Search NASA⌕ Search

Engineering topics

Blaskiewicz, M.

Publications and source records attributed to Blaskiewicz, M..

117 records · Page 7

The BBSOLVE User's Manual (V.1.0)

The Fortran program BBSOLVE numerically solves the Balbekov/Burov equation for single bunch transverse instability. It may be used for any particle type. Forces from space charge, resistive wall and multiple resonators are included. This note describes the algorithms and their implementation.

43 PARTICLE ACCELERATORS↗

Longitudinal matching without $γ_t$ quads

The Yellow e-lens lattice requires a different working point (29.68/30.69 instead of 28.68/29.69) to provide the correct betatron phase advance between IP 8 and the e-lens. Since this raises $γ_t$ by about one unit, it needs to be ensured that longitudinal matching can still be achieved. In an earlier experiment, $γ_t$ had been lowered by $∆γ_t$ = 0.35 by means of the $γ_t$ quadrupoles. In the experiment reported here, longitudinal matching was achieved by lowering the 9 MHz RF cavity voltage, while $γ_t$ was raised by 0.5 units to more closely simulate the conditions with the higher integer tunes. During the experiment, the Yellow $γ_t$ quad design values were set to the park current (2A), and tunes were adjusted through RampEditor. The 9 MHz RF cavity voltage was reduced from 17 kV to the calculated matched value of 12 kV. Figure 1 shows the resulting beam profile evolution as measured by the wall current monitor (WCM). In an attempt to further fine-tune the matching, the voltage was set to 11.5 and 12.5 kV. However, shot-to-shot fluctuations were larger than the effect of these voltage variations. The Yellow Landau was off during this study, as set through the YellowStore tab in RFramps, as well as in the Landau tab. At the end of the study the Landau settings were restored in the Landau tab to the value as found at the start. The experiment was successful; matching was achieved with around 12 kV on the 9 MHz cavity. Had only one bunch in Yellow during the experiment, but 56 in Blue with the same 9 MHz RF voltage, though unmatched due to regular gamma-t quad settings. No problems due to beam loading at the low cavity voltage occured. This experiment, together with previous studies, indicates that longitudinal matching into the Yellow e-lens lattice can be achieved in spite of the higher horizontal tune.

43 PARTICLE ACCELERATORS↗

Longitudinal matching without $\gamma_t$ quads

The Yellow e-lens lattice requires a different working point (29.68/30.69 instead of 28.68/29.69) to provide the correct betatron phase advance between IP 8 and the e-lens. Since this raises $\gamma_t$ by about one unit, it needs to be ensured that longitudinal matching can still be achieved. In an earlier experiment, $\gamma_t$ had been lowered by$\Delta\gamma_t$ = 0.35 by means of the $\gamma_t$ quadrupoles. In the experiment reported here, longitudinal matching was achieved by lowering the 9 MHz RF cavity voltage, while $\gamma_t$ was raised by 0.5 units to more closely simulate the conditions with the higher integer tunes. During the experiment, the Yellow $\gamma_t$ quad design values were set to the park current (2A), and tunes were adjusted through RampEditor. The 9 MHz RF cavity voltage was reduced from 17 kV to the calculated matched value of 12 kV. Figure 1 shows the resulting beam profile evolution as measured by the wall current monitor (WCM). In an attempt to further fine-tune the matching, the voltage was set to 11.5 and 12.5 kV. However, shot-to-shot fluctuations were larger than the effect of these voltage variations. The Yellow Landau was off during this study, as set through the YellowStore tab in RFramps, as well as in the Landau tab. At the end of the study the Landau settings were restored in the Landau tab to the value as found at the start. The experiment was successful; matching was achieved with around 12 kV on the 9 MHz cavity. Had only one bunch in Yellow during the experiment, but 56 in Blue with the same 9 MHz RF voltage, though unmatched due to regular gamma-t quad settings. No problems due to beam loading at the low cavity voltage occurred. This experiment, together with previous studies , indicates that longitudinal matching into the Yellow e-lens lattice can be achieved in spite of the higher horizontal tune.

43 PARTICLE ACCELERATORS↗

Attempted Transverse Impedance Measurement in RHIC

N/An attempt was made to improve earlier measurements of transverse impedance in RHIC. Measurement with protons at injection were made on March 7, 2012. Data were taken in the yellow ring with the current as a function of time shown in Figure 1. We used the RHICBTF application with varying numbers of bunches. The measured beam transfer functions are shown in Figures 2 and 3. The two indicies parameterizing each curve are the peak current and the number of bunches in the symmetric fill. For the horizontal data in Fig 1 the two blue curves for 8A peak current with 28 bunches have a larger measured tune difference than the green cure with 5A peak current and 6 bunches or the magenta curve with 4A peak current and 28 bunches. The expected tune shift for a transverse impedance of 4MΩ/m and 4 amps is 0.0012. This is comparable to the measured vertical tune shift when changing from 8 to 28 bunches. The RHIC impedance is broadband so any change in tune with bunch number is an instrumental effect. We conclude that another measurement technique is needed to obtain reliable results.

43 PARTICLE ACCELERATORS↗

Attempted Transverse Impedance Measurement in RHIC

An attempt was made to improve earlier measurements of transverse impedance in RHIC. Measurement with protons at injection were made on March 7, 2012. Data were taken in the yellow ring with the current as a function of time shown in Figure 1. We used the RHICBTF application with varying numbers of bunches. The measured beam transfer functions are shown in Figures 2 and 3. The two indices parameterizing each curve are the peak current and the number of bunches in the symmetric fill. For the horizontal data in Fig 1 the two blue curves for 8A peak current with 28 bunches have a larger measured tune difference than the green cure with 5A peak current and 6 bunches or the magenta curve with 4A peak current and 28 bunches. The expected tune shift for a transverse impedance of 4MΩ/m and 4 amps is 0.0012. This is comparable to the measured vertical tune shift when changing from 8 to 28 bunches. The RHIC impedance is broadband so any change in tune with bunch number is an instrumental effect. We conclude that another measurement technique is needed to obtain reliable results.

43 PARTICLE ACCELERATORS↗

Potential for luminosity improvement for low-energy RHIC operation with long bunches

Electron cooling was proposed to increase luminosity of the RHIC collider for heavy ion beams at low energies. Luminosity decreases as the square of bunch intensity due to the beam loss from the RF bucket as a result of the longitudinal intra beam scattering (IBS), as well as due to the transverse emittance growth because of the transverse IBS. Both transverse and longitudinal IBS can be counteracted with electron cooling. This would allow one to keep the initial peak luminosity close to constant throughout the store essentially without the beam loss. In addition, the phase-space density of the hadron beams can be further increased by providing stronger electron cooling. Unfortunately, the defining limitation for low energies in RHIC is expected to be the space charge. Here we explore an idea of additional improvement in luminosity, on top of the one coming from just IBS compensation and longer stores, which may be expected if one can operate with longer bunches at the space-charge limit in a collider. This approach together with electron cooling may result in about 10-fold improvement in total luminosity for low-energy RHIC program.

43 PARTICLE ACCELERATORS↗

Experience with low-energy gold-gold operations in RHIC during FY 2010

During Run-10, RHIC operated at several different Au-Au collision energies, as requested mainly by the STAR collaboration in a quest to search for the critical point in the QGP phase diagram. The center-of-mass energies $\sqrt{s_{NN}}$ are listed in Table 1, together with the respective start and end dates and the duration of the respective run at each energy. While STAR defines “low energy” as anything below $\sqrt{s_{NN}}$ = 39 GeV, we focus in the scope of this paper on energies below the regular RHIC injection energy of $\sqrt{s_{NN}}$ ≈ 20 GeV, since this energy regime is particularly challenging for stable RHIC operations. Figures 1 and 2 show the evolution of beam intensity and luminosity during the course of the $\sqrt{s_{NN}}$ = 7.7 GeV and 11.5 GeV run. In the following sections we will recapitulate the modifications during the run that led to significant performance improvements, and summarize what was learned at the various energies for possible application in future runs.

43 PARTICLE ACCELERATORS↗

A relativistic model of pulsar polarization

The rotating vector model of pulsar polarization of Radhakrishnan and Cooke (1969) is extended here to include first-order special relativistic effects. The model predicts that the centroid of the position angle curve arrives later than the centroid of the intensity profile by 4r/c, where r is the emission radius. Application of the model to pulsars with well ordered position-angle swings and periods between 0.06 and 3.7 s give emission radii of not more than 2000 km for 0.43 and 1.4 GHz. Symmetry-breaking effects of the corotation velocity may help explain a general asymmetry found in pulsar intensity profiles and may strongly affect the intensity profiles of short-period pulsars.

Blaskiewicz, M.↗

Polarization of the binary radio pulsar 1913 + 16 - Constraints on geodetic precession

Using polarization data, the relative orientations of the line of sight and the pulsar's spin axis and magnetic moment are determined. The data are sensitive enough to allow detection of spin-orbit geodetic precession in a few years if the spin axis is misaligned from the orbital angular momentum vector by more than a few degrees. From the secular pulse shape changes measured by Weisberg, et al. (1989) it is concluded that the misalignment angle is no more than 15 deg but is probably more than 1 deg. A specific beaming model is proposed to account for the pulse shape changes.

Cordes, J. M.↗