detectors (mounted outside the satellite). The component composition of the particles detected under shieldings of 0.1-2.5 g cm(exp -2) is verified by comparing experimental data with the results of model simulations of the fluxes of galactic cosmic ray particles and of radiation belt protons.

Benton, E. V.↗

Genetic and molecular dosimetry of HZE radiation (US-1 RADIAT)

In order to estimate radiation exposure in space, experiments were conducted during the 1st International Microgravity Laboratory (IML-1) mission in order to isolate genetic changes in animal cells caused by cosmic rays. The space measurements were evaluated against results from synthetic cosmic rays produced by particle accelerators on the ground. The biological material used was the tiny soil nematode, Caenorhabditis elegans. The measurements were made by thermoluminescent detectors and plastic nuclear track detectors. The development and the chromosome mechanics in microgravity were studied, and the mutagenesis induced by radiation exposure was analyzed. The results showed that there are no obvious differences in the development, behavior and chromosome mechanics, as a function of gravity unloading (reproduction, self-fertilization and mating of males with hermaphrodites, gross anatomy, symmetry and gametogenesis, pairing, disjoining and recombination of chromosomes). A variety of mutants were isolated, and it was noted that mutants isolated from regions of identified high particles were more severely affected than those isolated by random screening. Linear energy transfer particles seem to favor large scale genetic lesions.

Nelson, Gregory A.↗

Absorbed dose and LET spectra measurements on LDEF

Total absorbed doses measured with TLD's, linear energy transfer (LET) spectra measured with plastic track detectors, and low energy neutrons measured on LDEF have been compared with model calculations. The total absorbed doses measured in TLD's were higher than predicted in the calculations of Armstrong et al. and differ from the calculations of Atwell et al. LDEF LET spectra are dependent on detector orientation, shielding and experiment location. These factors need to be taken into account when modeling the LDEF LET spectra. LET spectra measured with plastic nuclear track detectors (PNTD's) also deviate significantly from calculations especially for high LET particles (LET(sub infinity) H2O greater than 100keV/micron). Modeling efforts to date do not include the contribution of proton induced secondaries. Analysis of polycarbonate PNTD's from the West-side of LDEF has revealed a very high fluence of tracks (greater than 1 x 10(exp 7) tracks/cm(exp 2) under 2 gm/cm(exp 2) shielding). Fluence drops off rapidly as shielding depth increases. Tracks only form in the region of the detector closest to the surface, not in the bulk of the detector. To date no adequate explanation for this observation has been found. We plan to measure range distribution of very high LET (LET (sub infinity) H2O greater than 500 keV/micron) secondary particles produced in silicon wafer by high energy primary cosmic ray particles. Refinements of experimental techniques and model calculations are being carried out in order to understand existing discrepancies between experimental measurements and calculations.

Benton, E. V.↗

Measurement of trapped proton fluences in main stack of P0006 experiment

We have measured directional distribution and Eastward directed mission fluence of trapped protons at two different energies with plastic nuclear track detectors (CR-39 with DOP) in the main stack of the P0006 experiment on LDEF. Results show arriving directions of trapped protons have very high anisotropy with most protons arriving from the West direction. Selecting these particles we have determined the mission fluence of Eastward directed trapped protons. We found experimental fluences are slightly higher than results of the model calculations of Armstrong and Colborn.

Nefedov, N.↗

Contribution of proton-induced short range secondaries to the LET spectra on LDEF

The contribution to the LET (linear energy transfer) spectrum from proton-induced short range secondaries was investigated by making measurements of total track density and LET spectra in CR-39 Plastic Nuclear Track Detectors (PNTD's) at varying shielding depths in the A0015 West-side stack. Proton-induced short range secondaries were found to make a significant contribution to the LET spectra, especially in the region above 100 keV/micron. At present, calculational models do not include this component. Total track density was measured at five shielding depths and was seen to increase as a function of shielding. LET spectra were measured under two shielding depths (2.6 and 9.2 g/cm(exp 2)) and stayed fairly constant as a function of shielding. Prerecovery estimates of LET spectra dropped off rapidly in the 100-300 keV/micron region, while the measured LET spectra extended to higher LET's. Track density and LET spectra measurements of secondaries were made in a CR-39 PNTD stack exposed to 154 MeV accelerator protons. Similarities in LET spectra measured in the A0015 experiment and in the 154 MeV accelerator proton stack demonstrate that a useful first step in modeling the contribution to the LET spectra of secondaries induced by the spectrum of trapped protons would be to model a mono-energetic proton beam being transported through a one-dimensional geometry.

Benton, E. R.↗

Radiation effects in nematodes: Results from IML-1 experiments

The nematode Caenorhabditis elegans was exposed to natural space radiation using the ESA biorack facility aboard Spacelab on International Microgravity Laboratory 1, STS-42. For the major experimental objective dormant animals were suspended in buffer or on agar or immobilized next to CR-39 plastic nuclear track detectors to correlate fluence of HZE particles with genetic events. This configuration was used to isolate mutations in a set of 350 essential genes as well as in the unc-22 structural gene. From flight samples 13 mutants in the unc-22 gene were isolated along with 53 lethal mutations from autosomal regions balanced by a translocation eT1(III;V). Preliminary analysis suggests that mutants from worms correlated with specific cosmic ray tracks may have a higher proportion of rearrangements than those isolated from tube cultures on a randomly sampled basis. Flight sample mutation rate was approximately 8-fold higher than ground controls which exhibited laboratory spontaneous frequencies.

Nelson, G. A.↗

Experiment K-7-41: Radiation Experiments on Cosmos 2044

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 degrees and altitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq. cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10-4 and 3.05 x 10(exp -4) cm(exp -2).s(exp -1).sr(exp -4) of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(infinity).H2O is greater than or equal to 4 keV/micro-m. Neutron measurements yielded 0.018 mremld in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra have been compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 degrees) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCR's, and higher LET particles, in the heavy particle fluxes.

Benton, E. V.↗

Nematode radiobiology and development in space. Results from IML-1

The Radiat experiment was one of 17 investigations which used the ESA Biorack on IML-1 (International Microgravity Laboratory) and it had two objectives. The first objective was to isolate and characterize mutations induced by cosmic rays; the second was to assess the fidelity of development in 0-gravity over two consecutive generations. Two strategies were used to isolate mutations in a set of essential genes or a specific gene and to correlate the genetic events with the passage of charged particles. The results were isolation of 60 lethal mutations whose phenotypes are related to the local pattern of energy deposition. 12 mutations in the unc-22 gene include large deletions as characterized by DNA hybridization studies. Development of nematodes proceeded through two consecutive generations with no obvious defects. Cytoplasmic determinants in embryos, nuclear location and symmetry of cellular anatomy were normal as were Mendelian segregation and recombination of genetic markers.

Nelson, Gregory A.↗

LET spectra of fragmented 600-MeV/A iron beam on aluminum and polyethylene: A preliminary analysis

An iron beam experiment recently conducted at the Lawrence Berkeley Laboratory Bevalac by Benton et al. provides an opportunity for verifying the new Green's function computer code (GRNTRN) and assessing the related nuclear database. The iron beam with 600 MeV/A at extraction traversed a series of beam transport elements, lead foil, and several triggering devices before impacting the target. Of these, only the 2.24 g/sq cm lead foil and target are considered in the transport analysis with an assumed (inferred from calibration) beam energy of 557 MeV/A. A thin layer of CR-39 plastic nuclear track detector (PNTD) was placed in front of the target to monitor the incident flux and a stack of four PNTD's placed behind to measure the linear energy transfer (LET) distribution of the transported beam. Test data are analyzed for three separate targets: 2 g/sq cm aluminum, 5-cm polyethylene, and 8-cm polyethylene. The two-layer GRNTRN results were mapped into the detector response function for comparison with the measured LET spectra. Reasonable agreement is obtained. Future research and analysis can be improved by using a more accurate isotope set or including other important media which significantly alter the beam. The assumption that the fragmentation cross sections are too small for aluminum is inconclusive because the production of fragments by 2 g/sq cm aluminum can be more significantly affected by the fragment contribution originating from the media in front of the target than that currently considered in the analysis.

Shinn, Judy L.↗

HZE beam transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multiple-layered materials. The code is established to operate on the Langley nuclear fragmentation model used in space engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurement. Comparison with 56Fe ion with Pb-Al and Pb-(CH2)x targets shows reasonable agreement.

NASA Discipline Radiation Health↗

LET spectra measurements of charged particles in the P0006 experiment on LDEF

Measurements are under way of the charged particle radiation environment of the Long Duration Exposure Facility (LDEF) satellite using stacks of plastic nuclear track detectors (PNTD's) placed in different locations of the satellite. In the initial work the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTD's located on the west side of the satellite (Experiment P0006). Primary and secondary stopping heavy ions were measured separately from the more energetic particles. Both trapped and galactic cosmic ray (GCR) particles are included, with the latter component being dominated by relativistic iron particles. The results from the P0006 experiment will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed investigation of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEU's) in microelectronics and, especially, more accurate assessment of the risk - contributed by different components of the radiation field (GCR's, trapped protons, secondaries and heavy recoils, etc.) - to the health and safety of crew members.

Benton, E. V.↗

Light-heavy ion measurements in CR-39 located on the Earth side of LDEF

The azimuthal angle distribution and the charge and energy spectra of selected light-heavy (5 less than or equal to Z less than or equal to 8) stopping particles were measured in a single layer of CR-39 plastic nuclear track detector (PNTD) from the stack of the A0015 experiment located on the Earth-end of the LDEF satellite. The directional incidence of the trapped protons is studied by comparing the azimuthal angle distribution of selected recoils, obtained in the LDEF detectors, to that obtained through calibrations of PNTD's with exposures performed with 200 MeV proton beams from different directions.

Csige, I.↗

Radiation Effects on Nematodes: Results from IML-1 Esperiments

The nematode Caenorhabditis elegans was exposed to natural space radiation using the ESA Biorack facility aboard Spacelab on International Microgravity Laboratory 1, STS-42. For the major experimental objective dormant animals were suspended in buffer or on agar or immobilized next to CR-39 plactic nuclear track detectors to correlate fluence of HZE particles with genetic events.

structural gene mutants unc-22 gene worms cosmic r↗

Genetic and Molecular Dosimetry of Hze Radiation

One of the unavoidable risks of spaceflight is exposure to the complex space radiation enviroment which can result in a 50-fold increase in exposure relative to like at the surface of the earth.

electromagnetic radiation HZE particles radiation ↗

Charge, energy, and LET spectra measurements of charged particles in P0006 experiment of LDEF

Measurements are under way of the charged particle radiation environment of the LDEF satellite using stacks of plastic nuclear track detectors (PNTDs) placed in different locations of the satellite. In the initial work, the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTDs located on the west end of the satellite. Primary and secondary stopping heavy ions as well as relativistic galactic cosmic rays (mostly iron particles) were measured separately. The results will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed study of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEUs) in microelectronics and, especially, more accurate assessment of the risk, contributed by the different components of the radiation field to the health and safety of crew members.

Benton, E. V.↗

Radiation exposure of LDEF: Initial results

Initial results from LDEF include radiation detector measurements from four experiments, P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also on the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose ratio dependence of a factor approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly. On the trailing edge of the orbiter a range of doses from 6.64 to 2.91 Gy were measured under Al equivalent shielding of 0.42 to 1.11 g/sq cm. A second set of detectors near this location yielded doses of 6.48 to 2.66 Gy under Al equivalent shielding of 0.48 to 15.4 g/sq cm. On the leading edge, doses of 2.58 to 2.10 Gy were found under Al equivalent shielding of 1.37 to 2.90 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses and dose equivalents, for LET in H2O greater than or = 8 keV/micron, were measured with plastic nuclear track detectors (PNTDs) located in two experiments. Also preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗