Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗