Search NASA⌕ Search

Engineering topics

Biegalski, Steven R

Publications and source records attributed to Biegalski, Steven R.

SDAT – Analysis of 131mXe with 133Xe Interference

The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radioxenon production through neutron irradiation of stable xenon gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

ARSA↗

Comparison of Phoswich and ARSA-type detectors for Radioxenon Measurements

The monitoring of atmospheric radioxenon to ensure compliance with the Comprehensive Nuclear Test Ban Treaty has driven the development of improved detectors for measuring xenon, including the development of a phoswich detector. This detector uses only one PMT to detect beta-gamma coincidence, thus greatly reducing the bulk and electronics of the detector in comparison to the ARSA-type detector. In this experiment, 135Xe was produced through neutron activation and a phoswich detector was used to attain spectra from the gas. These results were compared to similar results from an ARSA-type beta-gamma coincidence spectrum. The spectral characteristics and resolution were compared for the coincidence and beta spectra. Using these metrics, the overall performance of the phoswich detector for beta-gamma coincidence of radioxenon was evaluated.

ARSA↗

A software package using a mesh-grid method for simulating HPGe detector efficiencies

Traditional ways of determining the absolute full-energy peak efficiencies of high-purity germanium (HPGe) detectors are often time consuming, cost prohibitive, or not feasible. A software package, KMESS (Kevin's Mesh Efficiency Simulator Software), was developed to assist in predicting these efficiencies. It uses a semiempirical mesh-grid method and works for arbitrary source shapes and counting geometries. The model assumes that any gamma-ray source shape can be treated as a large enough collection of point sources. The code is readily adaptable, has a web-based graphical front-end. and could easily be coupled to a 3D scanner. As will be shown. this software can estimate absolute full-energy peak efficiencies with good accuracy in reasonable computation times. It has applications to the field of gamma-ray spectroscopy because it is a quick and accurate way to assist in performing quantitative analyses using HPGe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗