Experimental evidence of thermonuclear neutrons in a modified plasma focus

The PF-1000 plasma focus was modified by adding the cathode disk 3 cm in front of the anode. This modification facilitated the evaluation of neutron energy spectra. Two neutron pulses were distinguishable. As regards the first neutron pulse, it lasted 40 ns during the plasma stagnation and it demonstrated high isotropy of neutron emission. A peak neutron energy detected upstream was 2.46{+-}0.02 MeV. The full width of neutron energy spectra of 90{+-}20 keV enabled to calculate an ion temperature of 1.2 keV. These parameters and a neutron yield of 10{sup 9} corresponded to theoretical predictions for thermonuclear neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by {approx_equal}1 MJ plasma focus

The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of {approx_equal}1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of D-D Reaction at the Plasma Focus Device

The plasma focus device PF-1000 at IPPLM Warsaw with neutron yields of 10{sup 9}-10{sup 11} neutrons per shot is convenient for the determination of the axial neutron energy distribution in the fusion D-D reaction due to the horizontal position of a discharge axis and the distance of scintillation detectors up to 85 m from the neutron source in both axial (downstream and upstream) directions. In this paper the determination of the axial energy component of the fast deuterons producing neutrons is presented for the shot with a relative small neutron yield and nearly isotropic neutron energy distribution and the total energy of fast deuterons producing neutrons is estimated. We calculated, if the dense structure with the length of 2 cm and the density of 2xl0{sup 25} m{sup -3} could be the source of neutrons. We estimated the upper limit of energy of deuterons producing neutrons as 10-20 keV and their total number as 10{sup 18}. The deuterons with energies below 10-20 keV can't produce high number of neutrons due to the small cross-section of D-D reaction but they can be principally confined by magnetic field. We discuss the influence of magnetic field on the motion of deuterons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-Neutron Source Based on Plasma-Focus Device

This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Activation Technique and MCNP Calculations for Measurement of Fast Neutron Spatial Distribution at the MJ Plasma Focus Device

In this paper Plasma-Focus (PF) neutron emission properties have been studied using Monte Carlo calculations for neutron and photon transport. A Thermal Neutron Scaling Factor as a function of angular position of silver activation detectors placed around MJ Plasma Focus (PF-1000) device has been calculated. Detector responses calculated for 2.5 MeV neutrons and neutrons produced by Am-Be calibration source have been obtained .The results have shown the detector response dependence on the kind of calibration neutron source and on local geometrical/structural characteristics of the PF-1000 devices. Thus the proper calibration procedure ought to be performed for correct measurement of neutron yield within Plasma-Focus devices.