Search NASA⌕ Search

Engineering topics

Bhandari, Pradeep

Publications and source records attributed to Bhandari, Pradeep.

At least 19 records

Design and Analysis of V-Groove Passive Cryogenic Radiators for Space-borne Telescopes & Instruments

V-groove passive radiators are extremely efficient passive designs to thermally isolate a cryogenic telescope or instrument from warm environments in space, like the Sun, Earth, Moon or Spacecrafts. Compared to traditional multi-layer insulation blankets employed for thermal isolation, the V-Groove radiators provide as much as an order of magnitude improvement. The V-Groove design typically constitutes three low emissivity, lightweight and thin aluminized Mylar/Kapton sheets angled from each other by just few degrees. These successively reflect heat from warmer shields to space via their angular openings, thus minimizing heat flow into the cryogenic system. Thermal analysis of these V-Groove radiators is typically performed by sophisticated thermal software that uses hundreds of thousands of rays to simulate radiative heat flow between successive shields via reflections, which can be very time & resource intensive. We have arrived at very simple closed form equations to predict the thermal behavior of these radiators, that includes their radiative heat transfer factors and temperatures as a function of their basic thermo-optical properties and inter-shield angles. These predictions can be done by hand calculators or in spreadsheet tools like MS-Excel. They compare very well to those from sophisticated computer programs. The ease in the use of these simple equations allow for instantaneous predictions of cryogenic temperatures and their trends for design options and trade studies. A case study of this was utilized for the telescope project that is currently being designed for an all sky spectral survey of the universe. This paper will describe the derivations of these equations, their comparison with computer software results and their applicability for current and future cryogenic space telescope and instrument missions

Bhandari, Pradeep↗

Thermal Architecture of A Conceptual Mars Sample Return Lander during Cruise and on Mars

A Pre-Project team is currently studying a conceptual Mars Sample Return (MSR) architecture that would return samples collected by Mars 2020 to Earth. The basic architecture comprises of acquisition of these samples using a sample retrieval lander (SRL), which also would also house the Mars Ascent Vehicle (MAV) and Sample Fetch Rover (SFR). The MAV would put the orbiting sample container (OS) in a Martian orbit, which would then rendezvous with an Earth return orbiter (ERO) and be sent to Earth. This paper focuses on the SRL portion of the potential MSR campaign. The thermal architecture of this mission during cruise to Mars presents several challenges that pertain to the thermal control of the spacecraft and the lander/MAV/rover throughout cruise under varying thermal environments & operating conditions. Additionally, the control of these systems within their allowable operating temperature limits on the Martian surface is very challenging because of the large fluctuations in the environment, operating conditions and limited electrical power and energy availability. This paper will describe the thermal architecture for a potential SRL mission, the key thermal requirements and interfaces.It should be noted that the decision to implement MSR will not be finalized until NASA’s completion of the National Environmental Policy Act (NEPA) process. This document is being made available for information purposes only.

Nicholas, Austin↗

Europa Clipper Passive Thermal Control Valve Test and Analysis

Europa Clipper spacecraft utilizes passive thermal control valves (TCV) in an active thermal control system to maintain spacecraft component temperatures within their allowable limits. The single-phase mechanically pumped fluid loop recovers heat from the electronics and uses it to maintain propulsion system warm. When excess heat is dissipated the mixing valves direct the fluid to the radiator to reject this additional heat. The loop uses two mixing TCVs placed in series to modulate fluid flow and heat rejection rate from the radiator. This paper describes the thermal and hydraulic test results for Europa Clipper engineering model (EM) mixing valves. For the first time two heritage mixing valves previously developed for the Mars Science Laboratory (MSL) were placed in series to modulate flow to the radiator from 0.1% to 95% of full flow between temperature range of 4 oC to 24 oC. Individually, each mixing valve was able to modulate the flow from 2% to 96% of full flow between the temperatures of 4 oC and 24 oC. Pressure drop was measured between 1.5 to 3 psid depending on the temperature of the mixed fluid and the opening fraction of the valves. A methodology was developed, tested, and validated to adjust the setpoints with an accuracy of 0.1 oC. The measured flow splits were corrected for the effects of impedance due to the flow meters used to measure the flow rates. Finally, flow rate to the radiator increased linearly as a function of mixed temperature for individual valves, while it increased parabolically with temperature when two mixing valves were placed in series.

Mastropietro, AJ↗

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler↗

Thermal control technologies for Europa Clipper mission

The Europa Clipper Mission to Europa, a moon of Jupiter, is planned for a launch in 2023. Since Europa is at a large distance (5.6 A.U.) from the Sun, the solar flux is less than 4% of that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Hence, conservation of power for use in thermal control is extremely important. To achieve this goal a mechanically pumped fluid loop heat rejection system (HRS) is utilized to harvest waste heat from the spacecraft components. In addition to this, several thermal control technologies are employed. They include a high performance dual Multi-Layer Insulation (MLI) blanket design to minimize the large majority of heat loss from the spacecraft; two passive thermal control valves in series to greatly reduce the heat loss from the HRS to its radiator; and a low temperature louver to further reduce the loss from the radiator. This paper will describe these technologies, schemes for their implementation, and results of development tests to validate their performance.

Duran, Mark↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database are investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components is used as an example in this study.

Daimaru, Takuro↗

A Dual Multilayer Insulation Blanket Concept to Radically Reduce Heat Loss From Thermally Controlled Spacecraft and Instruments

At large distances from the Sun (e.g. Jupiter/Saturn), the solar flux is less than 4% that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Heat loss through Multi-Layer Insulation (MLI) blankets typically constitutes the vast majority of the total heat loss. Hence, improvements to MLI blankets that reduce heat loss are advantageous to the spacecraft design. The overall effective emittance (ε*) of MLI is usually a range dependent on the number of layers, size of blanket, seams, feedthroughs, layer density and operating temperatures of the heat source and heat sink. A concept has been developed at JPL to reduce the ε* by as much as a factor of two, which produces a corresponding reduction in heat losses. This concept utilizes two MLI blankets physically separated by traditional bumpers or spacers used for micrometeoroid protection. The outer surface of the inner blanket and the inner surface of the outer blanket are low emissivity surfaces to further minimize the total ε* of the overall dual MLI system. Analytical predictions of a dual MLI concept have been made using test data based ε* correlations. A development test has been conducted to validate the dual blanket design’s performance. This paper will describe the dual blanket design concept, schemes for its implementation, and the corresponding test results to validate its performance.

Duran, Mark↗

Europa Clipper Thermal Control Design

This paper details the design developments of the Europa Clipper spacecraft thermal control system and its primary element the Heat Redistribution System (HRS). The Europa Clipper spacecraft will launch in the early 2020s and will have multiple flybys of Jupiter’s icy moon, Europa. The HRS, which utilizes a Mechanically Pumped Fluid Loop (MPFL) to reclaim waste heat from an avionics vault module and redistribute it to the propulsion module and radiator, has become an integral part of the spacecraft architecture both in terms of mechanical configuration and spacecraft operations capability. A walkthrough on the planned implementation of the HRS on the primary spacecraft modules is provided along with a description on thermal control of spacecraft hardware not located on the HRS vault, where thermal isolation and tolerance to extreme thermal environment drives the hardware designs.

Bhandari, Pradeep↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗