Search NASA⌕ Search

Engineering topics

Birge, Noah Watson

Publications and source records attributed to Birge, Noah Watson.

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Fast Neutron Imaging and Tomography at NIF [Slides]

The presentation at the first Prompt Radiation Detection and Imaging Workshop covered fast neutron and tomography work at the National Ignition Facility (NIF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

Gamma Imaging on NIS3

Explore the source record for details and available documents.

Geppert-Kleinrath, Verena↗