June 2019 Depleted Uranium Irradiation

Three different irradiations were performed at the Annular Core Research Reactor (ACRR) at Sandia National laboratory on June 4-6, 2019. Each target assembly included two or three depleted uranium targets, as well as a bismuth target and dosimetry packets. In July 2019, the target assemblies were received at TA-48 RC-1, unpackaged, and radiochemical analyses were performed. The analyses included autoradiography and gamma counting of the whole depleted uranium targets, gamma counting of the activation foils, and dissolution of six of the depleted uranium targets, followed by separated radiochemical analysis for a suite of fission products. This report describes the details of the radiochemical analysis and provides final results for the fission and activation product concentrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Final Results for 99 Mo, 111 Ag, 147 Nd, 140 Ba

Seven depleted uranium targets were irradiated at the ACRR reactor in three different irradiations occurring on June 4th, 5th, and 6th, 2019. The targets were received at LANL on July 10, 2019, unpackaged, and analyzed by autoradiography and gamma-ray spectrometry. Table 1 shows a chart of the Target ID, target mass, time the irradiation occurred, and the corresponding LANL sample ID. Six of the targets were dissolved and chemically separated radiochemical analyses were performed for a suite of radionuclides on four of the targets. The final results of the radiochemical separation and analysis of 99 Mo, 111 Ag, 147 Nd and 140 Ba for depleted U samples 4416-01, 4417-01, 4418-01 and 4418-03 are presented in Table 2. Associated errors represent 1σ uncertainty.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improved debris characterization LA09-IDC-NDD04

In July 2009, LANL's C-NR installed an EDAX OrbisPC Elemental Analysis Tool, a {mu}-X-ray Fluorescence ({mu}-XRF) instrument. This instrument was purchased as an advanced screening tool for an accelerated actinide assay scheme. The purpose of the present work was to establish the instrument's ultimate performance capabilities and to determine what type of samples were amenable to fluorescence study. Using inkjet deposited U standards, U (and similarly Pu) detection limits were found to be {approx}7 pg, with a factor of 2.48 uncertainty (standard limited). Practical limits based on a 1 hour survey of these standards were approximately 50 pg U(Pu). Several crude contaminated soil samples were surveyed and Pu- and U-containing particles ranging from 60 {micro}m to 0.5 mm (maximum dimension) were located. Samples from NTS glass and Mexican ore bodies were also examined. The glasses from NTS, which do not have locally high actinide concentrations (as seen in the particles containing percent level actinide concentrations) but on the bulk scale are quite enriched in actinides, were not amenable to {mu}-XRF assay. Ore samples contained reasonably homogeneous distributions of U but had on average percent U concentrations were amenable to {mu}-XRF assay.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗