Search NASA⌕ Search

Engineering topics

Black, James

Publications and source records attributed to Black, James.

At least 19 records

Design optimization of an additively manufactured prototype recuperator for supercritical CO 2 power cycles

Supercritical CO 2 (sCO 2 ) power cycles are being developed due to their potential for high efficiency and reduced capital cost. It is necessary that these recuperators operate at high pressures and temperatures, up to 30 MPa and 900 K, with effectiveness values > 95% and pressure drops <1% to achieve high cycle efficiencies. Moreover, it is also necessary to have reasonable cost recuperators to control the capital costs of the sCO 2 power cycles. In this study, a Plate Pin-Fin (PPF) heat exchanger has been proposed as an sCO 2 recuperator. This preliminary recuperator design leverages capabilities enabled by additive manufacturing. Although the PPF design has characteristics similar to those of a plate heat exchanger, small diameter and relatively long fins are used to increase surface area, enhance heat transfer, and provide structural support for the partition plates that separate the fluid streams. Existing correlations for heat transfer and pressure drop were adapted for the PPF heat exchanger. These correlations were implemented in a 1D analytical model and used for the optimization of a 5-kW th high temperature recuperator for an indirect sCO 2 cycle by varying the design parameters to minimize the quantity of material required. A 3D conjugate heat transfer numerical simulations were conducted to validate the heat transfer and pressure loss correlations. A steepest descent method was used to minimize heat exchanger mass for a 5-kW prototype recuperator subject to a maximum specified pressure drop. Additionally, the design analysis indicated that an optimum PPF recuperator would be attained for the minimum allowable pin transverse spacing, minimum pin width, minimum pin height and near maximum cell aspect ratio. Moreover, at a low material requirement of 0.216 kg/kW and a pressure drop, which is almost five times lower than the allowable pressure drop design target, the optimized PPF heat exchanger has the high potential to be an alternative to a printed circuit heat exchanger, which is a conservative design basis for the current state-of-the-art sCO 2 recuperators.

42 ENGINEERING↗

Impact on Cycle Efficiency of Small Combined Heat and Power Plants from Increasing Firing Temperature Enabled by Additive Manufacturing of Turbine Blades and Vanes

The results of this study show that a 180°F (100°C) increase in firing temperature can increase the gas turbine efficiency by 1 percentage point without improving cooling effectiveness and add 2 additional percentage points in efficiency by using advanced turbine blades with higher internal cooling efficiency. The engine upgrades evaluated in this study show potential for increasing the CHP cycle efficiency by 3 percentage points while increasing the steam generation rate by 8%.

Uysal, Selcuk Can↗

The Effect of Working Fluid Composition on Heat Transfer in a Direct Supercritical CO2 Power Cycle Recuperator

For pure CO2, the experimental measurements of the heat transfer coefficient in this paper agreed to within 5% of the classical Dittus-Boelter correlation. When nitrogen was added to the CO2 at concentrations from 0–28% nitrogen, these experiments found that the measured Nusselt numbers decreased by 20% below the Dittus-Boelter correlation evaluated with thermophysical properties for the N2/CO2 gas mixture. In general, the McAdams correlation evaluated with mixture properties predicted the friction factor within ±10%.

Searle, Matthew↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines - Conference Paper

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Data set for Conventional Rib Turbulators for SCO2 Turbine Internal Cooling

This data set accompanies NETL Internal Report DOE/NETL-2021/2758. M. Searle, D. Straub, and J. Black, “Conventional Rib Turbulators For SCO2 Turbine Internal Cooling,” National Energy Technology Laboratory, Morgantown, June 28, 2021. The "Configuration" tab details the test configuration geometry and nominal set points. The "Exp point data" tab reports the thermal performance at the midpoint of the Wilson plot. The "Wilson plot data" tab are all Wilson resistance plots reported in the present work.

42 ENGINEERING↗

Conventional Rib Turbulators For SCO 2 Turbine Internal Cooling (Report)

This report documents experimental work in the NETL Heat Exchange and Experimental Testing (HEET) rig. The heat transfer performance of additively manufactured internal cooling features in supercritical CO 2 were characterized. It was demonstrated that the thermal performance factor of conventional angled rib turbulators remains independent of Reynolds number up to 3.1 x 10 5 indicating that these features may be employed to enhance heat transfer in sCO 2 turbine blades and vanes. This augmentation of heat transfer in the internal cooling passages decreases the required turbine coolant and improves the power cycle efficiency.

20 FOSSIL-FUELED POWER PLANTS↗

Impact on Cycle Efficiency of Small CHP Plants from Increasing Firing Temperature Enabled by AM of Turbine Blades

Combined Heat and Power (CHP) systems are gaining popularity because of their potential for high overall thermodynamic efficiency and increased need for distributed power generation. Most CHP systems include a gas turbine for electricity generation and a heat recovery steam generator (HRSG) for steam generation. The steam can be used to power a steam turbine for additional electricity generation or to drive rotating equipment, for space heating, for absorption chillers, etc. A CHP cycle configuration is often driven by the ‘principal’ utility for the facility that it services; steam or electricity. In either case, performance improvements in the gas turbine have the potential to increase the steam and power output from the cycle, which is a direct result of improvements in the gas turbine efficiency and power output. One possible opportunity to improve an existing gas turbine’s performance is to increase the firing temperature with improved turbine cooling and increased compression ratio.<br>In this study, the impact on CHP cycle performance from increasing the turbine firing temperature by 100 °C and improving the turbine blade cooling for a 6-MW scale gas turbine is estimated using an analytical cooled gas turbine model and a steam cycle model. A sensitivity analysis was performed to understand the impact of increasing the internal cooling effectiveness, thermal barrier coating performance and blade material upgrades on gas turbine and CHP cycle efficiency. The impacts of turbine blade cooling improvements were studied for three common CHP cycle configurations identified from the literature. Various definitions for CHP cycle efficiency from the literature are used in the comparisons. The results showed that a 100 °C increase in firing temperature can increase the gas turbine efficiency by 1 percentage point without improving cooling effectiveness and add 2 additional percentage points in efficiency by using advanced turbine blades with higher internal cooling efficiency. Studied engine upgrades showed potential for increasing the CHP cycle efficiency by 3 percentage points while increasing the steam generation rate by 8%.<br>

Uysal, Selcuk Can↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Measuring Heat Transfer Coefficients for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in pin-fin patterned pipes at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (𝑁𝑢) and friction factor. Over Reynolds numbers (Re D ) ranging from 5×104 to 2.5×105 , measured 𝑁𝑢 was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow.

42 ENGINEERING↗