Search NASA⌕ Search

Engineering topics

Blake, T. A.

Publications and source records attributed to Blake, T. A..

Analysis of the rotationally-resolved infrared spectrum of CD 3 79 Br and CD 3 81 Br between 900 and 1400 cm -1

We report the infrared spectrum of CD 3 79 Br and CD 3 81 Br between 900 cm -1 and 1400 cm -1 has been analyzed at high resolution. In this region, two fundamental vibrational states, v 2 = 1 and v 5 = 1, an overtone state, v 3 = 2, and a combination state, v 3 = v 6 = 1, have been analyzed for both isotopologues. As found in other halomethane molecules, strong Coriolis resonances couple the v 2 = 1 state to the v 5 = 1 state, and similar resonances were also used to describe the coupling found between the v 5 = 1 state to the v 3 = 2 state. A new determination of the K-dependent constant A 0 was performed for each isotopologue through the use of perturbation-allowed transitions. The values for A 0 determined from the analysis are 2.6001898(26) and 2.6001905(27) for CD 3 79 Br and CD 3 81 Br, respectively. Ab initio calculations were performed to examine the efficacy of high-level theoretical calculations to accurately predict spectroscopic constants. The ab initio calculations had variable success with the largest errors associated with the prediction of the ΔB rotational constants of the interacting states

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of several high-resolution infrared bands of perdeutero-spiropentane, C5D8

Perdeutero-spiropentane (C5D8) has been synthesized and infrared spectra were taken from 400 to 4000 cm-1 at low sample pressures in a 22 meter multipass cell. The spectral resolution (0.0015 cm-1) reveals thousands of individual rovibrational transitions for several fundamental bands occurring in the spectral region of 500 to 1100 cm-1. C5D8 ground state constants reported in a previous study of a ?15 parallel band at 1054 cm-1 [1] were improved significantly in the present work by adding combination-differences derived from ?16 parallel and ?24 perpendicular band analyses. The larger data set at higher J values also allowed determination of the ground state K? = 2 splitting constant (?2? = 0.76(2) ×10-9 cm-1). For ?16, the band origin is 847.16933(5) cm-1 and changes in upper state rotational constants are ?A = –0.0013411(5) and ?B = –0.0002021(1) (in units of cm-1). Overlapping, and in Fermi resonance with ?16, is a second parallel band which, from Gaussian calculations at the anharmonic level, is assigned as the b2 combination ?8+?12, with band origin of 840.5434(1) and ?A = –0.0003500(7) and ?B = –0.0003502(1) cm-1. For ?24 analogous values are 556.41453(2) and ?A = –0.00032295(9) and ?B = –0.00016782(4) cm-1. The analyses also yields accurate values for the changes in both quartic and sextic centrifugal distortion constants and, for ?24, values for the l-doubling constants q+ and q-. Theoretical calculations of the rovibrational parameters aided in the analysis and the numerical values are in good agreement with experimental results.

Nibler, Joseph W.↗

Optimal design of composite hip implants using NASA technology

Using an adaptation of NASA software, we have investigated the use of numerical optimization techniques for the shape and material optimization of fiber composite hip implants. The original NASA inhouse codes, were originally developed for the optimization of aerospace structures. The adapted code, which was called OPORIM, couples numerical optimization algorithms with finite element analysis and composite laminate theory to perform design optimization using both shape and material design variables. The external and internal geometry of the implant and the surrounding bone is described with quintic spline curves. This geometric representation is then used to create an equivalent 2-D finite element model of the structure. Using laminate theory and the 3-D geometric information, equivalent stiffnesses are generated for each element of the 2-D finite element model, so that the 3-D stiffness of the structure can be approximated. The geometric information to construct the model of the femur was obtained from a CT scan. A variety of test cases were examined, incorporating several implant constructions and design variable sets. Typically the code was able to produce optimized shape and/or material parameters which substantially reduced stress concentrations in the bone adjacent of the implant. The results indicate that this technology can provide meaningful insight into the design of fiber composite hip implants.

Blake, T. A.↗

Numerical optimization of composite hip endoprostheses under different loading conditions

The optimization of composite hip implants was investigated. Emphasis was placed on the effect of shape and material tailoring of the implant to improve the implant-bone interaction. A variety of loading conditions were investigated to better understand the relationship between loading and optimization outcome. Comparisons of the initial and optimal models with more complex 3D finite element models were performed. The results indicate that design improvements made using this method result in similar improvements in the 3D models. Although the optimization outcomes were significantly affected by the choice of loading conditions, certain trends were observed that were independent of the applied loading.

Blake, T. A.↗