Search NASA⌕ Search

Engineering topics

Berrios, William M.

Publications and source records attributed to Berrios, William M..

A generalized approach to the thermal analysis of the Long Duration Exposure Facility's flight experiments

The generalized method used in the thermal analysis of the LDEF flight experiments is presented. The approach consists of developing a mathematical lumped parameter node representation of the experiment; defining the source and sink temperature boundary conditions; calculating the albedo, infrared, and solar orbital heating fluxes; and solving with a finite difference technique. The temperature predictions can be made either on a per orbit basis or for any length of mission time using a daily averaged calculated composite flux. The thermal analysis of the Ultra Heavy Cosmic Ray Experiment (UHCRE-A0178) is presented as an example of this approach.

Sampair, Thomas R.↗

Long duration exposure facility post-flight thermal analysis, part 1

Results of the post-flight thermal analysis of the Long Duration Exposure Facility (LDEF) mission are presented. The LDEF mission thermal analysis was verified by comparing the thermal model results to flight data from the LDEF Thermal Measurements System (THERM). Post-flight calculated temperature uncertainties have been reduced to under +/- 18 F from the pre-flight uncertainties of +/- 40 F. The THERM consisted of eight temperature sensors, a shared tape recorder, a standard LDEF flight battery, and an electronics control box. The temperatures were measured at selected locations on the LDEF structure interior during the first 390 days of flight and recorded for post-flight analysis. After the LDEF retrieval from Space on 12 Jan. 1990, the tape recorder was recovered from the spacecraft and the data reduced for comparison to the LDEF predicted temperatures. The LDEF mission temperatures were calculated prior to the LDEF deployment on 7 Apr. 1980, and updated after the LDEF retrieval with the following actual flight parameter data: including thermal fluxes, spacecraft attitudes, thermal coatings degradation, and contamination effects. All updated data used for the calculation of post-flight temperatures is also presented in this document.

Berrios, William M.↗

Long duration exposure facility post-flight thermal analysis, part 2

Results of the post-flight thermal analysis for the Long Duration Exposure Facility (LDEF) mission are presented. The LDEF mission thermal analysis was verified by comparing the thermal model results to flight data from the LDEF Thermal Measurements System (THERM). Post-flight calculated temperature uncertainties have been reduced to under +/- 18 F from the pre-flight uncertainties of +/- 40 F. The THERM consisted of eight temperature sensors, a shared tape recorder, a standard LDEF flight battery, and an electronics control box. The temperatures were measured at selected locations on the LDEF structure interior during the first 390 days of flight and recorded for post-flight analysis. After the LDEF retrieval from Space on 12 Jan. 1990, the tape recorder was recovered from the spacecraft and the data reduced for comparison to the LDEF predicted temperatures. The LDEF mission temperatures were calculated prior to the LDEF deployment on 7 Apr. 1980, and updated after the LDEF retrieval with the following actual flight parameter data: thermal fluxes, spacecraft attitudes, thermal coatings degradation, and contamination effects. All updated data used for calculation of post-flight temperatures is also presented in this document.

Berrios, William M.↗

Use of the Long Duration Exposure Facility's thermal measurement system for the verification of thermal models

The Long Duration Exposure Facility (LDEF) postflight thermal model predicted temperatures were matched to flight temperature data recorded by the Thermal Measurement System (THERM), LDEF experiment P0003. Flight temperatures, recorded at intervals of approximately 112 minutes for the first 390 days of LDEF's 2105 day mission were compared with predictions using the thermal mathematical model (TMM). This model was unverified prior to flight. The postflight analysis has reduced the thermal model uncertainty at the temperature sensor locations from +/- 40 F to +/- 18 F. The improved temperature predictions will be used by the LDEF's principal investigators to calculate improved flight temperatures experienced by 57 experiments located on 86 trays of the facility.

Berrios, William M.↗

Effects of low Earth orbit environment on the Long Duration Exposure Facility thermal control coatings

One of the benefits of the Long Duration Exposure Facility (LDEF) was the opportunity to study the before and after effects of low earth orbit space environment on the spacecraft thermal control coatings. Since the LDEF's thermal control was totally passive by design, the selection of the external surface absorptivity to emissivity ratio (alpha/epsilon) and the ability for the coating to retain the alpha/epsilon over time was an important consideration in the thermal design of the LDEF. The primary surface coating chosen for the LDEF structure was clear chromic anodized aluminum with an average design alpha/epsilon of 0.32/0.16. External surface absorptivity (alpha) and emissivity (epsilon) were measured on all intercostals, longerons, tray mounting flanges, thermal control panels, and a limited number of experiment surface coatings after the experiment trays were removed from the LDEF structure. All surface alpha/epsilon measurements were made using portable hand held infrared and solar spectrum reflectometers. The absorptivity measurements were taken with a Devices and Services SSR-ER version 5.0 solar spectra reflectometer which has a stated uncertainty of +/- 0.01, and all normal emissivity measurements were made using the Gier Dunkle DB-100 infrared reflectometer also with a stated uncertainty of +/- 0.01. Both instruments were calibrated in the laboratory by LaRC instrumentation personnel before being used in the field at KSC. A combined total of 733 measurements were taken on the anodized aluminum hardware which included the structure (intercostals, longerons, and center ring), earth and space end thermal control panels, and experiment tray mounting flanges. The facility thermal control coatings measured in this survey cover 33 percent of the total exposed LDEF surface area. To correlate low earth orbit environmental effects on the anodized coatings, measurements were taken in both exposed and unexposed surfaces and compared to quality assurance (QA) measurements taken on the new surfaces at the time of hardware fabrication in 1978. The results of investigation are presented.

Sampair, Thomas R.↗

Use of the Long Duration Exposure Facility's thermal measurement system for the verification of thermal models

Results are presented of the comparison between the Long Duration Exposure Facility (LDEF) Thermal Measurements Systems (THERM) recorded temperature data and the predicted values as calculated prior to the LDEF deployment. The postflight thermal model was verified and calculated temperature uncertainties were reduced to under + or - 18 F from the preflight uncertainties of + or - 40 F. The THERM consisted of 8 temperature sensors, a shared tape recorder, a standard LDEF flight battery, and an electronics control box. The temperatures were measured at selected locations on the LDEF structure interior during the first 490 days of flight and recorded for postflight analysis. After the recorder was recovered from space, the tape recorder was recovered and the data reduced for comparison to the LDEF predicted temperatures. By comparing the calculated values to the measured data, a verified thermal model that presents the best agreement with the THERM data was obtained. The THERM experiment provided an economical way of performing a postflight verification of the LDEF Thermal Model by recording a limited number of flight temperatures on typical locations of the LDEF structure.

Berrios, William M.↗

Long duration exposure facility post-flight thermal analysis: Orbital/thermal environment data package

A post flight mission thermal environment for the Long Duration Exposure Facility was created as part of the thermal analysis data reduction effort. The data included herein is the thermal parameter data used in the calculation of boundary temperatures. This boundary temperature data is to be released in the near future for use by the LDEF principal investigators in the final analysis of their particular experiment temperatures. Also included is the flight temperature data as recorded by the LDEF Thermal Measurements System (THERM) for the first 90 days of flight.

Berrios, William M.↗

Long duration exposure facility solar illumination data package

A post flight solar illumination data package was created by the LDEF thermal analysis data group in support of the LDEF science office data group. The data presented was prepared with the Thermal Radiation Analysis System (TRASYS) program. Ground tracking data was used to calculate daily orbital beta angles for the calculation of resultant fluxes. This data package will be useful in calculation of solar illumination fluent for a variety of beta angle orbital conditions encountered during the LDEF mission.

Berrios, William M.↗