Search NASA⌕ Search

Engineering topics

Berg, J

Publications and source records attributed to Berg, J.

The BayREN Integrated Commercial Retrofits (BRICR) Project: An Introduction and Preliminary Results

BayREN Integrated Commercial Retrofits (BRICR) is a DOE-funded project which aims to enhance the capacity of energy efficiency programs to recruit participants, develop retrofits, and measure outcomes in small and medium-sized commercial buildings, a sector notoriously hard to reach and expensive to serve, that accounts for 2/3 of US commercial floor space. To address these barriers, BRICR leverages existing incentives, financing, data, and open source software to facilitate two paths for comprehensive improvements: a deep energy retrofit, or serial upgrades integrated into capital improvement and maintenance cycles. BRICR is developing an integrated workflow for iterative energy modeling of commercial buildings for city energy program managers and auditors - starting with mass building-scale simulation based on public records and proceeding through audit, retrofit, and measurement and verification stages. BRICR builds on existing tools including LBNL’s CBES, NREL’s OpenStudio, PNNL’s Audit Template, and DOE’s BuildingSync and SEED PlatformTM. At each stage, BRICR uses available information to inform simulations (starting with public records but iteratively augmented with observations from energy program staff) to improve the quality of the models that inform decision making. This paper presents initial results from energy models of 1699 office and retail buildings in San Francisco. Building stock data from public records were translated to create a BuildingSync file for each building which was stored in SEED. Each BuildingSync file was then translated to multiple OpenStudio Workflow files for EnergyPlus simulation to estimate energy savings of energy conservation measures (ECM). Energy savings predictions for each ECM were written back to an updated BuildingSync file for each building and re-uploaded to SEED. The distribution of baseline energy simulations was calibrated against the publicly disclosed distribution of energy benchmarking data to increase confidence in results.

Piette, M↗

Toward laser ablation Accelerator Mass Spectrometry of actinides

A project to measure neutron capture cross sections of a number of actinides in a reactor environment by Accelerator Mass Spectrometry (AMS) at the ATLAS facility of Argonne National Laboratory is underway. This project will require the precise and accurate measurement of produced actinide isotopes in many (>30) samples irradiated in the Advanced Test Reactor at Idaho National Laboratory with neutron fluxes having different energy distributions. The AMS technique at ATLAS is based on production of highlycharged positive ions in an electron cyclotron resonance (ECR) ion source followed by acceleration in the ATLAS linac and mass-to-charge (m/q) measurement at the focus of the Fragment Mass Analyzer. Laser ablation was selected as the method of feeding the actinide material into the ion source because we expect it will have higher efficiency and lower chamber contamination than either the oven or sputtering techniques, because of a much narrower angular distribution of emitted material. In addition, a new multi-sample holder/changer to allow quick change between samples and a computer-controlled routine allowing fast tuning of the accelerator for different beams, are being developed. An initial test run studying backgrounds, detector response, and accelerator scaling repeatability was conducted in December 2010. The project design, schedule, and results of the initial test run to study backgrounds are discussed.

99 GENERAL AND MISCELLANEOUS↗

Working Group 7 Summary

The primary subject of working group 7 at the 2012 Advanced Accelerator Concepts Workshop was muon accelerators for a muon collider or neutrino factory. Additionally, this working group included topics that did not fit well into other working groups. Two subjects were discussed by more than one speaker: lattices to create a perfectly integrable nonlinear lattice, and a Penning trap to create antihydrogen.

43 PARTICLE ACCELERATORS↗

The EMMA Accelerator, a Diagnostic Systems Overview

The 'EMMA' Non-Scaling Fixed Field Alternating Gradient (ns-FFAG) international project is currently being commissioned at Daresbury Laboratory, UK. This accelerator has been equipped with a number of diagnostic systems to facilitate this. These systems include a novel time-domain-multiplexing BPM system, moveable screen systems, a time-of-flight instrument, Faraday cups, and injection/extraction tomography sections to analyze the single bunch beams. An upgrade still to implement includes the installation of wall current monitors. This paper gives an overview of these systems and shows some data and results from the diagnostics that have contributed to the successful demonstration of a serpentine acceleration by this novel accelerator.

43 PARTICLE ACCELERATORS↗

6D mu (+/-) cooling using a solenoid-dipole ring cooler for a muon collider

Six dimensional cooling of large emittance {mu}{sup +} and {mu}{sup -} beams is required in order to obtain the desired luminosity for a muon collider. We propose to use a ring cooler that employs both dipoles and solenoids with the additional requirement that the arcs of the ring be achromatic. We describe the lattice and the beam dynamics of the proposed ring, and demonstrate that the lattice gives substantial cooling in all 6 phase space dimensions.

43 PARTICLE ACCELERATORS↗

Upgrading EMMA to Use Low-frequency RF Cavities

EMMA is an experiment to study beam dynamics in fixed field alternating gradient accelerators (FFAGs). It accelerates the beam in about 10 turns using 1.3 GHz cavities in a mode like that used for muon accelerators. Many applications of FFAGs prefer to have slower acceleration, typically thousands of turns. To do so in EMMA would require the RF system to be replaced with a low-frequency, high-gradient system. This paper describes the motivation for studying slow acceleration in EMMA and the required parameters for an RF system to do that. It then describes the technology needed for the RF system.

43 PARTICLE ACCELERATORS↗

EMMA--The world's first non-scaling FFAG

Due to the combination of fixed magnetic field operation with strong focusing, non-scaling FFAGs have a significant potential for future particle accelerator applications. However, this technology has a number of unique features, which must be fully studied before this potential can be realised. To do this, a proof-of-principle non-scaling FFAG, called EMMA - Electron Model for Many Applications - has been constructed at the STFC Daresbury Laboratory in the UK. It has been designed by an international collaboration of accelerator scientists and engineers. It will demonstrate the principle of non-scaling FFAGs and be used to study the features of this type of accelerator in detail.

43 PARTICLE ACCELERATORS↗

Feasibility of Injection/Extraction Systems for Muon FFAG Rings in the Neutrino Factory

Non-scaling FFAG rings have been proposed for muon acceleration in a neutrino factory. In order to achieve small orbit excursion and small time of flight variation, lattices with a very compact cell structure and short straight sections are required. The resulting geometry places very challenging constraints on the injection/extraction systems. The feasibility of injection/extraction is discussed and various implementations focusing on minimization of kicker/septum strength are presented. The injection and extraction systems in the nonscaling FFAG for muon acceleration in a neutrino factory were studied in the ring based on FODO lattice. The vertical direction was found to be preferential for both injection and extraction, which allows for lower kicker strengths and facilitates the distribution of kickers due to a lower phase advance per cell in comparison with the horizontal plane. It is possible to design mirror-symmetric schemes in which the kickers can be reused for both signs of muons. The disadvantage of these solutions is a need for special magnets with large aperture in the injection/extraction region due to the large kicked beam oscillations. The strengths of the required kickers are still very challenging and the fields in the septum magnets dictates the need for a superconducting design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of External Magnetic Fields on the Operation of RF Cavities

Recent experiments have shown severe surface damage and a reduction of the maximum accelerating gradient for an rf cavity that is operating under external magnetic fields. This implies that serious problems may occur in lattices where rf cavities and external magnetic fields coexist, such as those of the proposed neutrino factory and muon collider. Although existing data suggest that this magnetic field dependent breakdown is associated with the emission of electrons from locally enhanced field regions on the cavity surface, the mechanism that drives this effect is not yet well understood. Here, we show that such field emitted electrons are accelerated by the cavity and focused by the magnetic field to the other side of the cavity where they heat its surface. We show that if the magnetic field is strong, significant surface deformation can occur that eventually could limit the accelerating gradient of the cavity. Results of our model are compared to the existing experimental data from an 805 MHz cavity. The geometry of the pillbox cavity in our case is more complicated, and the analysis depends on the electron energies, focused dimensions, and angle of impact, but damage may reasonably be expected with similar cyclical heating above 40 C. However, it is not yet known what the mechanism is for such surface damage to cause a cavity to breakdown. One possibility is that if electrons are focused on a location with a high surface gradient, then the local damage will generate new asperities with higher FN enhancement factors, thus initiating breakdown. While our preliminary analysis offers some quantification on the effects of the magnetic fields on the cavity's operation, other theoretical issues were not addressed. For instance, emission from secondary electrons was disregarded, the asperity was placed on axis, the magnetic field was assumed as uniform, the thermal-diffusion calculation ignored the shape of the rise time, and adopted an approximate calculation. On the theoretical level, it will be interesting to pursue additional simulations exploring these effects in detail. Experimentally, there is a clear need for more well-designed experiments to study, systematically, the effect of external fields on the cavity's operation.

43 PARTICLE ACCELERATORS↗