Search NASA⌕ Search

Engineering topics

Biekert, A.

Publications and source records attributed to Biekert, A..

At least 19 records

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of the HeRALD superfluid helium detector concept

The SPICE/HeRALD collaboration is performing research and development to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid 4 He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and 4 He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical “quantum evaporation” signal from 4 He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype “HeRALD v0.1” detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. Here, a key result of this work is the measurement of the quantum evaporation channel’s gain of 0.15±0.01, which will enable 4 He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5⁢σ, which would be sensitive to dark matter masses down to 220 MeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the scalar WIMP-pion coupling with the first LUX-ZEPLIN data

Weakly interacting massive particles (WIMPs) may interact with a virtual pion that is exchanged between nucleons. This interaction channel is important to consider in models where the spin-independent isoscalar channel is suppressed. Using data from the first science run of the LUX-ZEPLIN dark matter experiment, containing 60 live days of data in a 5.5 tonne fiducial mass of liquid xenon, we report the results on a search for WIMP-pion interactions. We observe no significant excess and set an upper limit of 1.5 × 10$^{−46}$ cm$^{2}$ at a 90% confidence level for a WIMP mass of 33 GeV/c$^{2}$ for this interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New constraints on ultraheavy dark matter from the LZ experiment

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV / c 2 to a few TeV / c 2 . Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9 tonne × yr , to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10 17 GeV / c 2 . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First constraints on WIMP-nucleon effective field theory couplings in an extended energy region from LUX-ZEPLIN

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent nonrelativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keV. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual nonrelativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c 2 . The most stringent limit is set for spin-independent scattering at 36 GeV/c 2 , rejecting cross sections above 9.2×10 –48 cm 2 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

A backing detector for order-keV neutrons

In this work, we have designed and tested a large-area (0.15 m 2 ) neutron detector based on neutron capture on 6Li. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy (<100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$\textit{v}$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of ~25% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of ~ 17 μs. The prototype was characterized using a 252 Cf neutron source and agreement with the simulation was observed within a few percent level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic production of 37 Ar in the context of the LUX-ZEPLIN experiment

We estimate the amount of 37 Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting 37 Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of 37 Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average 37 Ar activity after 10 tons are purified and transported underground is 0.058 − 0.090 𝜇⁢Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic 37 Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of 37 Ar should be considered when planning for future liquid-xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10 -48 cm 2 for a WIMP mass of 40 GeV/c 2 and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The electric field dependence of single electron emission in the PIXeY two-phase xenon detector

Dual phase xenon detectors are widely used in experimental searches for galactic dark matter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. Here, in this paper, we describe single electron backgrounds in 83m Kr calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.

47 OTHER INSTRUMENTATION↗

Projected sensitivity of the LUX-ZEPLIN experiment to the two-neutrino and neutrinoless double $\beta$ decays of $^{134}$Xe

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of 134 Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of 134 Xe, for which xenon detectors enriched in 136 Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7 x 10 24 years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7 x 10 23 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3 x 10 24 years at 90% CL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗