Search NASA⌕ Search

Engineering topics

Bier, Milan

Publications and source records attributed to Bier, Milan.

Computer simulation of two electrophoretic columns coupled for isoelectric focusing in simple buffers

Computer simulation is used to analyze a system of two electrophoretic columns coupled by mixing the anolyte of one with the catholyte of the other. A mathematical model is presented which is used to predict the pH gradients formed by monovalent buffers in this system, when the currents in the columns are unequal. In the column with the higher current a pH gradient is created which increases from anode to cathode and is potentially useful for isoelectric focusing. The breadth of this gradient is dependent upon the ratio of the currents. The function of the second column is the compensation of buffer migration which occurs in the first column, thereby maintaining constant electrolyte composition. The effects of buffer pKs and mobilities are evaluated.

Tsai, Amos↗

Rotating apparatus for isoelectric focusing

This disclosure is directed to an isoelectric focusing apparatus, wherein stabilization of the fluid containing the isolated proteins is achieved by carrying out the separation in a rotating cylinder with the separation cavity of the cylinder being segmented by means of filter elements. The filter elements are constituted of a material offering some degree of resistance to fluid convection, but allowing relatively free and unhindered passage of current and transport of proteins. The combined effect of segmentation and rotation has been found to be superior to either segmentation or rotation alone in maintaining the stability of the migrated fractions.

Bier, Milan↗

Isoelectric focusing of dansylated amino acids in immobilized pH gradients

The 21 free amino acids commonly encountered in proteins have been transformed into 'carrier ampholyte' species by reacting their primary amino groups with dansyl chloride. These derivatives can thus be focused in an immobilized pH gradient covering the pH interval 3.1 to 4.1, except for arginine, which still retains a pI of 8.8. Due to their inherent fluorescence, the dansyl derivatives are revealed in UV light, with a sensitivity of the order of 2-4 ng/sq mm. All nearest neighbors are separated except for the following couples: Asn-Gln, Gly-Thr, Val-Ile and Cys-Cys2, with a resolving power, in a Delta(pI) scale, of the order of 0.0018 pH units. Except for a few cases (notably the aromatic amino acids), the order of pI values is well correlated with the pK values of carboxyl groups, suggesting that the latter are not altered by dansylation. From the set of pK(COOH)-pI values of the different amino acids, the pK of the tertiary amino group in the dansyl label has been calculated to be 5.11 + or - 0.06. Knowing the pK of the amino-dansyl and the pI of the excess, free dansyl label (pI = 3.34), a pK of 1.57 is derived for its sulfonic acid group.

Bianchi-Bosisio, Adriana↗

Computer simulation of immobilized pH gradients at acidic and alkaline extremes - A quest for extended pH intervals

Computer simulations of the concentration profiles of simple biprotic ampholytes with Delta pKs 1, 2, and 3, on immobilized pH gradients (IPG) at extreme pH values (pH 3-4 and pH 10-11) show markedly skewed steady-state profiles with increasing kurtosis at higher Delta pK values. Across neutrality, all the peaks are symmetric irrespective of their Delta pK values, but they show very high contribution to the conductivity of the background gel and significant alteration of the local buffering capacity. The problems of skewness, due to the exponential conductivity profiles at low and high pHs, and of gel burning due to a strong electroosmotic flow generated by the net charges in the gel matrix, also at low and high pHs, are solved by incorporating in the IPG gel a strong viscosity gradient. This is generated by a gradient of linear polyacrylamide which is trapped in the gel by the polymerization process.

Mosher, Richard A.↗

An explanation for the plateau phenomenon in isoelectric focusing

Isoelectric focusing of mixtures of simple ampholytes occurs in two phases, an initial rapid separation phase and a second relatively slow stabilizing phase. Transient and steady-state computer simulation data are shown to predict the development of pH plateaus around neutrality during the stabilizing phase of the focusing of such mixtures. This occurs because a nonzero electrophoretic flux is present in a pure zone of focused ampholyte, which is a function of both its isolectric point (pI) and its Delta-pK value. For an ampholyte with a pI greater than 9 or less than 5, this flux causes the development of a significant concentration gradient within its focused zone which is accompanied by a contraction of this zone along the focusing axis. Acidic and basic ampholytes are thereby displayed toward the anode and cathode respectively, creating a pH plateau in the neutral region. Thus, there will be regions of the focusing column, closer to the electrodes and containing more acidic or basic pH values, within which the resolution of samples will reach a maximum and then decrease.

Mosher, Richard A.↗

Scale-up of isoelectric focusing

The paper describes some applications to large scale protein fractionation using a recycling isoelectric focusing apparatus. Separation is achieved in free solution without the use of supporting media. Various alternatives for the formation of the pH gradient are discussed and results of a computer simulation are presented.

Bier, Milan↗

Recycling isotachophoresis - A novel approach to preparative protein fractionation

The concept of automated recycling isotachophoresis (RITP) as a purification methodology is discussed, in addition to a description of the apparatus. In the present automated RITP, the computer system follows the achievement of steady state using arrays of universal and specific sensors, monitors the position of the front edge of the zone structure, activates the counterflow if the leading boundary passes a specified position along the separation axis, or changes the applied current, accordingly. The system demonstrates high resolution, in addition to higher processing rates than are possible in zone electrophoresis or isoelectric focusing.

Sloan, Jeffrey E.↗

The formation of stable pH gradients with weak monovalent buffers for isoelectric focusing in free solution

Two methods which utilize simple buffers for the generation of stable pH gradients (useful for preparative isoelectric focusing) are compared and contrasted. The first employs preformed gradients comprised of two simple buffers in density-stabilized free solution. The second method utilizes neutral membranes to isolate electrolyte reservoirs of constant composition from the separation column. It is shown by computer simulation that steady-state gradients can be formed at any pH range with any number of components in such a system.

Mosher, Richard A.↗