Search NASA⌕ Search

Engineering topics

Bilbao, Aivett

Publications and source records attributed to Bilbao, Aivett.

Introducing Molecular Hypernetworks for Discovery in Multidimensional Metabolomics Data

Orthogonal separations of data from high-resolution mass spectrometry can provide insight into sample composition and address challenges of complete annotation of molecules in untargeted metabolomics. “Molecular networks” (MNs), as used in the Global Natural Products Social Molecular Networking platform, are a prominent strategy for exploring and visualizing molecular relationships and improving annotation. MNs are mathematical graphs showing the relationships between measured multidimensional data features. MNs also show promise for using network science algorithms to automatically identify targets for annotation candidates and to dereplicate features associated with a single molecular identity. Here, this paper introduces “molecular hypernetworks” (MHNs) as more complex MN models able to natively represent multiway relationships among observations. Compared to MNs, MHNs can more parsimoniously represent the inherent complexity present among groups of observations, initially supporting improved exploratory data analysis and visualization. MHNs also promise to increase confidence in annotation propagation, for both human and analytical processing. We first illustrate MHNs with simple examples, and build them from liquid chromatography- and ion mobility spectrometry-separated MS data. We then describe a method to construct MHNs directly from existing MNs as their “clique reconstructions”, demonstrating their utility by comparing examples of previously published graph-based MNs to their respective MHNs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Detection of Primary Biological Aerosol Particles Using Machine Learning and Single-Particle Measurement

Accurately identifying primary biological aerosol particles (PBAPs) using analytical techniques poses inherent challenges due to their resemblance to other atmospheric carbonaceous particles. Here, we present a study of an enhanced method for detecting PBAPs by combining single-particle measurement with advanced supervised machine learning (SML) techniques. We analyzed ambient particles from a variety of environments and lab-generated standards, focusing on chemical composition for traditional rule-based and clustering approaches and incorporating morphological features into the SML approaches, neural networks and XGBoost, for improved accuracy. This study demonstrates that SML methods outperform traditional methods in quantifying PBAPs, achieving significant improvements in precision, recall, F1-score, and accuracy, leading to an increased number of detected PBAPs by at least 19%. The adaptability of the proposed XGBoost-based SML model is showcased in comparison to traditional methods in categorizing PBAPs for blind data sets from different geographical locations. Two field case studies were investigated, over agricultural land and Amazonia rain forest, representing relatively low and high concentrations of PBAPs, respectively, where XGBoost consistently detected up to 3.5 times more PBAPs than traditional methods. Precise detection of PBAPs in the atmosphere could significantly improve the prediction of climatic impacts by them.

42 ENGINEERING↗

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗