Search NASA⌕ Search

Engineering topics

Bingham, Philip

Publications and source records attributed to Bingham, Philip.

Enabling rapid X-ray CT characterisation for additive manufacturing using CAD models and deep learning-based reconstruction

Metal additive manufacturing (AM) offers flexibility and cost-effectiveness for printing complex parts but is limited to few alloys. Qualifying new alloys requires process parameter optimisation to produce consistent, high-quality components. High-resolution X-ray computed tomography (XCT) has not been effective for this task due to artifacts, slow scan speed, and costs. We propose a deep learning-based approach for rapid XCT acquisition and reconstruction of metal AM parts, leveraging computer-aided design models and physics-based simulations of nonlinear interactions between X-ray radiation and metals. This significantly reduces beam hardening and common XCT artifacts. We demonstrate high-throughput characterisation of over a hundred AlCe alloy components, quantifying improvements in characterisation time and quality compared to high-resolution microscopy and pycnometry. Our approach facilitates investigating the impact of process parameters and their geometry dependence in metal AM.

36 MATERIALS SCIENCE↗

Harmonic Signals Dataset

The Harmonic Signals Dataset (HSD) consists of one-dimensional time series data collected from current sensors with a goal of providing data for research and development of Non-Intrusive Load Monitoring (NILM) with high sample rate (800kHz) sensors. NILM seeks to detect and characterize electrical equipment operating within a facility by sensing changes in electrical current on the building power system associated with the equipment. To provide data with a known ground truth, but with the realism of a signal introduced within a building facility, a series of known ground truth signals were injected as voltage into the power system of a building and measurements of the signals at multiple locations across the building power system were made with electrical current sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles

Tri-structural isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using x-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the x-ray beam by the uranium core, leading to severe photon starvation in a substantial fraction of the measurements. Furthermore, the overall acquisition time for a high-resolution CT scan can be very long when using conventional laboratory-based x-ray systems and reconstruction algorithms. Specifically, when analytic methods such as the Feldkamp–Davis–Kress (FDK) algorithm are used for reconstruction, it results in severe streak artifacts and noise in the corresponding 3D volume, which makes subsequent analysis of the particles challenging. In this paper, we develop and apply model-based image reconstruction (MBIR) algorithms to improve the quality of CT reconstructions for TRISO particles to facilitate better characterization. We demonstrate that the proposed MBIR algorithms can significantly suppress artifacts with minimal pre-processing compared to conventional approaches. We also demonstrate that the proposed MBIR approach can obtain high-quality reconstruction compared to the FDK approach even when using a fraction of the typically acquired measurements, thereby enabling dramatically faster measurement times for TRISO particles.

Venkatakrishnan, Singanallur↗

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

Beam Hardening Artifact Reduction in X-Ray CT Reconstruction of 3D Printed Metal Parts Leveraging Deep Learning and CAD Models

Nondestructive evaluation (NDE) of additively manufactured (AM) parts is important for understanding the impacts of various process parameters and qualifying the built part. X-ray computed tomography (XCT) has played a critical role in rapid NDE and characterization of AM parts. However, XCT of metal AM parts can be challenging because of artifacts produced by standard reconstruction algorithms as a result of a confounding effect called “beam hardening.” Beam hardening artifacts complicate the analysis of XCT images and adversely impact the process of detecting defects, such as pores and cracks, which is key to ensuring the quality of the parts being printed. In this work, we propose a novel framework based on using available computer-aided design (CAD) models for parts to be manufactured, accurate XCT simulations, and a deep-neural network to produce high-quality XCT reconstructions from data that are affected by noise and beam hardening. Using extensive experiments with simulated data sets, we demonstrate that our method can significantly improve the reconstruction quality, thereby enabling better detection of defects compared with the state of the art. We also present promising preliminary results of applying the deep networks trained using CAD models to experimental data obtained from XCT of an AM jet-engine turbine blade.

Ziabari, Amir↗

A high-pressure flow through test vessel for neutron imaging and neutron diffraction-based strain measurement of geological materials

Neutron scattering and neutron imaging have emerged as powerful methods for experimentally investigating material deformation and fluid flow in the interior of otherwise inaccessible or opaque structures. This paper describes the design and provides example uses of a pressure cell developed for investigating such behaviors within geological materials. The cell can accommodate cylindrical samples with diameters up to 38.1 mm and lengths up to 154 mm. Additionally, ports in the cell and a pressure isolating sleeve around the sample allow the independent application of confining pressure up to 69 MPa and axial pressure up to 34.5 MPa. Furthermore, two material versions of the cell have been manufactured and used to date. An aluminum version is typically used for temperatures below 40 °C, because of its relative transparency to neutrons, while a titanium version, which is comparatively more neutron attenuating, is used for experiments requiring triaxial pressurization under conditions up to 350 °C. The pressure cells were commissioned at the VULCAN engineering diffractometer at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source, and have since been used at the ORNL high flux isotope reactor CG1-D imaging beamline, National Institute of Standard and Technology (NIST) BT-2, and NIST NG6 imaging beamlines.

47 OTHER INSTRUMENTATION↗

Wavelength-resolved Neutron Tomography for Crystalline Materials

Wavelength-resolved (WR) neutron transmission tomography is an emerging technique to characterize engineering materials. While tomographic reconstruction for amorphous samples is straightforward, it is challenging to reconstruct samples with single-crystal domains because the attenuation of the sample varies as a function of its orientation with respect to the incident beam due to Bragg scattering. In this paper, we present an algorithm that can reconstruct samples with single-crystal domains from WR neutron tomographic measurements. In particular, we use a model-based iterative reconstruction (MBIR) technique that reconstructs the volume by identifying and leaving out the regions of the measurement that are affected by Bragg scatter. We combine the output of the MBIR method with an algorithm that matches the reconstruction to the identified Bragg scatter to reconstruct a feature that corresponds to the local crystallography of the sample being measured. Using simulated data, we demonstrate how our algorithm can reconstruct materials with single-crystal domains, thereby adding a powerful new capability for WR neutron imaging instruments.

Singanallur Vaidyanathan, Venkatakrishnan↗

Coded source neutron imaging at the PULSTAR reactor

A neutron imaging facility is located on beam-tube No.5 of the 1-MW PULSTAR reactor at North Carolina State University. An investigation of high resolution imaging using the coded source imaging technique has been initiated at the facility. Coded imaging uses a mosaic of pinholes to encode an aperture, thus generating an encoded image of the object at the detector. To reconstruct the image data received by the detector, the corresponding decoding patterns are used. The optimized design of coded mask is critical for the performance of this technique and will depend on the characteristics of the imaging beam. In this work, a 34 x 38 uniformly redundant array (URA) coded aperture system is studied for application at the PULSTAR reactor neutron imaging facility. The URA pattern was fabricated on a 500 ?m gadolinium sheet. Simulations and experiments with a pinhole object have been conducted using the Gd URA and the optimized beam line.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Coded Source Neutron Imaging at the North Carolina State University PULSTAR Reactor

A neutron imaging facility is located on beam-tube #5of the 1-MWth PULSTAR reactor at the North Carolina StateUniversity. An investigation has been initiated to explore theapplication of coded imaging techniques at the facility. Codedimaging uses a mosaic of pinholes to encode an aperture, thusgenerating an encoded image of the object at the detector. Toreconstruct the image recorded by the detector, correspondingdecoding patterns are used. The optimized design of coded masksis critical for the performance of this technique and will dependon the characteristics of the imaging beam. In this work, MonteCarlo (MCNP) simulations were utilized to explore the neededmodifications to the PULSTAR thermal neutron beam to supportcoded imaging techniques. In addition, an assessment of codedmask design has been performed. The simulations indicated thata 12 inch single crystal sapphire filter is suited for such anapplication at the PULSTAR beam in terms of maximizing fluxwith good neutron-to-gamma ratio. Computational simulationsdemonstrate the feasibility of correlation reconstruction methodson neutron transmission imaging. A gadolinium aperture withthickness of 500 m was used to construct the mask using a 38 ×34 URA pattern. A test experiment using such a URA design hasbeen conducted and the point spread function of the system hasbeen measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗